基于容积ADC直方图分析术前评估I期子宫内膜样腺癌淋巴血管间隙浸润状态
回顾性分析227例I期子宫内膜样腺癌患者的术前MRI,从全肿瘤DWI所有层面勾画ROI提取ADC直方图参数。LVSI阳性组minADC、meanADC及第10、25、50、75、90百分位ADC显著低于LVSI阴性组(均p<0.05);meanADC≤0.857×10⁻³ mm²/s评估I期LVSI的AUC为0.844,敏感度75.4%、特异度80.0%、准确率79.3%。作者认为容积ADC直方图可能有助于术前评估LVSI状态。
要点
- LVSI阳性者minADC、meanADC及多个ADC百分位数显著低于LVSI阴性者(均p<0.05)。
- meanADC≤0.857×10⁻³ mm²/s评估I期LVSI的AUC为0.844。
- I期与Ia期以meanADC、Ib期以ADC第90百分位评估LVSI的AUC最大。
核心结论
- 容积ADC直方图参数可能有助于I期子宫内膜样腺癌患者LVSI状态的术前评估和个体化临床管理。
研究设计与样本
- 回顾性分析227例I期子宫内膜样腺癌患者的术前MRI,在DWI(b=0、1000 s/mm²)所有层面勾画ROI提取全肿瘤ADC直方图参数。
关键影像表现/征象
- LVSI阳性EAC的minADC、meanADC及第10、25、50、75、90百分位ADC在I期、Ia期和Ib期均显著低于LVSI阴性组(均p<0.05)。
诊断标准与关键数值
- 评估I期LVSI:meanADC≤0.857×10⁻³ mm²/s时AUC 0.844,敏感度75.4%,特异度80.0%,准确率79.3%。
- 评估Ia期LVSI:meanADC≤0.854×10⁻³ mm²/s时AUC 0.844,敏感度75.0%,特异度83.1%,准确率81.5%。
- 评估Ib期LVSI:ADC第90百分位≤1.06×10⁻³ mm²/s时AUC 0.849,敏感度76.2%,特异度82.1%,准确率79.6%。
临床应用与阅片要点
- 作者认为容积ADC直方图参数可能有助于I期EAC患者LVSI状态的术前评估和个体化临床管理。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To investigate the value of volumetric ADC histogram metrics for evaluating lymphovascular space invasion (LVSI) status in stage I endometrioid adenocarcinoma (EAC).
METHODS: Preoperative MRI of 227 patients with stage I EAC were retrospectively analyzed. ADC histogram data were derived from the whole tumor with ROIs drawn on all slices of DWI scans (b = 0, 1000 s/mm2). The Student t-test was performed to compare ADC histogram metrics (minADC, maxADC, and meanADC; 10th, 25th, 50th, 75th, and 90th percentiles of ADC; skewness; and kurtosis) between the LVSI-positive and LVSI-negative groups, as well as between stage Ia and Ib EACs. ROC curve analysis was carried out to evaluate the diagnostic performance of ADC histogram metrics in predicting LVSI status in EAC.
RESULTS: The minADC and meanADC and 10th, 25th, 50th, 75th, and 90th percentiles of ADC were significantly lower in LVSI-positive EACs compared with those in the LVSI-negative groups for stage I, Ia, and Ib EACs (all p < 0.05). MeanADC ≤ 0.857 × 10-3 mm2/s, meanADC ≤ 0.854 × 10-3 mm2/s, and the 90th percentile of ADC ≤ 1.06 × 10-3 mm2/s yielded the largest AUC of 0.844, 0.844, and 0.849 for evaluating LVSI positivity in stage I, Ia, and Ib tumors, respectively, with sensitivity of 75.4%, 75.0%, and 76.2%; specificity of 80.0%, 83.1%, and 82.1%; and accuracy of 79.3%, 81.5%, and 79.6%, respectively.
CONCLUSION: Volumetric ADC histogram metrics might be helpful for the preoperative evaluation of LVSI status and personalized clinical management in patients with stage I EAC.
KEY POINTS: • Volumetric ADC histogram analysis helps evaluate LVSI status preoperatively. • LVSI-positive EAC is associated with a reduction in multiple volumetric ADC histogram metrics. • MeanADC and the 90th percentile of ADC were shown to be best in evaluating LVSI- positivity in stage Ia and Ib EACs, respectively.
引用
- Ma X, Ren X, Shen M, et al. Volumetric ADC histogram analysis for preoperative evaluation of LVSI status in stage I endometrioid adenocarcinoma. Eur Radiol. 2021. PMID: 34137929. doi:10.1007/s00330-021-07996-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。