呼吸触发单扩散敏感梯度扩散加权成像缩短采集时间——肝细胞癌检查中的可行性研究
这项前瞻性研究纳入48例慢性肝病患者,在1.5 T扫描仪上比较单向扩散加权成像(u-SSEPI)与常规四方向扩散加权成像(4t-SSEPI)的ADC值及诊断准确性。u-SSEPI采集速度提高3倍,两者图像质量、病灶检出率及ADC值无显著差异,鉴别肝细胞癌的AUC亦无统计学差异。
要点
- 单向扩散加权成像采集速度提高3倍,图像质量与病灶检出率与常规序列无显著差异。
- 两种序列病灶ADC值差异无统计学意义(p=0.8),变异系数12-14%。
- 以ADC鉴别肝细胞癌的AUC在常规DWI为0.63(观察者1)和0.62(观察者2),单向DWI为0.65和0.62,无统计学差异。
核心结论
- 单向扩散加权成像与常规扩散加权成像在肝细胞癌诊断准确性上无显著差异,单向扩散可能可用于扩散各向同性的其他器官,尤其在呼吸触发序列中节省时间显著。
研究设计与样本
- 前瞻性、经IRB批准的研究,纳入48例慢性肝病患者,在1.5 T扫描仪上行DCE-MRI进行肝细胞癌检查,比较4t-SSEPI与u-SSEPI序列,以DCE-MRI、随访影像和临床资料建立复合金标准。
关键影像表现/征象
- u-SSEPI仅在一个方向施加扩散敏感梯度,其余参数与4t-SSEPI相同。
- 两种序列的图像质量参数和病灶检出率无统计学显著差异。
诊断标准与关键数值
- 复合金标准共识别88个病灶。
- 病灶ADC值在两种序列间无统计学差异(p=0.8),变异系数12-14%。
- 以ADC鉴别肝细胞癌的AUC:常规DWI为0.63(观察者1)、0.62(观察者2);单向DWI为0.65、0.62,AUC间无统计学差异(p=0.6-0.8)。
临床应用与阅片要点
- u-SSEPI可将采集时间缩短至常规DWI的三分之一,且图像质量与病灶检出率无显著差异。
- Bland-Altman图和Passing-Bablok回归分析显示两种序列ADC值间存在系统性和比例性偏倚。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: We evaluated respiratory triggered unidirectional single-shot echo-planar imaging (u-SSEPI) as a time-saving measure in diffusion imaging of the upper abdomen. Specifically, we compared the ADC values obtained from unidirectional DWI (u-SSEPI) and routine DWI (4t-SSEPI) and also the diagnostic accuracies of unidirectional and routine DWI sequences in the identification of focal liver lesions in the setting of chronic liver disease (CLD).
MATERIALS AND METHODS: This prospective, IRB approved study, included 48 patients of CLD who underwent-DCE-MRI on a 1.5 T scanner for hepatocellular carcinoma (HCC) workup. In addition to 4t-SSEPI, u-SSEPI was acquired with the diffusion sensitising gradient being applied in only one direction; keeping all other parameters same as 4t-SSEPI. Two blinded radiologists evaluated the DWI studies for image quality and detection of liver lesions. A composite gold standard was established using DCE-MRI, follow-up imaging and patient clinical details. The apparent diffusion coefficients (ADCs) of the liver, spleen and the lesions were compared between the two sequences. ROC analysis evaluated the diagnostic accuracy of ADC from both the sequences in identifying HCC.
RESULTS: Eighty-eight lesions were identified using the composite gold standard. u-SSEPI resulted in 3 times faster image acquisition. No statistically significant differences were demonstrated between the unidirectional and routine DWI sequences for image quality parameters and lesion detection rates. Lesion wise comparison of the ADC values from both the sequences was not statistically different (p = 0.8) with a coefficient of variation = 12-14 %. The Bland- Altman plots and the Passing-Bablock regression analysis demonstrated a systematic and proportional bias between the ADC values obtained. The AUC of the ROC curve, however, was 0.63-observer1; 0.62-oobserver2 for routine DWI and 0.65; 0.62 for unidirectional DWI when ADC was used to identify HCC (the AUCs were not statistically different (p = 0.6-0.8)).
CONCLUSION: No significant differences were demonstrated in the diagnostic accuracies of unidirectional and routine DWI in the diagnosis of HCC. Unidirectional diffusion may be further evaluated in other organs where diffusion is isotropic, especially in respiratory triggered sequences where the imaging time dividend is significant.
引用
- Ghosh A, Yadav R, Shalimar, et al. Respiratory triggered diffusion-weighted imaging with a single diffusion sensitising gradient to reduce image acquisition time - A feasibility study in the workup of hepatocellular carcinoma. Eur J Radiol. 2021. PMID: 34146912. doi:10.1016/j.ejrad.2021.109807
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。