双能CT常规临床参数与儿童尿路结石体外冲击波碎石术结局的相关性研究:一项回顾性研究
该回顾性研究纳入2011—2019年在本院接受体外冲击波碎石术(ESWL)并行双能CT(DECT)的207例连续结石患儿,评估DECT参数与ESWL结局的相关性。结果显示140 kVp、80 kVp、120 kVp下CT衰减值和有效原子序数(Zeff)与结石清除(SF)和结石残留(RS)状态显著相关(P<0.05)。120 kVp、80 kVp、140 kVp下CT衰减值和双能指数(DEI)的AUC分别为0.784、0.780、0.766和0.709(均P<0.05)。作者结论认为DECT参数可用于预测儿童尿路结石的ESWL结局(尤其是SF状态),ESWL成功可被DECT准确预测,而ESWL失败难以预测。
要点
- DECT的140 kVp、80 kVp、120 kVp下CT衰减值和Zeff与儿童ESWL后结石清除和残留状态显著相关(P<0.05)。
- 120 kVp、80 kVp、140 kVp下CT衰减值和DEI预测ESWL结局的AUC分别为0.784、0.780、0.766和0.709(均P<0.05)。
- 以140 kVp、80 kVp、120 kVp下CT衰减值和DEI的截断值分别为882.5、1330.5、1042.5和0.103时,敏感度分别为75.0%、83.3%、80.3%和58.3%,特异度分别为31.1%、31.8%、31.1%和44.7%。
核心结论
- DECT参数可用于预测儿童尿路结石的ESWL结局,尤其是结石清除状态。
- ESWL成功可被DECT准确预测,而ESWL失败难以预测。
研究设计与样本
- 回顾性研究,纳入2011—2019年在本院连续接受ESWL和DECT的结石患儿207例。
- 主要结局为DECT影像与ESWL结局的相关性;次要结局为确定独立预测ESWL结局(结石清除和结石残留状态)的DECT参数。
诊断标准与关键数值
- 140 kVp、80 kVp、120 kVp下CT衰减值和有效原子序数(Zeff)与结石清除和结石残留状态显著相关(P<0.05)。
- 120 kVp下CT衰减值预测ESWL结局的AUC为0.784(95% CI 0.672-0.897),80 kVp下CT衰减值为0.780(95% CI 0.677-0.884),140 kVp下CT衰减值为0.766(95% CI 0.658-0.885),DEI为0.709(95% CI 0.578-0.840),均P<0.05。
- 以140 kVp下CT衰减值截断值882.5预测ESWL结局,敏感度75.0%、特异度31.1%。
- 以80 kVp下CT衰减值截断值1330.5预测ESWL结局,敏感度83.3%、特异度31.8%。
- 以120 kVp下CT衰减值截断值1042.5预测ESWL结局,敏感度80.3%、特异度31.1%。
临床应用与阅片要点
- DECT参数可用于预测儿童尿路结石的ESWL结局,尤其是结石清除状态。
- ESWL成功可被DECT准确预测,而ESWL失败难以预测。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the associations of DECT parameters with extracorporeal shock wave lithotripsy (ESWL) outcomes in pediatric patients.
METHODS: A retrospective study of consecutive patients with calculi who underwent ESWL and DECT in our hospital was performed in 2011-2019. The primary outcome was DECT imaging's correlation with ESWL outcomes. The secondary outcome was to determine DECT parameters independently predicting ESWL outcomes, including stone-free (SF) and residual stone (RS) statuses.
RESULTS: The study included 207 patients. The mean CT attenuations at 140 kVp, 80 kVp, and 120 kVp and effective atomic number (Zeff) were significantly correlated with stone free (SF) and residual stone (RS) (P < 0.05). Areas under the curves (AUCs) of CT attenuations at 120 kVp, 80 kVp, 140 kVp, and dual-energy index (DEI) were 0.784 (95% CI 0.672-0.897), 0.780 (95% CI 0.677-0.884), 0.766 (95% CI 0.658-0.885), and 0.709 (95% CI 0.578-0.840) (all P < 0.05). With cutoffs of 882.5, 1330.5, 1042.5, and 0.103 for CT attenuations at 140 kVp, 80 kVp, 120 kVp, and DEI, respectively, sensitivities and specificities were 75.0% and 31.1%, 83.3% and 31.8%, 80.3% and 31.1%, and 58.3% and 44.7%, respectively.
CONCLUSION: Our results demonstrated that the parameters of DECT could be used to predict ESWL outcomes (especially the SF status) in children with urolithiasis. ESWL success can be accurately predicted by DECT, and it is hard to predict ESWL failure.
引用
- Tu B, Jia J, Yu L, et al. Correlative investigation between routine clinical parameters of dual-energy computed tomography and the outcomes of extracorporeal shock wave lithotripsy in children with urolithiasis: a retrospective study. Abdom Radiol (NY). 2021. PMID: 34114086. doi:10.1007/s00261-021-03162-0