基于心动周期内动态变化的人工智能辅助超声心动图对射血分数保留型心力衰竭的预筛查
研究纳入1041例射血分数保留型心力衰竭(HFpEF)患者和1263例无症状个体,从四腔心切面图像逐帧提取几何测量的心动周期内动态变化训练AI模型。最佳模型内部测试准确度0.91、敏感度0.96、特异度0.85;外部测试集(150例症状性慢性阻塞性肺疾病患者和315例HFpEF患者)准确度0.85、敏感度0.79、特异度0.89,内部与外部测试集AUC最高均为0.95。作者认为该AI系统是快速、省时、准确的预筛查方法,可辅助HFpEF诊断。
要点
- AI模型基于四腔心切面逐帧提取的心动周期内几何动态变化检测HFpEF,内部测试敏感度0.96、特异度0.85。
- 外部测试集准确度0.85、敏感度0.79、特异度0.89,内部与外部测试集AUC最高均为0.95。
- 该方法除分类诊断结局外,可自动生成定量指标辅助临床医生诊断HFpEF。
核心结论
- 本研究开发的融入心动周期内动态变化新概念的AI系统是快速、省时、准确的预筛查方法,可促进HFpEF诊断,并能自动生成定量指标辅助临床医生诊断。
研究设计与样本
- 研究纳入1041例HFpEF患者和1263例无症状个体,四腔心切面图像随机分为训练集、验证集和内部测试集;外部测试集包括另一家医院的150例症状性慢性阻塞性肺疾病患者和315例HFpEF患者。
诊断标准与关键数值
- 最佳AI模型检测HFpEF的准确度0.91、敏感度0.96、特异度0.85;外部测试集准确度0.85、敏感度0.79、特异度0.89;内部测试集与外部测试集AUC最高均为0.95。
临床应用与阅片要点
- 作者认为该AI系统可作为快速、省时、准确的预筛查方法促进HFpEF诊断。
- 作者指出该方法除分类诊断结局外可自动生成定量指标辅助临床医生诊断HFpEF。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The aim of this study was to establish a rapid prescreening tool for heart failure with preserved ejection fraction (HFpEF) by using artificial intelligence (AI) techniques to detect abnormal echocardiographic patterns in structure and function on the basis of intrabeat dynamic changes in the left ventricle and the left atrium.
BACKGROUND: Although diagnostic criteria for HFpEF have been established, rapid and accurate assessment of HFpEF using echocardiography remains challenging and highly desirable.
METHODS: In total, 1,041 patients with HFpEF and 1,263 asymptomatic individuals were included in the study. The participants' 4-chamber view images were extracted from the echocardiographic files and randomly separated into training, validation, and internal testing data sets. An external testing data set comprising 150 patients with symptomatic chronic obstructive pulmonary disease and 315 patients with HFpEF from another hospital was used for further model validation. The intrabeat dynamics of the geometric measures were extracted frame by frame from the image sequence to train the AI models.
RESULTS: The accuracy, sensitivity, and specificity of the best AI model for detecting HFpEF were 0.91, 0.96, and 0.85, respectively. The model was further validated using an external testing data set, and the accuracy, sensitivity, and specificity became 0.85, 0.79, and 0.89, respectively. The area under the receiver-operating characteristic curve was used to evaluate model classification ability. The highest area under the curve in the internal testing data set and external testing data set was 0.95.
CONCLUSIONS: The AI system developed in this study, incorporating the novel concept of intrabeat dynamics, is a rapid, time-saving, and accurate prescreening method to facilitate HFpEF diagnosis. In addition to the classification of diagnostic outcomes, such an approach can automatically generate valuable quantitative metrics to assist clinicians in the diagnosis of HFpEF.
引用
- Chiou YA, Hung CL, Lin SF, et al. AI-Assisted Echocardiographic Prescreening of Heart Failure With Preserved Ejection Fraction on the Basis of Intrabeat Dynamics. JACC Cardiovasc Imaging. 2021. PMID: 34147456. doi:10.1016/j.jcmg.2021.05.005
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。