肾结石CT辐射剂量降低:一项随机、基于设施的干预研究
该研究将2015年向美国放射学会剂量指数登记处贡献至少40例肾结石CT的设施随机分为干预组和对照组,干预包括定制CME模块、个性化咨询和低剂量CT方案推荐。结果显示,参与干预的设施平均剂量长度乘积从2015年到2017年下降110 mGy·cm(降低16%),显著低于对照组(P < .05),且低剂量CT比例在3年内均高于其他组(P < .01)。
要点
- 参与干预的设施肾结石CT平均DLP降低110 mGy·cm(16%),显著低于对照组。
- 参与干预的设施低剂量CT比例在2017、2018、2019年均高于其他组。
- 干预效果在参与设施中持续存在。
核心结论
- 针对肾结石CT的剂量优化干预在参与设施中实现了显著且持续的平均辐射剂量降低。
研究设计与样本
- 随机、基于设施的干预研究;314家合格设施随机分为干预组155家和对照组159家,最终参与干预的设施25家、随机到干预但未参与的设施71家、对照设施96家;以美国放射学会剂量指数登记处记录的剂量长度乘积为指标,比较2015年基线与此后2017、2018、2019年。
诊断标准与关键数值
- 参与干预的设施平均DLP从2015年到2017年下降110 mGy·cm,相当于降低16%,显著低于对照组(P < .05)。
- 参与干预的设施低剂量CT比例在2017、2018、2019年每一年均高于其他组(P < .01)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Kidney stones are common, tend to recur, and afflict a young population. Despite evidence and recommendations, adoption of reduced-radiation dose CT (RDCT) for kidney stone CT (KSCT) is slow. We sought to design and test an intervention to improve adoption of RDCT protocols for KSCT using a randomized facility-based intervention.
METHODS: Facilities contributing at least 40 KSCTs to the American College of Radiology dose index registry (DIR) during calendar year 2015 were randomized to intervention or control groups. The Dose Optimization for Stone Evaluation intervention included customized CME modules, personalized consultation, and protocol recommendations for RDCT. Dose length product (DLP) of all KSCTs was recorded at baseline (2015) and compared with 2017, 2018, and 2019. Change in mean DLP was compared between facilities that participated (intervened-on), facilities randomized to intervention that did not participate (intervened-off), and control facilities. Difference-in-difference between intervened-on and control facilities is reported before and after intervention.
RESULTS: Of 314 eligible facilities, 155 were randomized to intervention and 159 to control. There were 25 intervened-on facilities, 71 intervened-off facilities, and 96 control facilities. From 2015 to 2017, there was a drop of 110 mGy ∙ cm (a 16% reduction) in the mean DLP in the intervened-on group, which was significantly lower compared with the control group (P < .05). The proportion of RDCTs increased for each year in the intervened-on group relative to the other groups for all 3 years (P < .01).
DISCUSSION: The Dose Optimization for Stone Evaluation intervention resulted in a significant (P < .05) and persistent reduction in mean radiation doses for engaged facilities performing KSCTs.
引用
- Moore CL, Bhargavan-Chatfield M, Shaw MM, et al. Radiation Dose Reduction in Kidney Stone CT: A Randomized, Facility-Based Intervention. J Am Coll Radiol. 2021. PMID: 34115990. doi:10.1016/j.jacr.2021.05.004
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。