文献速递乳腺US

常规超声与超声造影检测的乳腺乳头状病变:影像特征及其与恶性的关联

Papillary breast lesions detected using conventional ultrasound and contrast-enhanced ultrasound: Imaging characteristics and associations with malignancy.
PubMed 文献 · Eur J Radiol · 2021-05-23

该回顾性研究评估了74个连续乳腺乳头状病变的常规超声与超声造影特征,并与病理结果对照。常规超声的病灶大小≥1 cm和边缘不光整,以及超声造影的不规则增强、不均匀增强、范围增大和灌注缺损在良性与不典型或恶性乳头状病变间有显著差异。多因素分析显示仅不均匀增强和增强范围增大与恶性相关,两者联合诊断准确率AUC=0.875。

要点

  • 超声造影不均匀增强和范围增大与乳头状病变恶性独立相关,两者联合AUC=0.875。
  • 常规超声病灶≥1 cm及边缘不光整在良恶性乳头状病变间差异有统计学意义。
  • 超声造影灌注缺损、不规则增强也与恶性相关,但多因素分析仅上述两项独立关联。

核心结论

  • 常规超声与超声造影影像特征有助于鉴别良性与恶性乳头状病变并预测其恶性潜能。

研究设计与样本

  • 回顾性分析74个连续乳腺乳头状病变的常规超声和超声造影表现,以病理为参考标准,采用单因素和多因素logistic回归评估各参数及联合参数鉴别良性与不典型或恶性病变的能力。

关键影像表现/征象

  • 常规超声:病灶大小≥1 cm和边缘不光整在良性与不典型或恶性乳头状病变间差异有统计学意义(P<0.05)。
  • 超声造影:不规则增强、不均匀增强、增强范围增大和灌注缺损在良性与不典型或恶性乳头状病变间差异有统计学意义(P<0.05)。
  • 多因素logistic回归显示仅不均匀增强和增强范围增大与恶性相关。

诊断标准与关键数值

  • 不均匀增强预测不典型和恶性乳头状病变的敏感度78.6%、特异度39.1%。
  • 增强范围增大预测不典型和恶性乳头状病变的敏感度75%、特异度37%。
  • 不均匀增强与增强范围增大联合分析的敏感度75%、特异度82.6%,AUC=0.875。

临床应用与阅片要点

  • 阅片时可关注超声造影不均匀增强和增强范围增大,两者联合有助于提示乳头状病变的恶性风险。
  • 常规超声病灶≥1 cm和边缘不光整可作为提示不典型或恶性乳头状病变的参考征象。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: This study aimed to evaluate the imaging features of papillary breast lesions detected using conventional ultrasonography (US) and contrast-enhanced ultrasound (CEUS) and to correlate the pathological results. Furthermore, the diagnostic efficiencies of these imaging features to predict the malignancy potential of papillary lesions were explored.

METHODS: The findings of the conventional US and CEUS of 74 consecutive papillary breast lesions were assessed retrospectively. The obtained data were analyzed using univariate and multivariate logistic regressions to evaluate the ability of each parameter and combined parameters in distinguishing the benign and atypical or malignant papillary lesions.

RESULTS: Among the imaging features of breast papillary lesions on conventional US and CEUS, two sonographic features (lesion size ≥1 cm and not circumscribed margin) on conventional US and four enhancement features (irregular enhancement, heterogeneous enhancement, enlargement of scope, and perfusion defect) on CEUS were found to be significantly different between the benign and atypical or malignant papillary lesions (P < 0.05). A multivariate logistic regression analysis further showed that only heterogeneous enhancement and enlarged enhancement scope were associated with malignancy. The sensitivity and specificity of heterogeneous enhancement, enlarged enhancement scope, and combined analysis for predicting atypical and malignant papillary lesions were 78.6 % and 39.1 %, 75 % and 37 %, and 75 % and 82.6 %, respectively. The combination of enhancement homogeneity and enhancement scope improved the diagnostic accuracy (AUC = 0.875).

CONCLUSIONS: The results suggested that the imaging features on conventional US and CEUS could help in identifying benign and malignant papillary lesions and predict their malignancy potential.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Niu RL, Li SY, Wang B, et al. Papillary breast lesions detected using conventional ultrasound and contrast-enhanced ultrasound: Imaging characteristics and associations with malignancy. Eur J Radiol. 2021. PMID: 34091133. doi:10.1016/j.ejrad.2021.109788

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。