弥散加权成像与体素内不相干运动鉴别乳腺良恶性病变:系统综述与Meta分析
该系统综述与Meta分析检索2000年1月至2020年4月PubMed和Embase数据库,纳入79项研究共6294例患者(4091个恶性病变、2793个良性病变),评估DWI与IVIM鉴别乳腺良恶性病变的诊断效能。ADC汇总敏感度0.87、特异度0.80、AUC 0.9297;IVIM中D参数表现最佳,汇总敏感度0.85、特异度0.87、AUC 0.9265。作者结论认为DWI和IVIM均有较高敏感度和特异度,但IVIM较DWI未能进一步提高诊断效能,两者诊断准确率无显著差异。
要点
- ADC鉴别乳腺良恶性病变汇总敏感度0.87、特异度0.80、AUC 0.9297。
- IVIM中D参数诊断效能最高,汇总敏感度0.85、特异度0.87、AUC 0.9265。
- IVIM较DWI未能进一步提高诊断效能,两者诊断准确率无显著差异。
核心结论
- DWI和IVIM在乳腺良恶性病变鉴别诊断中具有较高敏感度和特异度;与DWI相比,IVIM未能进一步提高诊断效能,两者诊断准确率无显著差异。
研究设计与样本
- 系统综述与Meta分析,检索PubMed和Embase数据库2000年1月至2020年4月的英文文献,纳入79项报告DWI或IVIM鉴别乳腺良恶性病变敏感度和特异度的研究,共6294例患者(4091个恶性病变、2793个良性病变),采用QUADAS-2进行质量评价,并评估数据异质性和发表偏倚。
诊断标准与关键数值
- ADC检测乳腺恶性肿瘤的汇总敏感度0.87(95%CI 0.86-0.88)、特异度0.80(95%CI 0.78-0.81)、PLR 5.09(95%CI 4.16-6.24)、NLR 0.15(95%CI 0.13-0.18)、DOR 38.95(95%CI 28.87-52.54)、AUC 0.9297。
- IVIM中诊断效能最高的参数为组织弥散系数(D),汇总敏感度0.85(95%CI 0.82-0.88)、特异度0.87(95%CI 0.83-0.90)、PLR 5.65(95%CI 3.91-8.18)、NLR 0.17(95%CI 0.12-0.26)、DOR 38.44(95%CI 23.57-62.69)、AUC 0.9265。
- 多数参数存在显著的统计学异质性(P < 0.05,I²>50%),但D的汇总DOR、D的PLR以及D*的汇总DOR和NLR除外。
临床应用与阅片要点
- 作者认为DWI和IVIM在乳腺良恶性病变鉴别诊断中具有较高敏感度和特异度。
- 作者指出与DWI相比,IVIM未能进一步提高诊断效能,两者诊断准确率无显著差异。
局限性
- 多数参数存在显著的统计学异质性(P < 0.05,I²>50%),但D的汇总DOR、D的PLR以及D*的汇总DOR和NLR除外。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: We sought to evaluate the diagnostic performance of diffusion weighted imaging (DWI) and intravoxel incoherent motion (IVIM) for distinguishing between benign and malignant breast tumors by performing a meta-analysis.
METHODS: We comprehensively searched the electronic databases PubMed and Embase from January 2000 to April 2020 for studies in English. Studies were included if they reported the sensitivity and specificity for identifying benign and malignant breast lesions using DWI or IVIM. Studies were reviewed according to QUADAS-2. The data inhomogeneity and publication bias were also assessed. In order to explore the influence of different field strengths and different b values on diagnostic efficiency, we conducted subgroup analysis.
RESULTS: We analyzed 79 studies, which included a total of 6294 patients with 4091 malignant lesions and 2793 benign lesions. Overall, the pooled sensitivity and specificity of ADC for detecting malignant breast tumors were 0.87 (0.86-0.88) and 0.80 (0.78-0.81), respectively. The PLR was 5.09 (4.16-6.24); the NLR was 0.15 (0.13-0.18); and the DOR was 38.95 (28.87-52.54). The AUC value was 0.9297. The highest performing parameter for IVIM was tissue diffusivity (D), and the pooled sensitivity and specificity was 0.85 (0.82-0.88) and 0.87(0.83-0.90), respectively; the PLR was 5.65 (3.91-8.18); the NLR was 0.17 (0.12-0.26); and the DOR was 38.44 (23.57-62.69). The AUC value was 0.9265. Most of parameters demonstrated considerable statistically significant heterogeneity (P < 0.05, I2>50 %) except the pooled DOR, PLR of D and the pooled DOR and NLR of D*.
CONCLUSIONS: Our meta-analysis indicated that DWI and IVIM had high sensitivity and specificity in the differential diagnosis of breast lesions; and compared with DWI, IVIM could not further increase the diagnostic performance. There was no significant difference in diagnostic accuracy.
引用
- Ma W, Mao J, Wang T, et al. Distinguishing between benign and malignant breast lesions using diffusion weighted imaging and intravoxel incoherent motion: A systematic review and meta-analysis. Eur J Radiol. 2021. PMID: 34116452. doi:10.1016/j.ejrad.2021.109809