文献速递妇产影像腹部US

经阴道超声诊断累及子宫骶韧带、子宫颈后方及阴道后穹窿的深部子宫内膜异位症:前瞻性研究

Transvaginal ultrasound for diagnosis of deep endometriosis involving uterosacral ligaments, torus uterinus and posterior vaginal fornix: prospective study.
PubMed 文献 · Ultrasound Obstet Gynecol · 2021-11-09

该前瞻性研究纳入172例临床疑似盆腔子宫内膜异位症并计划行腹腔镜手术的女性,术前经阴道超声(TVS)诊断累及子宫骶韧带(USLs)、子宫颈后方(TU)或阴道后穹窿(PVF)的深部子宫内膜异位症(DE),并与腹腔镜及组织学结果对照。TVS诊断USLs、TU和/或PVF受累的总体敏感度为92%、特异度为87%;USLs、TU、PVF各自准确度分别为89.5%、86.6%、93.6%。TVS诊断USLs、TU和/或PVF受累与直肠乙状结肠DE显著相关(OR 5.43,P<0.001)。

要点

  • TVS诊断USLs、TU和/或PVF受累的总体敏感度92%、特异度87%,准确度较高。
  • USLs受累的TVS敏感度96.6%、特异度82.1%,NPV 95.8%,阳性似然比5.41。
  • PVF受累的TVS特异度94.6%、阳性似然比16.20,但PPV仅71.4%。

核心结论

  • TVS对疑似子宫内膜异位症并计划腹腔镜手术的女性中累及USLs、TU和PVF的DE具有高准确度、敏感度、特异度、PPV和NPV。

研究设计与样本

  • 前瞻性研究,连续纳入172例临床疑似盆腔子宫内膜异位症并计划行腹腔镜手术的女性,术前行TVS,与腹腔镜及组织学确诊结果对照。

诊断标准与关键数值

  • TVS诊断DE累及USLs、TU和/或PVF的总体敏感度92%、特异度87%。
  • USLs受累:准确度89.5%、敏感度96.6%、特异度82.1%、PPV 85.0%、NPV 95.8%、阳性似然比5.41、阴性似然比0.04。
  • TU受累:准确度86.6%、敏感度83.9%、特异度89.4%、PPV 89.0%、NPV 84.4%、阳性似然比7.92、阴性似然比0.18。
  • PVF受累:准确度93.6%、敏感度87.0%、特异度94.6%、PPV 71.4%、NPV 97.9%、阳性似然比16.20、阴性似然比0.14。

临床应用与阅片要点

  • TVS发现USLs、TU和/或PVF受累时,需注意合并直肠乙状结肠DE的可能(OR 5.43,P<0.001)。
  • 排便困难与USLs、TU和PVF受累强烈相关,痛经与TU受累显著相关。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To evaluate the accuracy of transvaginal ultrasound (TVS) in diagnosing deep endometriosis (DE) involving the uterosacral ligaments (USLs), torus uterinus (TU) or posterior vaginal fornix (PVF) in women with suspected endometriosis scheduled for laparoscopic surgery.

METHODS: In this prospective study, consecutive women with clinically suspected pelvic endometriosis who were scheduled for laparoscopic surgery were invited to participate. TVS was performed before surgery. TVS findings were compared with those obtained at laparoscopy and confirmed histologically. The accuracy of TVS for diagnosing DE involving the USLs, TU or PVF was assessed. Additionally, the association of DE involving the USLs, TU or PVF on TVS with symptoms and with DE affecting other pelvic locations was assessed.

RESULTS: In total, 172 patients were included. The global sensitivity and specificity of TVS in diagnosing DE affecting the USLs, TU and/or PVF were 92% and 87%, respectively. For DE involving the USLs, the accuracy, sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), positive likelihood ratio and negative likelihood ratio of TVS were 89.5%, 96.6%, 82.1%, 85.0%, 95.8%, 5.41 and 0.04, respectively; the respective values for DE involving the TU were 86.6%, 83.9%, 89.4%, 89.0%, 84.4%, 7.92 and 0.18, and the respective values for DE involving the PVF were 93.6%, 87.0%, 94.6%, 71.4%, 97.9%, 16.20 and 0.14. Logistic regression analysis showed a significant association between DE affecting the USLs, TU and/or PVF and DE affecting the rectosigmoid (odds ratio, 5.43; P < 0.001). Dyschezia was associated strongly with DE involving the USLs, TU and PVF, while dysmenorrhea was associated significantly with DE involving the TU.

CONCLUSION: TVS has high accuracy, sensitivity, specificity, PPV and NPV for the detection of DE involving the USLs, TU and PVF in women with suspected endometriosis scheduled for laparoscopic surgery. © 2021 International Society of Ultrasound in Obstetrics and Gynecology.

来源:Ultrasound Obstet Gynecol,查看原文。版权归原作者所有。

引用

  1. Ros C, de Guirior C, Mension E, et al. Transvaginal ultrasound for diagnosis of deep endometriosis involving uterosacral ligaments, torus uterinus and posterior vaginal fornix: prospective study. Ultrasound Obstet Gynecol. 2021. PMID: 34090310. doi:10.1002/uog.23696

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。