文献速递儿科影像腹部技术与安全US

肝脏剪切波弹性成像与衰减成像系数测量:健康儿童的前瞻性评估

Liver shear wave elastography and attenuation imaging coefficient measures: prospective evaluation in healthy children.
PubMed 文献 · Abdom Radiol (NY) · 2021-06-08

前瞻性单中心研究纳入86名无肝病病史的儿童,使用Aplio i800超声系统测量肝脏剪切波弹性成像(SWE)与衰减成像(ATI)系数。SWE中位值4.6 kPa [3.3-6.6],ATI中位值0.65 [0.5-0.81] dB/cm/MHz,年龄、性别、体重及BMI均无影响。作者认为这些正常值可能有助于更好地表征儿童肝实质。

要点

  • 健康儿童肝脏SWE中位值4.6 kPa [3.3-6.6],可用于儿童肝硬度评估的参考。
  • ATI系数中位值0.65 [0.5-0.81] dB/cm/MHz,77例获得有效测量。
  • 年龄、性别、体重及BMI对SWE和ATI测量值均无显著影响。

核心结论

  • 研究提供了健康儿童的肝脏SWE和ATI正常值,这些定量数据可能有助于更好地表征儿童肝实质。

研究设计与样本

  • 前瞻性单中心研究,2019年1月至2020年6月在一所大学医院招募86名儿童(45名男孩、41名女孩),均有临床指征行超声检查且无已知或记录的肝病病史;使用Aplio i800(Canon Medical Systems)超声系统与i8CX1探头;SWE采用显示自动测量区域网格叠加的彩色图获取,ATI系数由右肝每个感兴趣区自动生成。

诊断标准与关键数值

  • 肝脏SWE中位值4.6 kPa [3.3-6.6],全部儿童均获得SWE测量。
  • ATI系数中位值0.65 [0.5-0.81] dB/cm/MHz,77例获得有效测量。
  • 年龄、性别、体重及体质指数对SWE和ATI测量值均无影响。

临床应用与阅片要点

  • 作者认为所提供的SWE和ATI正常值可能有助于更好地表征儿童肝实质。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Ultrasonographic quantitative measurements enable characterizing the stiffness and viscosity of liver parenchyma. Normal Shear Wave Elastography (SWE) values have been reported in adults and children. The Attenuation Imaging (ATI) coefficient is a measure of local sound energy loss thought to reflect steatosis in adults. The aim of our study was to provide normal SWE and ATI liver values in healthy children.

METHODS: A prospective monocentric study was conducted recruiting 86 children (45 boys and 41 girls) from a single University Hospital between January 2019 and June 2020, having a clinically indicated ultrasound examination, without a known or documented history of liver disease. Examinations were performed using an Aplio i800 (Canon Medical Systems) ultrasound system with an i8CX1 transducer. SWE measurements were obtained using a color map showing an automated measurement area grid overlay. ATI coefficients were generated automatically for each region of interest in the right liver.

RESULTS: Overall median age for the pediatric population was 106 months (1-180 months; SD 49 months). Children were normal weighted. Liver SWE was available for all children. The median liver SWE was 4.6 kPa [3.3-6.6]. ATI yielded valid measurements in 77 patients. The median ATI coefficient was 0.65 [0.5-0.81] dB/cm/MHz. No impact of age, sex, weight and Body Mass Index was observed.

CONCLUSION: SWE and ATI liver values were provided in healthy children. The normative quantitative data might be useful to characterize liver parenchyma in children better.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Cailloce R, Tavernier E, Brunereau L, et al. Liver shear wave elastography and attenuation imaging coefficient measures: prospective evaluation in healthy children. Abdom Radiol (NY). 2021. PMID: 34100966. doi:10.1007/s00261-021-02960-w

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。