文献速递腹部技术与安全US

双重超声造影明确胃癌肿瘤深度(T分期)的诊断准确性:Meta分析

Diagnostic Accuracy of Double Contrast-Enhanced Ultrasonography in Clarifying Tumor Depth (T Stage) of Gastric Cancer: Meta-analysis.
PubMed 文献 · Ultrasound Med Biol · 2021-06-23

本Meta分析纳入6项研究共926例胃癌患者,评估双重超声造影(DCEUS)判断T分期的诊断准确性。DCEUS鉴别T1-T2与T3-T4的汇总敏感度和特异度分别为0.94和0.91;各期敏感度/特异度为T1 0.67/0.98、T2 0.81/0.95、T3 0.89/0.86、T4 0.87/0.96。作者认为DCEUS鉴别T1-T2的准确性高于T3-T4,T3期的诊断价值需进一步考虑。

要点

  • DCEUS鉴别T1-T2与T3-T4胃癌的汇总敏感度0.94、特异度0.91。
  • T1期敏感度仅0.67但特异度0.98,T2期敏感度0.81、特异度0.95。
  • T3期敏感度0.89、特异度0.86,诊断价值需进一步考虑。

核心结论

  • DCEUS鉴别T1-T2期胃癌的准确性高于鉴别T3-T4期,T3期的诊断价值需进一步考虑;DCEUS的诊断准确性可用于指导外科医生对胃癌患者进行更精准的术前诊断。

研究设计与样本

  • Meta分析,检索Cochrane Library CENTRAL、OVID MEDLINE、EMBASE、PUBMED和EBSCOhost至2019年,纳入6项研究共926例经DCEUS诊断的胃癌患者,所有患者均接受DCEUS检查,纳入研究质量良好。

诊断标准与关键数值

  • DCEUS鉴别T1-T2与T3-T4胃癌的汇总敏感度0.94、特异度0.91;T1期敏感度0.67、特异度0.98,T2期敏感度0.81、特异度0.95,T3期敏感度0.89、特异度0.86,T4期敏感度0.87、特异度0.96;SROC曲线AUC:T1-T2为0.97,T1为0.82、T2为0.84、T3为0.91、T4为0.97。

临床应用与阅片要点

  • 作者认为DCEUS的诊断准确性可用于指导外科医生对胃癌患者进行更精准的术前诊断。

局限性

  • 原文指出DCEUS鉴别T3期的诊断价值需进一步考虑。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

This study aimed to quantitatively analyze published data regarding the ability of double contrast-enhanced ultrasonography (DCEUS) to clarify tumor depth (T stage) in primary gastric carcinoma patients. We obtained six studies, including 926 gastric cancer (GC) patients who were diagnosed by DCEUS from the Cochrane Library "Cochrane Central Register of Controlled Trials (CENTRAL)," OVID MEDLINE, EMBASE, PUBMED and EBSCOhost, to 2019. Sensitivity (SEN), specificity (SPE), positive likelihood ratio (PLR), negative likelihood ratio (NLR), forest plot analysis and summary receiver operating characteristic (SROC) curve analysis were used to evaluate the diagnostic accuracy of DCEUS. In our study, all the patients were examined by DCEUS. The quality of all included studies was good. The meta-analysis of six studies (n = 926) revealed that the summary sensitivity and specificity of DCEUS in discriminating T1-T2 versus T3-T4 gastric carcinomas were 0.94 and 0.91, respectively. The pooled sensitivity and specificity of DCEUS were 0.67 and 0.98 for T1 stage, 0.81 and 0.95 for T2 stage, 0.89 and 0.86 for T3 stage and 0.87 and 0.96 for T4 stage, respectively. The SROC curve revealed that the areas under the curve (AUC) of T1-T2 were 0.97 for each stage and 0.82 (T1), 0.84 (T2), 0.91 (T3) and 0.97 (T4). These results indicate that the accuracy of DCEUS in discriminating T1-T2 is higher than that in discriminating T3-T4, and the diagnostic value of DCEUS in discriminating the T3 stage requires further consideration. Finally, our analysis suggested that the diagnostic accuracy of DCEUS is available to guide surgeons in the pre-operative diagnosis of GC patients for more precise treatment.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Xu L, Wang X, Wu W, et al. Diagnostic Accuracy of Double Contrast-Enhanced Ultrasonography in Clarifying Tumor Depth (T Stage) of Gastric Cancer: Meta-analysis. Ultrasound Med Biol. 2021. PMID: 34172338. doi:10.1016/j.ultrasmedbio.2021.05.017

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。