文献速递腹部CT

低容量减量肠道准备方案用于CT结肠成像:一项随机非劣效性试验

Low-volume reduced bowel preparation regimen for CT colonography: a randomized noninferiority trial.
PubMed 文献 · Abdom Radiol (NY) · 2021-06-18

这项随机非劣效性试验将110名转诊行CT结肠成像的连续参与者随机分配至低容量减量肠道准备组(52.5 g PMF104溶于500 mL水)或全容量减量肠道准备组(105 g PMF104溶于1000 mL水),由五名盲法读者独立评分肠道准备质量。结果显示两组结肠清洁质量评分0分的结肠段比例非劣效,低容量组准备期间排便次数更少,胃肠道耐受性更好。

要点

  • 低容量减量肠道准备在结肠清洁质量上非劣效于全容量方案,非劣效界值为10%。
  • 俯卧位清洁评分0分比例低容量组92% vs 全容量组94%,仰卧位94% vs 92%。
  • 低容量组准备期间排便次数更少(7±5次 vs 10±6次,p=0.002),耐受性更优。

核心结论

  • 低容量减量肠道准备用于CT结肠成像的结肠清洁质量非劣效于全容量减量方案,且胃肠道耐受性更优。

研究设计与样本

  • 随机非劣效性试验,纳入110名转诊行CT结肠成像的连续参与者,随机分为低容量减量肠道准备组(n=55)和全容量减量肠道准备组(n=55)。低容量方案为52.5 g PMF104溶于500 mL水,全容量方案为105 g PMF104溶于1000 mL水。图像由五名盲法读者独立评分,肠道准备质量评分0分(最佳)至3分(最差)。主要结局为清洁质量评分为0分的结肠段比例的非劣效性,非劣效界值为10%。

诊断标准与关键数值

  • 肠道准备质量评分0分(最佳)至3分(最差);主要结局为非劣效性检验,非劣效界值为10%。俯卧位清洁评分0分比例:低容量组92% vs 全容量组94%,风险差-2.1(95%CI -5.9至1.7)。仰卧位清洁评分0分比例:低容量组94% vs 全容量组92%,风险差1.5(95%CI -2.4至5.4)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To determine whether the quality of a low-volume reduced bowel preparation (LV-RBP) for CT Colonography (CTC) is noninferior to full-volume reduced bowel preparation (FV-RBP) regimen.

METHODS: In this randomized controlled trial, consecutive participants referred for CTC were randomly assigned to receive LV-RBP (52.5 g of PMF104 in 500 mL of water) or FV-RBP (105 g of PMF104 in 1000 mL of water). Images were independently reviewed by five blinded readers who rated the quality of bowel preparation from 0 (best score) to 3 (worst score). The primary outcome was the noninferiority of LV-RBP to FV-RBP in the proportion of colonic segments scored 0 for cleansing quality, with noninferiority margin of 10%. Volume of residual fluids, colonic distension, lesions and polyps detection rates and patient tolerability were secondary outcomes.

RESULTS: From March 2019 to January 2020, 110 participants (mean age 65 years ± 14 [standard deviation]; 74 women) were allocated to LV-RBP (n = 55) or FV-RBP (n = 55) arms. There were 92% segment scored 0 in colon cleansing quality in LV-RBP and 94% in FV-RBP for prone scans, and 94% vs 92% for supine scans. Risk difference was - 2.1 (95% CI -5.9 to 1.7) and 1.5 (95% CI -2.4 to 5.4) for prone and supine positions, respectively. Residual fluids and colonic distension were also noninferior in LV-RBP. LV-RBP was associated with a lower number of evacuations during preparation (7 ± 5 vs 10 ± 6, p = 0.002).

CONCLUSION: The LV-RBP for CTC demonstrated noninferior quality of colon cleansing with improved gastrointestinal tolerability compared to FV-RBP regimen.

来源:Abdom Radiol (NY),查看原文。版权归原作者所有。

引用

  1. Bellini D, Panvini N, Vicini S, et al. Low-volume reduced bowel preparation regimen for CT colonography: a randomized noninferiority trial. Abdom Radiol (NY). 2021. PMID: 34143258. doi:10.1007/s00261-021-03176-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。