一种产前超声扫查方法:中晚孕期的一键式技术

A Prenatal Ultrasound Scanning Approach: One-Touch Technique in Second and Third Trimesters.
PubMed 文献 · Ultrasound Med Biol · 2021-05-28

前瞻性研究纳入1005例无并发症单胎妊娠,比较新型Smart Fetus(SF)技术与传统超声技术(TUT)获取标准切面及生物学测量的表现。SF在998/1005例(99.30%)中成功完成切面获取和全部测量,两种技术测量一致性高,SF获取切面及测量所需时间显著短于TUT,两名独立观察者重复测量无显著差异。SF有助于获取可靠标准切面与生物学测量并节省时间,可能作为新的超声扫查方法改善工作流程效率。

要点

  • SF在99.30%(998/1005)的无并发症单胎妊娠中成功获取标准切面并完成全部生物学测量。
  • SF与TUT在所有测量上一致性高,且SF获取切面及测量时间显著短于TUT。
  • 两名独立观察者使用SF重复测量无显著差异,提示重复性良好。

核心结论

  • SF技术有助于获取可靠的标准切面和生物学测量并节省时间,可能作为一种新的超声扫查方法并改善工作流程效率。

研究设计与样本

  • 前瞻性研究纳入1005例无并发症单胎妊娠,于中晚孕期常规检查时获取丘脑横切面、腹部横切面和股骨纵切面,并使用SF与TUT获取双顶径、头围、腹围和股骨长度,比较准确性、重复性和分析所需时间。

关键影像表现/征象

  • SF获取的切面包括丘脑横切面、腹部横切面和股骨纵切面。
  • SF测量的生物学参数包括双顶径、头围、腹围和股骨长度。

诊断标准与关键数值

  • SF在998/1005例(99.30%)中成功获取切面并完成所有测量。
  • SF与TUT在所有测量上一致性高。
  • SF获取切面并测量生物学参数或仅测量生物学参数的时间均显著短于TUT。
  • 两名独立观察者使用SF重复测量无显著差异。

临床应用与阅片要点

  • 作者认为SF技术有助于获取可靠标准切面与生物学测量并节省时间,可能作为新的超声扫查方法并改善工作流程效率。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

This study was aimed at evaluating the performance of the innovative technique Smart Fetus (SF) developed to recognize the planes and obtain the basic biometric measurements of fetuses automatically. This prospective study included 1005 uncomplicated singleton pregnancies undergoing routine examinations. For every pregnancy, planes, including the transverse section of the thalami, transverse section of the abdomen and longitudinal section of the femur, were acquired, and standard biometric measurements, including biparietal diameter, head circumference, abdominal circumference and femur length, were obtained using SF and traditional ultrasound technique (TUT). The accuracy, reproducibility and time required for the analysis of SF were compared with those of TUT. In 998 of 1005 cases (99.30%), SF successfully acquired the sections and made all measurements. The agreement between the techniques was high for all measurements. The time to obtain sections and measure biometric parameters or solely measure biometric parameters was significantly shorter with SF than with TUT. No significant differences were found in SF repeated measurements obtained by two independent observers. The SF technique helped in the acquisition of reliable standard sections and biometric measurements and saved time. It might serve as a novel ultrasound scanning approach and improve workflow efficiency.