文献速递腹部MR

基于Gd-EOB-DTPA增强肝脏MRI的影像组学分析用于评估功能性肝脏储备

Radiomics Analysis of Gd-EOB-DTPA Enhanced Hepatic MRI for Assessment of Functional Liver Reserve.
PubMed 文献 · Acad Radiol · 2021-06-25

本研究从60例肝细胞癌患者的Gd-EOB-DTPA增强MRI图像中提取影像组学特征,用Boruta算法筛选与吲哚菁绿15分钟滞留率(ICG R15)相关的特征,并构建随机森林回归预测与分类模型;预测值与实际ICG R15显著相关(R=0.90,P<0.001),分类模型识别ICG R15<10%、<15%、<20%的AUC分别为0.906、0.954、0.996。

要点

  • 基于Gd-EOB-DTPA增强MRI的影像组学预测值与实际ICG R15显著相关(R=0.90,P<0.001)。
  • 分类模型识别ICG R15<10%、<15%、<20%的AUC分别为0.906、0.954、0.996。
  • 共提取165个影像组学特征,预测模型选用6个特征,分类模型选用9个特征。

核心结论

  • 基于Gd-EOB-DTPA增强肝脏MRI的影像组学分析可用于评估肝细胞癌患者的功能性肝脏储备。

研究设计与样本

  • 研究纳入60例肝细胞癌患者,从Gd-EOB-DTPA增强MRI图像中提取影像组学特征,以吲哚菁绿15分钟滞留率(ICG R15)为参考标准。

诊断标准与关键数值

  • 预测模型经Pearson相关分析显示预测值与实际ICG R15显著相关(R=0.90,P<0.001)。
  • 分类模型识别ICG R15<10%的AUC为0.906(95%CI:0.900-0.913)。
  • 分类模型识别ICG R15<15%的AUC为0.954(95%CI:0.950-0.958)。
  • 分类模型识别ICG R15<20%的AUC为0.996(95%CI:0.995-0.996)。
  • 共提取165个影像组学特征,预测模型选用6个特征,分类模型选用9个特征。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Rationale and Objectives To evaluate the effectiveness of radiomics analysis based on Gd-EOB-DTPA enhanced hepatic MRI for functional liver reserve assessment in HCC patients. Materials and Methods Radiomics features were extracted from Gd-EOB-DTPA enhanced MRI images in 60 HCC patients. Boruta algorithm was performed to select features associated with indocyanine green retention rate at 15 min (ICG R15). Prediction and classification model were built by performing Random Forest regression analysis. Pearson correlation analysis and AUC of ROC were used to assess performance of the two models. Results A total of 165 radiomics features were extracted. Six radiomics features were selected to build the prediction model. A Predicted value of ICG R15 for each patient was calculated by the prediction model. Pearson correlation analysis revealed that predicted values were significantly associated with actual values of ICG R15 (R value = 0.90, p < 0.001). Nine radiomics features were selected to build the classification model. AUC of ROC revealed favorable performance of the classification model for identifying patients with ICG R15 <10% (AUC: 0.906, 95%CI: 0.900-0.913), <15% (AUC: 0.954, 95%CI: 0.950-0.958), and <20% (AUC: 0.996, 95%CI: 0.995-0.996). Conclusion Radiomics analysis of Gd-EOB-DTPA enhanced hepatic MRI can be used for assessment of functional liver reserve in HCC patients.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Shi Z, Cai W, Feng X, et al. Radiomics Analysis of Gd-EOB-DTPA Enhanced Hepatic MRI for Assessment of Functional Liver Reserve. Acad Radiol. 2021. PMID: 34183230. doi:10.1016/j.acra.2021.04.019

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。