文献速递心血管MR

自配置nnU-net流程实现心肌梗死后晚期增强MRI的梗死灶全自动分割

Self-configuring nnU-net pipeline enables fully automatic infarct segmentation in late enhancement MRI after myocardial infarction.
PubMed 文献 · Eur J Radiol · 2021-06-09

本研究为回顾性单中心研究,纳入78例有心肌梗死病史患者的170次检查,训练自配置nnU-net在晚期钆增强心脏磁共振上分割左心室心肌和梗死区,并以人工标注为参考标准。在10例患者子集中评估,模型对心肌和瘢痕获得较高相似系数,相位敏感与幅度重建或两者联合作为输入间无显著差异,梗死区体积与人工法强相关(r=0.96)但神经网络显著低估体积。

要点

  • 自配置nnU-net可在LGE-CMR上全自动分割左心室心肌和梗死区,与人工分割高度一致。
  • 相位敏感重建、幅度重建或两者联合作为输入时分割精度无显著差异(心肌平均DSC 0.83±0.03,瘢痕0.72±0.08)。
  • 神经网络测得的梗死区体积与人工法强相关(r=0.96),但存在显著低估。

核心结论

  • 自配置nnU-net与人工分割相比获得高度一致的预测,显示出作为LGE-CMR全自动定量评估工具的潜力。

研究设计与样本

  • 回顾性单中心研究,纳入78例有心肌梗死病史患者的170次检查,训练U-Net架构自配置框架nnU-net分割LGE-CMR左心室心肌和梗死区,以人工标注为参考标准,在10例患者子集中评估。

诊断标准与关键数值

  • 以人工标注为参考标准,在10例患者子集中计算Sørensen-Dice相似系数(DSC)并用Pearson r相关和Bland-Altman分析比较梗死区体积;相位敏感重建、幅度重建或两者联合作为输入时,心肌平均DSC为0.83±0.03,瘢痕平均DSC为0.72±0.08。

局限性

  • 本研究为回顾性单中心研究。
  • 仅在10例患者子集中评估模型性能。
  • 神经网络获得的梗死区体积较人工法存在显著低估。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To fully automatically derive quantitative parameters from late gadolinium enhancement (LGE) cardiac MR (CMR) in patients with myocardial infarction and to investigate if phase sensitive or magnitude reconstructions or a combination of both results in best segmentation accuracy.

METHODS: In this retrospective single center study, a convolutional neural network with a U-Net architecture with a self-configuring framework ("nnU-net") was trained for segmentation of left ventricular myocardium and infarct zone in LGE-CMR. A database of 170 examinations from 78 patients with history of myocardial infarction was assembled. Separate fitting of the model was performed, using phase sensitive inversion recovery, the magnitude reconstruction or both contrasts as input channels. Manual labelling served as ground truth. In a subset of 10 patients, the performance of the trained models was evaluated and quantitatively compared by determination of the Sørensen-Dice similarity coefficient (DSC) and volumes of the infarct zone compared with the manual ground truth using Pearson's r correlation and Bland-Altman analysis.

RESULTS: The model achieved high similarity coefficients for myocardium and scar tissue. No significant difference was observed between using PSIR, magnitude reconstruction or both contrasts as input (PSIR and MAG; mean DSC: 0.83 ± 0.03 for myocardium and 0.72 ± 0.08 for scars). A strong correlation for volumes of infarct zone was observed between manual and model-based approach (r = 0.96), with a significant underestimation of the volumes obtained from the neural network.

CONCLUSION: The self-configuring nnU-net achieves predictions with strong agreement compared to manual segmentation, proving the potential as a promising tool to provide fully automatic quantitative evaluation of LGE-CMR.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Heidenreich JF, Gassenmaier T, Ankenbrand MJ, et al. Self-configuring nnU-net pipeline enables fully automatic infarct segmentation in late enhancement MRI after myocardial infarction. Eur J Radiol. 2021. PMID: 34144308. doi:10.1016/j.ejrad.2021.109817

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。