乳腺淋巴超声造影评估乳腺癌患者全腋窝状态
本研究对169例疑似乳腺癌患者行淋巴超声造影(LCEUS),以淋巴管异常、前哨淋巴结充盈缺损及非增强异常淋巴结为腋窝转移征象;在157例有腋窝清扫的乳腺癌患者中,LCEUS评估全腋窝的敏感度76.5%、特异度86.5%、准确率82.2%,均高于常规超声和仅评估前哨淋巴结的LCEUS。
要点
- LCEUS评估全腋窝的准确率82.2%,高于常规超声70.7%及仅评估前哨淋巴结79.6%。
- 腋窝转移征象包括淋巴管扭曲、变细、网状或中断,前哨淋巴结充盈缺损或无充盈,以及非增强异常淋巴结。
- 任一异常征象出现即判为LCEUS阳性。
核心结论
- LCEUS可作为观察乳腺癌患者全腋窝的准确方法,淋巴管、前哨淋巴结及非增强异常淋巴结构成全腋窝评估的三方面。
研究设计与样本
- 对169例疑似乳腺癌患者行LCEUS,其中157例乳腺癌患者成功完成LCEUS并接受腋窝清扫。
关键影像表现/征象
- 淋巴管异常表现为扭曲、变细、网状或中断。
- 前哨淋巴结异常表现为充盈缺损或无充盈。
- 非增强但异常的淋巴结出现。
- 上述异常征象在转移性腋窝中的出现频率显著高于正常腋窝(p=0.000)。
诊断标准与关键数值
- 常规超声评估全腋窝:敏感度69.1%、特异度71.9%、准确率70.7%。
- LCEUS评估前哨淋巴结预测全腋窝:敏感度66.2%、特异度89.9%、准确率79.6%。
- LCEUS评估全腋窝:敏感度76.5%、特异度86.5%、准确率82.2%。
- 任一异常征象(淋巴管扭曲、变细、网状或中断,前哨淋巴结充盈缺损或无充盈,非增强异常淋巴结)出现即判定为LCEUS阳性。
临床应用与阅片要点
- LCEUS可同时观察淋巴管、前哨淋巴结及非增强异常淋巴结,用于评估全腋窝状态。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: This study aims to evaluate the whole axillary status of patients with breast cancer by lymphatic contrast-enhanced ultrasound (LCEUS).
METHODS: LCEUS was applied for 169 patients with suspected breast cancer. Abnormal patterns in lymphatic channels, sentinel lymph nodes (SLNs), and non-enhanced but abnormal lymph nodes were investigated. The signs of distorted, attenuated, netted, or interrupted lymphatic channels, defective-filling or no-filling SLNs, and the appearance of non-enhanced but abnormal lymph nodes were designated as features of axillary metastasis. A positive outcome was given when any of the abnormal patterns was found in the LCEUS. The diagnostic efficiencies were calculated to differentiate the axillary lymphatic status using LCEUS for the whole axilla, compared with conventional ultrasound (US) and LCEUS for SLNs.
RESULTS: The LCEUS procedure was successfully performed for 157 breast cancer patients with axillary dissection. Compared to normal axillae, abnormal patterns had a significantly higher frequency in metastatic axillae (p = 0.000). Using conventional US to evaluate the whole axillae, the diagnostic sensitivity, specificity, and accuracy were 69.1%, 71.9%, and 70.7%, respectively. When LCEUS was used for SLN evaluation to predict the whole axilla, the diagnostic sensitivity, specificity, and accuracy were 66.2%, 89.9%, and 79.6%, respectively. When LCEUS was used as the whole axillary evaluation method, the diagnostic sensitivity, specificity, and accuracy were 76.5%, 86.5%, and 82.2%, respectively.
CONCLUSION: LCEUS can be an accurate method to observe the whole axillae in breast cancer patients. Lymphatic channels, SLNs, and non-enhanced but abnormal lymph nodes constitute the LCEUS for whole axillary evaluation.
KEY POINTS: • LCEUS can be an accurate method to observe the whole axillae in breast cancer patients. • Three aspects in the LCEUS for whole axillary evaluation are the lymphatic channels, sentinel lymph nodes (SLNs), and non-enhanced but abnormal lymph nodes. • Signs of distorted, attenuated, netted, or interrupted lymphatic channels, defective-filling or no-filling SLNs, and the appearance of non-enhanced but abnormal lymph nodes were considered as features of axillary metastasis.
引用
- Jin L, Wang R, Zhuang L, et al. Evaluation of whole axillary status with lymphatic contrast-enhanced ultrasound in patients with breast cancer. Eur Radiol. 2021. PMID: 34165620. doi:10.1007/s00330-021-08100-8
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。