影响爆发波碎石术中组织空化因素的研究
本研究在八只猪的肾脏中经皮暴露于爆发波碎石超声脉冲,测量体内组织空化所需的焦点压力振幅,并评估其在天然组织、植入结石模型及不同暴露参数下的一致性。结果表明,结石或假手术的存在未显著影响组织空化阈值;靶向肾实质而非肾集合空间以及降低超声脉冲重复频率均导致空化压力阈值升高。
要点
- 植入结石或假手术未显著影响组织空化阈值。
- 靶向肾实质较靶向肾集合空间使空化压力阈值升高。
- 降低超声脉冲重复频率使空化压力阈值升高。
核心结论
- 结石或假手术的存在未显著影响组织空化阈值;靶向肾实质而非肾集合空间以及降低超声脉冲重复频率均使空化压力阈值升高。
研究设计与样本
- 研究在八只猪的肾脏中进行,经皮暴露于爆发波碎石超声脉冲,每个肾脏靶向肾窦和肾实质两个位置,各以设定压力水平和参数暴露5分钟,采用基于能量多普勒超声的主动空化成像方法检测空化,通过每5分钟间隔上调或下调压力振幅直至空化发生或消退来确定阈值,术后针对植入结石或集合空间(假手术)重新测量压力阈值。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Burst wave lithotripsy (BWL) is a technology under clinical investigation for non-invasive fragmentation of urinary stones. Under certain ranges of ultrasound exposure parameters, this technology can cause cavitation in tissue leading to renal injury. This study sought to measure the focal pressure amplitude needed to cause cavitation in vivo and determine its consistency in native tissue, in an implanted stone model and under different exposure parameters. The kidneys of eight pigs were exposed to transcutaneous BWL ultrasound pulses. In each kidney, two locations were targeted: the renal sinus and the kidney parenchyma. Each was exposed for 5 min at a set pressure level and parameters, and cavitation was detected using an active cavitation imaging method based on power Doppler ultrasound. The threshold was determined by incrementing the pressure amplitude up or down after each 5-min interval until cavitation occurred/subsided. The pressure thresholds were remeasured postsurgery, targeting an implanted stone or collecting space (in sham). The presence of a stone or sham surgery did not significantly impact the threshold for tissue cavitation. Targeting parenchyma instead of kidney collecting space and lowering the ultrasound pulse repetition frequency both resulted in an increased pressure threshold for cavitation.
引用
- Maxwell AD, Hunter C, Cunitz BW, et al. Factors Affecting Tissue Cavitation during Burst Wave Lithotripsy. Ultrasound Med Biol. 2021. PMID: 34078545. doi:10.1016/j.ultrasmedbio.2021.04.021
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。