文献速递腹部技术与安全US

对比增强超声肝脏影像报告和数据系统的阅片者间信度:一项Meta分析

Inter-reader reliability of contrast-enhanced ultrasound Liver Imaging Reporting and Data System: a meta-analysis.
PubMed 文献 · Abdom Radiol (NY) · 2021-06-22

该Meta分析检索2016年1月至2021年3月数据库,纳入12项研究共2862个病灶,评估对比增强超声LI-RADS的阅片者间信度。主要特征和LI-RADS分类的合并κ值分别为0.73、0.69和0.75,LR-M特征κ值较低(0.54、0.62)。作者认为影像特征定义需进一步完善以提高信度。

要点

  • 非环状动脉期高增强的合并κ为0.73,提示阅片者间信度中等至良好。
  • LR-M特征(环状动脉期高增强κ=0.54,早期廓清κ=0.62)信度低于主要特征。
  • LI-RADS分类的合并κ为0.75,但存在显著研究异质性,病灶大小和阅片者经验同质性与异质性相关(p=0.03)。

核心结论

  • CEUS LI-RADS对主要特征和LI-RADS分类显示中等至良好的阅片者间信度,但LR-M特征的信度相对较低;作者认为影像特征定义需进一步完善以提高CEUS LI-RADS的阅片者间信度。

研究设计与样本

  • Meta分析,检索MEDLINE、EMBASE和Cochrane数据库(2016年1月至2021年3月),纳入12项报告CEUS LI-RADS阅片者间信度的原始研究,共2862个病灶,采用DerSimonian-Laird随机效应模型计算合并κ值,并进行Meta回归分析探索异质性原因。

诊断标准与关键数值

  • 非环状动脉期高增强的合并κ为0.73(95%CI 0.67-0.79)。
  • 轻度及晚期廓清的合并κ为0.69(95%CI 0.54-0.84)。
  • 环状动脉期高增强的合并κ为0.54(95%CI 0.37-0.71)。
  • 早期廓清的合并κ为0.62(95%CI 0.45-0.79)。
  • LI-RADS分类的合并κ为0.75(95%CI 0.64-0.87)。

临床应用与阅片要点

  • 作者认为,影像特征的定义需要进一步完善,以提高CEUS LI-RADS的阅片者间信度。

局限性

  • LI-RADS分类存在显著的研究异质性,病灶大小(p=0.03)和阅片者经验同质性(p=0.03)与研究异质性显著相关。
  • 作者认为影像特征定义需进一步完善以提高阅片者间信度。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To systematically determine the inter-reader reliability of the contrast-enhanced ultrasound (CEUS) Liver Imaging Reporting and Data System (LI-RADS), with emphasis on its major features for hepatocellular carcinoma (HCC) and LR-M (LI-RADS category M) features for non-HCC malignancy.

METHODS: MEDLINE, EMBASE, and Cochrane databases were searched from January 2016 to March 2021 to identify original articles reporting the inter-reader reliability of CEUS LI-RADS. Meta-analytic pooled kappa values (κ) were calculated for major features [nonrim arterial-phase hyperenhancement (APHE), mild and late washout], LR-M features (rim APHE, early washout), and LI-RADS categorization using the DerSimonian-Laird random-effects model. Meta-regression analysis was performed to explore any causes of study heterogeneity.

RESULTS: Twelve studies with a total of 2862 lesions were included. The meta-analytic pooled κ of nonrim APHE, mild and late washout, rim APHE, early washout, and LI-RADS categorization were 0.73 [95% confidence interval (CI), 0.67 - 0.79], 0.69 (95% CI, 0.54-0.84), 0.54 (95% CI, 0.37-0.71), 0.62 (95% CI, 0.45-0.79), and 0.75 (95% CI, 0.64-0.87), respectively. Compared with the major features, LR-M features had a lower meta-analytic pooled κ. Substantial study heterogeneity was noted in the LI-RADS categorization, and lesion size (p = 0.03) and the homogeneity in reader experience (p = 0.03) were significantly associated with study heterogeneity.

CONCLUSIONS: CEUS LI-RADS showed substantial inter-reader reliability for major features and LI-RADS categorization, but relatively lower reliability was found for LR-M features. In our opinion, the definitions of imaging features require further refinement to improve the inter-reader reliability of CEUS LI-RADS.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Kang JH, Choi SH, Lee JS, et al. Inter-reader reliability of contrast-enhanced ultrasound Liver Imaging Reporting and Data System: a meta-analysis. Abdom Radiol (NY). 2021. PMID: 34156509. doi:10.1007/s00261-021-03169-7

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。