无磁化标记动态成像测量心搏诱导肝脏变形作为肝硬度指标:临床前概念验证、临床转化、可重复性及在肝硬化患者中的可行性
本研究评估非刚性配准动态二维电影MRI测量心搏诱导肝脏变形(LD)作为肝硬度指标的价值。在胆管结扎大鼠中,归一化LD显著高于假手术组;健康志愿者7天可重复性和观察者间变异良好;餐后LD变化无统计学意义;肝硬化患者LD与健康志愿者无显著差异。
要点
- 心搏诱导肝脏变形(LD)在胆管结扎大鼠中显著高于假手术组,支持其作为肝硬度指标的概念。
- 健康志愿者7天可重复性Bland-Altman一致性界限为±0.028 a.u.,观察者间变异一致性界限为±0.030 a.u.。
- 肝硬化患者LD与健康志愿者无显著差异(0.102±0.0099 a.u. vs 0.080±0.0063 a.u.,P=0.0847)。
核心结论
- 心搏诱导LD在临床前研究中概念合理,测量可重复性和观察者间变异良好,较少受肝脏血流动力学变化影响,且在肝硬化患者中可行。
研究设计与样本
- 临床前动物实验(21只胆管结扎大鼠、17只假手术对照)及临床可行性研究(11例肝硬化患者、10例健康志愿者),采用 spoiled gradient-echo 短轴心脏电影MRI,大鼠9.4 T、人类3.0 T,参考标准未明确报告。
关键影像表现/征象
- LD测量取自靠近膈肌边缘的肝内膈下感兴趣区。
- 胆管结扎大鼠归一化LD为1.304±0.062,假手术组为1.058±0.045(P=0.0031)。
- 健康志愿者餐后LD增加无统计学意义(+0.0083±0.0076 a.u.,P=0.3028),与门静脉血流变化无相关性(r=0.42,P=0.2219)。
- 肝硬化患者LD为0.102±0.0099 a.u.,健康志愿者为0.080±0.0063 a.u.(P=0.0847),差异未达统计学显著。
诊断标准与关键数值
- 归一化LD在胆管结扎大鼠为1.304±0.062,假手术组为1.058±0.045(P=0.0031)。
- 健康志愿者7天可重复性Bland-Altman一致性界限为±0.028 a.u.,观察者间变异一致性界限为±0.030 a.u.。
- 餐后LD变化+0.0083±0.0076 a.u.(P=0.3028),与门静脉血流变化相关系数r=0.42(P=0.2219)。
- 肝硬化患者LD 0.102±0.0099 a.u. vs 健康志愿者0.080±0.0063 a.u.(P=0.0847)。
临床应用与阅片要点
- LD测量可取自靠近膈肌边缘的肝内膈下感兴趣区,所有患者均成功获得测量。
- 健康志愿者餐后LD变化无统计学意义,提示测量可能较少受餐后血流动力学变化影响。
局限性
- 肝硬化患者与健康志愿者LD差异未达统计学显著(P=0.0847)。
- 原文未报告其他局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: MR elastography and magnetization-tagging use liver stiffness (LS) measurements to diagnose fibrosis but require physical drivers, specialist sequences and post-processing. Here we evaluate non-rigid registration of dynamic two-dimensional cine MRI images to measure cardiac-induced liver deformation (LD) as a measure of LS by (i) assessing preclinical proof-of-concept, (ii) clinical reproducibility and inter-reader variability, (iii) the effects of hepatic hemodynamic changes and (iv) feasibility in patients with cirrhosis.
METHODS: Sprague-Dawley rats (n = 21 bile duct ligated (BDL), n = 17 sham-operated controls) and fasted patients with liver cirrhosis (n = 11) and healthy volunteers (HVs, n = 10) underwent spoiled gradient-echo short-axis cardiac cine MRI studies at 9.4 T (rodents) and 3.0 T (humans). LD measurements were obtained from intrahepatic sub-cardiac regions-of-interest close to the diaphragmatic margin. One-week reproducibility and prandial stress induced hemodynamic changes were assessed in healthy volunteers.
RESULTS: Normalized LD was higher in BDL (1.304 ± 0.062) compared with sham-operated rats (1.058 ± 0.045, P = 0.0031). HV seven-day reproducibility Bland-Altman (BA) limits-of-agreement (LoAs) were ± 0.028 a.u. and inter-reader variability BA LoAs were ± 0.030 a.u. Post-prandial LD increases were non-significant (+ 0.0083 ± 0.0076 a.u., P = 0.3028) and uncorrelated with PV flow changes (r = 0.42, p = 0.2219). LD measurements successfully obtained from all patients were not significantly higher in cirrhotics (0.102 ± 0.0099 a.u.) compared with HVs (0.080 ± 0.0063 a.u., P = 0.0847).
CONCLUSION: Cardiac-induced LD is a conceptually reasonable approach from preclinical studies, measurements demonstrate good reproducibility and inter-reader variability, are less likely to be affected by hepatic hemodynamic changes and are feasible in patients with cirrhosis.
引用
- Chouhan MD, Fitzke HE, Bainbridge A, et al. Cardiac-induced liver deformation as a measure of liver stiffness using dynamic imaging without magnetization tagging-preclinical proof-of-concept, clinical translation, reproducibility and feasibility in patients with cirrhosis. Abdom Radiol (NY). 2021. PMID: 34148103. doi:10.1007/s00261-021-03168-8
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。