该回顾性研究评估了210个乳腺病灶(150个恶性,60个良性),采用超快DCE-MRI序列获取最大斜率(MS),并与常规DCE-MRI半定量曲线比较。MS截断值6.5%/s鉴别良恶性的敏感度和特异度分别为84%和90%,优于半定量曲线的89.3%和55%。MS随BMI增加、绝经后状态和ER阳性而降低,随肿瘤增大而升高,且在预后较差的分子亚型中更高。

要点

  • 超快DCE-MRI最大斜率(MS)以6.5%/s为界鉴别乳腺良恶性,敏感度84%、特异度90%。
  • MS在预后较差的分子亚型(Luminal B+HER2+三阴性)中显著高于Luminal A+ILC组。
  • 以11%/s为阈值识别预后较差侵袭性癌亚型的敏感度71%、特异度68%。

核心结论

  • 最大斜率(MS)可更好地表征肿瘤并识别乳腺癌不良预后因素。

研究设计与样本

  • 回顾性研究,纳入210个乳腺病灶(150个恶性:Luminal A浸润性癌、Luminal B浸润性癌、HER2过表达、三阴性、浸润性小叶癌各30个;60个良性),采用1.5T超快DCE-MRI序列获取MS,常规DCE-MRI半定量曲线分三型,分析MS与年龄、BMI、绝经状态及常规预后因素的相关性。

诊断标准与关键数值

  • MS截断值6.5%/s鉴别良恶性病灶:敏感度84%,特异度90%。
  • 常规DCE-MRI半定量曲线分析鉴别良恶性:敏感度89.3%,特异度55%。
  • MS阈值11%/s识别预后较差的浸润性癌亚型:敏感度71%,特异度68%。

临床应用与阅片要点

  • 超快DCE-MRI的MS较常规半定量曲线能更好地区分乳腺良恶性病灶。
  • MS可用于识别预后较差的乳腺癌亚型,多发病灶时可测量MS targeting最具侵袭性的病灶。
  • MS值随BMI增加、绝经后状态和ER阳性而降低,随肿瘤增大而升高。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: We evaluated the relationship between the maximum slope (MS) based on ultrafast breast DCE-MRI sequences, and the clinical parameters and routine prognostic factors of breast cancer.

METHODS: 210 lesions were retrospectively evaluated: 150 malignant (30 each of luminal A invasive carcinoma, luminal B invasive carcinoma, HER2 overexpression (HER2), triple negative (TN), invasive lobular carcinoma (ILC)), and 60 benign. For each lesion, the MS was obtained with an ultrafast sequence and semi-quantitative curves were classified into three types with a conventional DCE sequence. The correlation between MS and age, body mass index (BMI), menopause, and routine prognostic factors were analyzed.

RESULTS: A MS cut-off at 6.5%/s could discriminate benign from malignant lesions, with sensitivity and specificity of 84% and 90%, respectively, whereas analysis of semi-quantitative curves showed sensitivity and specificity of 89.3% and 55%, respectively. In multivariate analysis, MS values decreased with BMI increasing (p = 0.035), postmenopausal status (p < 0.001), and positive ER status (p < 0.001) and increased with tumor size (p < 0.001). The MS was significantly lower for the pooled luminal A + ILC group than for the pooled luminal B + HER2 + TN group featuring tumors with poorer prognoses (p < 0.001). With a threshold of 11%/s, the sensitivity and specificity to identify invasive carcinoma subtypes with poorer prognoses were 71% and 68%, respectively.

CONCLUSION: The MS allows better tumor characterization and identifies factors of poor prognosis for breast cancer.

KEY POINTS: • Maximum slope calculated from ultrafast breast DCE-MRI differentiates benign from malignant breast lesions better than semi-quantitative curves of conventional DCE-MRI. • Maximum slope calculated from ultrafast breast DCE-MRI identifies breast cancers with poor prognoses. • In the case of multiple lesions, the most aggressive may be identified and targeted by measuring the maximum slope.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Pelissier M, Ambarki K, Salleron J, et al. Maximum slope using ultrafast breast DCE-MRI at 1.5 Tesla: a potential tool for predicting breast lesion aggressiveness. Eur Radiol. 2021. PMID: 34117556. doi:10.1007/s00330-021-08089-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。