虚拟平扫图像:不同双能CT扫描仪在患者与体模研究中的定性与定量比较
回顾性纳入44例在3种双能CT扫描仪上接受腹部增强检查的患者及相同方案扫描的体模,比较虚拟平扫图像的衰减、噪声及主观质量。结果显示各扫描仪间虚拟平扫衰减与噪声存在显著差异,dlDECT与rsDECT在主动脉、门静脉和肾脏的虚拟平扫衰减显著高于dsDECT,而dsDECT在皮下和腹膜后脂肪的衰减显著更高;定性上dsDECT碘消除最佳,dlDECT与rsDECT在锐利度、噪声和整体图像质量上评分更高。作者结论认为使用不同双能CT扫描仪随访时应认识到这些扫描仪间差异。
要点
- 不同双能CT扫描仪间虚拟平扫图像的衰减测量与定性评估存在显著差异。
- dlDECT与rsDECT在主动脉、门静脉和肾脏的虚拟平扫衰减显著高于dsDECT(P < 0.05)。
- dsDECT在皮下和腹膜后脂肪的虚拟平扫衰减显著高于dlDECT/rsDECT(均P < 0.05)。
核心结论
- 虚拟平扫图像在衰减测量和定性评估上存在显著扫描仪间差异。
- 在患者于不同双能CT扫描仪类型间进行影像随访时使用这些图像,应认识到上述差异。
研究设计与样本
- 回顾性研究,纳入44例在3种双能CT扫描仪类型上均接受临床腹部增强检查的患者,以及以相同方案扫描的体模。
- 对虚拟平扫图像进行定性与定量评估,定量包括多种组织和体模的衰减与图像噪声测量。
- 计算患者内扫描仪间虚拟平扫衰减可重复性,定义为扫描仪间差异≤10 HU的测量对百分比。
- 由2名放射科医师对图像质量、噪声、锐利度和碘消除进行定性评估。
关键影像表现/征象
- 所有组织中均发现虚拟平扫衰减和噪声存在显著扫描仪间差异。
- dlDECT与rsDECT在主动脉、门静脉和肾脏的虚拟平扫衰减显著高于dsDECT(P < 0.05)。
- dsDECT在皮下和腹膜后脂肪的虚拟平扫衰减显著高于dlDECT/rsDECT(均P < 0.05)。
- 定性评估中dsDECT碘消除最佳,而dlDECT与rsDECT在锐利度、图像噪声和整体图像质量上评分更高。
诊断标准与关键数值
- 扫描仪间虚拟平扫衰减可重复性:rsDECT与dlDECT之间为91.9%(385/419)的测量对差异≤10 HU。
- dsDECT与rsDECT之间可重复性为70.9%(297/419),dsDECT与dlDECT之间为66.8%(280/419)。
- 含对比剂体模腔的虚拟平扫衰减:dlDECT为12.7 ± 4.7 HU,rsDECT为-5.3 ± 4.2 HU,dsDECT为-4.0 ± 10.7 HU,dlDECT与rsDECT/dsDECT之间差异显著(P < 0.05)。
- 无对比剂的体模腔外组件中,各扫描仪间衰减可比(P = 0.11-0.62)。
临床应用与阅片要点
- 使用虚拟平扫图像进行随访时,应认识到不同双能CT扫描仪类型间的衰减和图像质量差异。
- dlDECT与rsDECT的虚拟平扫衰减在主动脉、门静脉和肾脏高于dsDECT,而在皮下和腹膜后脂肪低于dsDECT。
- dsDECT碘消除最佳,dlDECT与rsDECT在锐利度、噪声和整体图像质量上评分更高。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
MATERIALS AND METHODS: Forty-four patients with clinical contrast-enhanced abdominal examinations on each of the 3 DECT scanner types and a phantom scanned with the same protocols were included in this retrospective study. Qualitative and quantitative assessment was performed on VUE images. Quantitative evaluation included measurement of attenuation and image noise for various tissues and the phantom. Virtual unenhanced image attenuation and noise were compared between scanner types, and intrapatient interscanner reproducibility of virtual unenhanced image attenuation was calculated as the percentage of measurement pairs with an interscanner difference ≤ 10 HU. Image quality, noise, sharpness, and iodine elimination were assessed qualitatively by 2 radiologists.
RESULTS: Significant interscanner differences in VUE attenuation and noise were found in all tissues. dlDECT and rsDECT showed significantly higher VUE attenuation than dsDECT in the aorta, portal vein, and kidneys (P < 0.05). Conversely, VUE attenuation in dsDECT was significantly higher than in dlDECT/rsDECT for subcutaneous and retroperitoneal fat (both P < 0.05). A total of 91.9% (385/419) of measurements were reproducible between rsDECT and dlDECT, 70.9% (297/419) between dsDECT and rsDECT, and 66.8% (280/419) between dsDECT and dlDECT. Virtual unenhanced image attenuation in the contrast media-filled phantom cavity was 12.7 ± 4.7 HU in dlDECT, -5.3 ± 4.2 HU in rsDECT, and -4.0 ± 10.7 HU in dsDECT with significant differences between dlDECT and rsDECT/dsDECT, respectively (P < 0.05), between which attenuation was comparable in the unenhanced extraluminal phantom component (P = 0.11-0.62). Qualitatively, dsDECT yielded best iodine elimination, whereas sharpness, image noise, and overall image quality were rated higher in dlDECT and rsDECT.
CONCLUSIONS: There are significant interscanner differences in the attenuation measurements and qualitative assessment of VUE images, which should be acknowledged when using these images in patients that are being scanned on different DECT scanner types during imaging follow-up.
引用
- Lennartz S, Pisuchpen N, Parakh A, et al. Virtual Unenhanced Images: Qualitative and Quantitative Comparison Between Different Dual-Energy CT Scanners in a Patient and Phantom Study. Invest Radiol. 2022. PMID: 34162795. doi:10.1097/RLI.0000000000000802
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。