文献速递技术与安全PET

1980-2015年美国放射技师执行普通放射学与核医学操作时的职业辐射剂量趋势

Trends in Occupational Radiation Doses for U.S. Radiologic Technologists Performing General Radiologic and Nuclear Medicine Procedures, 1980-2015.
PubMed 文献 · Radiology · 2021-06-22

该研究汇总了美国放射技师队列中58 434名(62%)从未常规执行介入操作的技师在1980至2015年间的年度个人剂量当量。普通放射学操作相关年剂量中位数从1980年的0.60 mSv降至2015年检测限以下,而核医学操作相关年剂量维持较高水平(中位数1.2 mSv)。更频繁执行诊断核医学、心脏核医学及PET检查与更高且变异性更大的年剂量相关。

要点

  • 普通放射学操作相关年剂量中位数从1980年0.60 mSv降至2015年检测限以下。
  • 核医学操作相关年剂量中位数维持1.2 mSv(IQR 0.12-3.0 mSv),高于普通放射学。
  • 心脏核医学(≥10次/周)和PET(≥9次/周)操作与更高且更多变的年剂量相关。

核心结论

  • 美国放射技师执行普通放射学操作的年剂量在36年间下降;但执行核医学操作,尤其是心脏核医学和PET操作,与持续更高且变异性更大的剂量相关。

研究设计与样本

  • 研究汇总了美国放射技师(USRT)队列中58 434名(62%)对最近一次邮寄工作史调查(2012-2014年)应答且报告从未常规执行介入操作的参与者的1980至2015年年度个人剂量当量,按日历年及是否执行核医学(频率、操作类型)分层,采用中位数及第25、75百分位数等汇总统计描述。

诊断标准与关键数值

  • 普通放射学操作相关年剂量中位数从1980年的0.60 mSv(IQR 0.10-1.9 mSv)降至2015年检测限以下。
  • 核医学操作相关年剂量中位数在该期间维持1.2 mSv(IQR 0.12-3.0 mSv)。
  • 诊断核医学操作频率≥35次/周者年剂量中位数1.6 mSv(IQR 0.30-3.3 mSv),<35次/周者0.9 mSv(IQR 0.10-2.6 mSv)。
  • 心脏核医学操作≥10次/周者年剂量中位数1.6 mSv(IQR 0.30-2.2 mSv)。
  • PET操作≥9次/周者年剂量中位数2.2 mSv(IQR 0.10-4.6 mSv)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background Occupational doses to most medical radiation workers have declined substantially since the 1950s because of improvements in radiation protection practices. However, different patterns may have emerged for radiologic technologists working with nuclear medicine because of the higher per-procedure doses and increasing workloads. Purpose To summarize annual occupational doses during a 36-year period for a large cohort of U.S. radiologic technologists and to compare dose between general radiologic technologists and those specializing in nuclear medicine procedures. Materials and Methods Annual personal dose equivalents (referred to as doses) from 1980 to 2015 were summarized for 58 434 (62%) participants in the U.S. Radiologic Technologists (USRT) cohort who responded to the most recent mailed work history survey (years 2012-2014) and reported never regularly performing interventional procedures. Doses were partitioned according to the performance of nuclear medicine (yes or no, frequency, procedure type) by calendar year. Annual dose records were described by using summary statistics (eg, median and 25th and 75th percentiles). Results Median annual doses related to performance of general radiologic procedures decreased from 0.60 mSv (interquartile range [IQR], 0.10-1.9 mSv) in 1980 to levels below the limits of detection by 2015, whereas annual doses related to performance of nuclear medicine procedures remained relatively high during this period (median, 1.2 mSv; IQR, 0.12-3.0 mSv). Higher median annual doses were associated with more frequent (above vs below the median) performance of diagnostic nuclear medicine procedures (≥35 vs <35 times per week; 1.6 mSv [IQR, 0.30-3.3 mSv] and 0.9 mSv [IQR, 0.10-2.6 mSv]). Higher and more variable annual doses were associated with more frequent performance of cardiac nuclear medicine (≥10 times per week) and PET (nine or more times per week) examinations (median, 1.6 mSv [IQR, 0.30-2.2 mSv] and 2.2 mSv [IQR, 0.10-4.6 mSv], respectively). Conclusion Annual doses to U.S. radiologic technologists performing general radiologic procedures declined during a 36-year period. However, consistently higher and more variable doses were associated with the performance of nuclear medicine procedures, particularly cardiac nuclear medicine and PET procedures. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Mettler and Guiberteau in this issue.

来源:Radiology,查看原文。版权归原作者所有。

引用

  1. Villoing D, Borrego D, Preston DL, et al. Trends in Occupational Radiation Doses for U.S. Radiologic Technologists Performing General Radiologic and Nuclear Medicine Procedures, 1980-2015. Radiology. 2021. PMID: 34156301. doi:10.1148/radiol.2021204501

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。