文献速递乳腺US乳腺X线

二维剪切波弹性成像对乳腺X线摄影可疑微钙化的特征分析

Characterization of Suspicious Microcalcifications on Mammography Using 2D Shear-Wave Elastography.
PubMed 文献 · Ultrasound Med Biol · 2021-06-11

本研究评估50例乳腺X线摄影发现可疑微钙化且超声可见、不伴肿块的患者的二维剪切波弹性成像(2D-SWE)表现,并与超声引导下粗针活检病理对照。恶性与良性微钙化的SWE值差异有统计学意义(p < 0.001);SWE鉴别恶性、浸润性和高级别的敏感度分别为93%、83%、88%,特异度分别为91%、88%、53%,AUC分别为0.952、0.885、0.776, cut-off值分别为57 kPa、124 kPa、124.5 kPa。作者认为SWE是临床实践中表征超声可见微钙化的有用方法。

要点

  • 对超声可见的可疑微钙化,2D-SWE鉴别良恶性的AUC达0.952, cut-off值57 kPa。
  • SWE鉴别浸润性的敏感度83%、特异度88%,AUC 0.885, cut-off值124 kPa。
  • SWE鉴别高级别的特异度仅53%,AUC 0.776, cut-off值124.5 kPa。

核心结论

  • SWE是临床实践中表征超声可见微钙化的有用方法。

研究设计与样本

  • 共纳入50例(原文未写明中心数)乳腺X线摄影发现可疑微钙化且超声可见、不伴肿块的患者,于超声引导下粗针活检前接受超声和2D-SWE检查,SWE值与组织病理学特征进行统计学比较;组间变量采用Mann-Whitney U检验,行受试者工作特征分析并确定cut-off值以区分恶性、浸润性和高级别。

诊断标准与关键数值

  • 病理证实27个恶性病变(18个浸润性导管癌、1个浸润性小叶癌、8个导管原位癌)和23个良性病变;恶性与良性微钙化的SWE值差异有统计学意义(p < 0.001);SWE鉴别恶性、浸润性和高级别的敏感度分别为93%、83%、88%,特异度分别为91%、88%、53%,阳性预测值分别为93%、94%、44%,阴性预测值分别为91%、70%、90%,AUC分别为0.952、0.885、0.776,cut-off值分别为57 kPa、124 kPa、124.5 kPa。

临床应用与阅片要点

  • 作者认为SWE是临床实践中表征超声可见微钙化的有用方法;原文未据此给出具体阅片或报告建议。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Our aim was to investigate the correlations between the findings of two-dimensional shear-wave elastography (2D-SWE) and the histopathologic results of microcalcifications (MCs) visualized using ultrasonography (USG). Fifty people with suspicious MCs without accompanying mass were evaluated. They underwent USG and 2D-SWE before USG-guided tru-cut biopsy. SWE values and histopathologic features were compared statistically. The variables between groups were analyzed using the Mann-Whitney U test. Receiver operating characteristic analysis was performed and cut-off values determined to discriminate malignancy, invasiveness and high grade. Pathology confirmed 27 malignant lesions (18 invasive ductal carcinomas, one invasive lobular and eight ductal carcinomas in situ) and 23 benign ones. There was a statistically significant difference between the SWE values of malignant and benign MCs (p < 0.001). The diagnostic performance of SWE for malignancy, invasiveness and high grade were as follows, repectively: sensitivity (93%, 83%, 88%), specificity (91%, 88%, 53%), positive predictive value (93%, 94%, 44%), negative predictive value (91%, 70%, 90%) and area under the curve (0.952, 0.885, 0.776). Cut-off values were determined as 57 kPa for malignancy, 124 kPa for invasiveness and 124.5 kPa for high grade. In conclusion, SWE is a useful method in clinical practice for characterizing MCs that can be visualized with USG.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Kayadibi Y, Ucar N, Kaya MF, et al. Characterization of Suspicious Microcalcifications on Mammography Using 2D Shear-Wave Elastography. Ultrasound Med Biol. 2021. PMID: 34127332. doi:10.1016/j.ultrasmedbio.2021.05.008

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。