文献速递腹部技术与安全CT

深度学习图像重建算法用于胰腺方案双能CT:图像质量与碘浓度定量

Deep learning image reconstruction algorithm for pancreatic protocol dual-energy computed tomography: image quality and quantification of iodine concentration.
PubMed 文献 · Eur Radiol · 2021-06-15

这项前瞻性研究纳入30例连续胰腺癌 participant,行胰腺方案双能CT,比较混合迭代重建(40% ASIR-V)与深度学习图像重建中、高水平的图像质量和碘浓度测量。DLIR-M组胰腺癌诊断可接受度和清晰度最佳,DLIR-H组碘浓度标准差最低、变异系数最小,三组碘浓度值基本相当。

要点

  • DLIR-M组胰腺癌诊断可接受度和清晰度显著优于混合迭代重建组和DLIR-H组。
  • DLIR-H组碘浓度标准差显著低于混合迭代重建组和DLIR-M组,变异系数最低。
  • 三组间腹部主动脉、胰腺、胰腺癌、肝脏和门静脉的碘浓度值基本相当。

核心结论

  • DLIR较混合迭代重建可显著提高图像质量并降低碘浓度值的变异性。

研究设计与样本

  • 前瞻性研究,经当地机构审查委员会批准并获书面知情同意,连续纳入30例胰腺癌 participant,行胰腺方案双能CT,数据在70 keV下重建为40%自适应统计迭代重建-Veo(混合迭代重建)、DLIR-M和DLIR-H三组。

关键影像表现/征象

  • 胰腺癌诊断可接受度和清晰度在DLIR-M组显著优于其他组(p < .001-.001)。
  • DLIR-H组碘浓度值的标准差显著更低(p < .001),变异系数最低(p < .001-.002)。
  • 三组间腹部主动脉、胰腺、胰腺癌、肝脏和门静脉的碘浓度值基本相当(p = .001-.9)。

诊断标准与关键数值

  • 采用5分制定性评估胰腺癌的诊断可接受度和清晰度。
  • 计算腹部主动脉、胰腺、胰腺癌、肝脏和门静脉的碘浓度值、标准差和变异系数。

临床应用与阅片要点

  • DLIR-M在胰腺癌诊断可接受度和清晰度上表现最佳,可能有助于胰腺方案双能CT的病灶显示。
  • DLIR-H可降低碘浓度值的标准差和变异系数,可能提升碘浓度定量的稳定性。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the image quality and iodine concentration (IC) measurements in pancreatic protocol dual-energy computed tomography (DECT) reconstructed using deep learning image reconstruction (DLIR) and compare them with those of images reconstructed using hybrid iterative reconstruction (IR).

METHODS: The local institutional review board approved this prospective study. Written informed consent was obtained from all participants. Thirty consecutive participants with pancreatic cancer (PC) underwent pancreatic protocol DECT for initial evaluation. DECT data were reconstructed at 70 keV using 40% adaptive statistical iterative reconstruction-Veo (hybrid-IR) and DLIR at medium and high levels (DLIR-M and DLIR-H, respectively). The diagnostic acceptability and conspicuity of PC were qualitatively assessed using a 5-point scale. IC values of the abdominal aorta, pancreas, PC, liver, and portal vein; standard deviation (SD); and coefficient of variation (CV) were calculated. Qualitative and quantitative parameters were compared between the hybrid-IR, DLIR-M, and DLIR-H groups.

RESULTS: The diagnostic acceptability and conspicuity of PC were significantly better in the DLIR-M group compared with those in the other groups (p < .001-.001). The IC values of the anatomical structures were almost comparable between the three groups (p = .001-.9). The SD of IC values was significantly lower in the DLIR-H group (p < .001) and resulted in the lowest CV (p < .001-.002) compared with those in the hybrid-IR and DLIR-M groups.

CONCLUSIONS: DLIR could significantly improve image quality and reduce the variability of IC values than could hybrid-IR.

KEY POINTS: Image quality and conspicuity of pancreatic cancer were the best in DLIR-M. DLIR significantly reduced background noise and improved SNR and CNR. The variability of iodine concentration was reduced in DLIR.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Noda Y, Kawai N, Nagata S, et al. Deep learning image reconstruction algorithm for pancreatic protocol dual-energy computed tomography: image quality and quantification of iodine concentration. Eur Radiol. 2021. PMID: 34131785. doi:10.1007/s00330-021-08121-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。