腹部横断面介入放射学中使用的针具类型:腹部放射学会新兴技术委员会的调查
该调查向腹部放射学会(SAR)新兴技术委员会中从事横断面介入放射学(CSIR)的成员发放13题问卷,了解其在实性器官活检、超声引导下腹腔穿刺和超声引导下甲状腺细针穿刺(FNA)中常用的针具类型,共回收19份问卷(应答率57.6%,19/33),来自16家机构。结果显示实性器官活检最常用18G自动击发、可变射程针,腹腔穿刺最常用5F Cook Yueh针,甲状腺FNA全部使用脊髓针且以25G最常见(72.2%,13/18)。
要点
- 实性器官活检最常用18G自动击发、可变射程针,随机与靶向活检中Argon BioPince均占26.3%(5/19)。
- 超声引导下腹腔穿刺最常用5F Cook Yueh针,占36.8%(7/19)。
- 甲状腺FNA全部受访者使用脊髓针,25G最常见,占72.2%(13/18)。
核心结论
- 腹部放射科医生在常见介入操作中使用多种针具;SAR CSIR ETC成员实性器官活检常用18G自动可变射程针,腹腔穿刺常用5F导管样式针,甲状腺FNA常用25G脊髓针。
研究设计与样本
- 向SAR新兴技术委员会中CSIR成员发放13题问卷,调查实性器官随机与靶向活检、超声引导下腹腔穿刺、超声引导下甲状腺FNA所用针具;共回收19份问卷(应答率57.6%,19/33),来自16家机构,结果用描述性统计汇总并复习最常用针具的特征。
诊断标准与关键数值
- 实性器官活检:多数受访者使用18G自动击发、可变射程针;随机与靶向活检最常用均为Argon BioPince(26.3%,5/19);最常用三种针均具备自动击发、可变射程和18G规格。
- 超声引导下腹腔穿刺:最常用5F Cook Yueh针(36.8%,7/19)。
- 超声引导下甲状腺FNA:全部受访者使用脊髓针,25G最常见(72.2%,13/18)。
临床应用与阅片要点
- 调查显示SAR CSIR ETC成员在实性器官活检中常用18G自动击发、可变射程针,随机与靶向活检最常用为Argon BioPince(26.3%,5/19)。
- 调查显示SAR CSIR ETC成员在超声引导下腹腔穿刺中常用5F Cook Yueh针(36.8%,7/19)。
- 调查显示SAR CSIR ETC成员在超声引导下甲状腺FNA中全部使用脊髓针,25G最常见(72.2%,13/18)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To identify commonly used needle types in cross-sectional interventional radiology (CSIR) and to review features and safety profiles of those needles.
METHODS: Members of the Society of Abdominal Radiology (SAR) emerging technologies commission (ETC) on CSIR were sent a 13-question survey about what needles they use for common CSIR procedures: random and targeted solid organ biopsy, ultrasound-guided paracentesis, and ultrasound-guided thyroid fine needle aspiration (FNA). Results were compiled with descriptive statistics, and features of the most commonly used needles were reviewed.
RESULTS: 19 surveys were completed (response rate 57.6%, 19/33) from 16 institutions. For solid organ biopsies, the majority of respondents reported using an 18-gauge needle with an automatic firing mechanism and a variable throw length option. The most commonly used needle for both random and targeted biopsies was the Argon BioPince (26.3%, 5/19) The three most commonly used needles for solid organ biopsies all featured automatic firing, variable throw length options, and 18-gauge size. A 5 French Cook Yueh needle was most the most commonly used paracentesis needle (36.8%, 7/19). For thyroid FNA, all respondents used spinal needles, and 25-gauge was the most common size (72.2%, 13/18).
CONCLUSION: Abdominal radiologists use a variety of needles when performing common interventional procedures. Members of the SAR CSIR ETC commonly use automatic, 18-gauge, variable throw length needles for solid organ biopsies, 5 French catheter style needles for paracentesis, and 25-gauge spinal needles for thyroid FNA.
引用
- Wildman-Tobriner B, Ho LM, Bowman AW, et al. Needle types used in abdominal cross-sectional interventional radiology: a survey of the Society of Abdominal Radiology emerging technology commission. Abdom Radiol (NY). 2021. PMID: 34128102. doi:10.1007/s00261-021-03145-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。