减影技术提高冠状动脉CT血管成像在严重钙化节段中检测阻塞性病变的准确性

Subtraction improves the accuracy of coronary CT angiography for detecting obstructive disease in severely calcified segments.
PubMed 文献 · Eur Radiol · 2021-06-17

前瞻性纳入64例疑似冠心病患者,以有创冠状动脉造影为参考,比较减影冠状动脉CT血管成像与常规CCTA在钙化节段中的诊断准确性、诊断信心和观察者间一致性。严重钙化( circumferential extent ≥180°)时减影CCTA的AUC、诊断信心和观察者间一致性均更优;非严重钙化(<180°)时减影未提高诊断准确性。

要点

  • 严重钙化( circumferential extent ≥180°)节段,减影CCTA较常规CCTA提高诊断准确性(每患者AUC 0.73 vs 0.57,p=0.03;每节段AUC 0.85 vs 0.62,p=0.01)。
  • 严重钙化节段,减影CCTA诊断信心更高(3.7 vs 2.6,p<0.001),观察者间一致性更好(κ=0.59 vs 0.30)。
  • 非严重钙化(<180°)节段,减影CCTA未提高诊断准确性(每患者AUC 0.81 vs 0.93,p=0.30;另一每患者AUC 0.79 vs 0.82,p=0.54)。

核心结论

  • 减影CCTA在严重钙化( circumferential extent ≥180°)病例中诊断准确性更优,但在非严重钙化(<180°)中钙减影效果不明确,未提高诊断准确性。

研究设计与样本

  • 前瞻性纳入2019年10月至2020年6月64例疑似冠心病患者(33例男性,66.6±8.2岁),采用320排CT行CCTA,以有创冠状动脉造影为参考标准;根据钙化横断面圆周范围将钙化节段分为非严重(<180°)和严重(≥180°);三位独立盲法放射科医师评估狭窄程度。

诊断标准与关键数值

  • 以狭窄≥50%为截断值;严重钙化(51例患者,146个节段)减影CCTA每患者AUC 0.73 vs 常规CCTA 0.57(p=0.03),每节段AUC 0.85 vs 0.62(p=0.01),诊断信心3.7 vs 2.6(p<0.001),观察者间一致性κ 0.59 vs 0.30;非严重钙化(13例患者,190个节段)每患者AUC 0.81 vs 0.93(p=0.30)和每患者AUC 0.79 vs 0.82(p=0.54),诊断准确性未提高。

临床应用与阅片要点

  • 在严重钙化( circumferential extent ≥180°)节段,阅片时可参考减影CCTA信息以提高诊断准确性、诊断信心和观察者间一致性;非严重钙化(<180°)时钙减影效果不明确,未提高诊断准确性。

局限性

  • 对于非严重钙化( circumferential extent <180°),钙减影的效果不明确,因其未提高诊断准确性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: To investigate the accuracy, diagnostic confidence, and interobserver agreement of subtraction coronary CT angiography (CCTA) versus invasive coronary angiography on 320-row CT in coronary segments with severe or non-severe calcification.

MATERIALS/METHODS: Sixty-four patients (33 men, 66.6 ± 8.2 years) with suspected coronary artery disease (CAD) were prospectively enrolled from October 2019 to June 2020. The cross-sectional circumferential extent of calcification was used to classify calcified segments as non-severely ( < 180°) or severely calcified ( ≥ 180°). Three independent, blinded radiologists evaluated the severity of coronary stenosis. Interobserver agreement was evaluated using Fleiss' kappa (κ). A multiple-reader multiple-case receiver operating characteristic (ROC) method was conducted, and diagnostic accuracy was measured using the mean areas under the ROC curves (AUCs), with ≥ 50% stenosis as a cut-off. Diagnostic confidence, diagnostic accuracy, and interobserver agreement were compared between CCTA with or without subtraction information in severely and non-severely calcified segments.

RESULTS: In cases with severe calcification (51 patients, 146 segments), CCTA with subtraction information achieved better diagnostic accuracy (per-patient AUC: 0.73 vs 0.57, p = 0.03; per-segment AUC: 0.85 vs 0.62, p = 0.01), diagnostic confidence (3.7 vs 2.6, p < 0.001), and interobserver agreement (κ: 0.59 vs 0.30). Diagnostic accuracy (per-patient AUC: 0.81 vs 0.93, p = 0.30; per-patient AUC: 0.79 vs 0.82, p = 0.54) was not increased in cases with non-severe calcification (13 patients, 190 segments).

CONCLUSIONS: CCTA with subtraction information achieved better diagnostic accuracy in cases of severe calcification (circumferential extent ≥ 180°). However, for non-severe calcification (circumferential extent < 180°), the effect of calcium subtraction was unclear, as it did not improve diagnostic accuracy.

KEY POINTS: • Subtraction coronary CT angiography achieves better diagnostic accuracy, higher diagnostic confidence, and increased interobserver agreement for severe calcification (circumferential extent ≥ 180°). • Calcium subtraction does not improve the diagnostic accuracy of coronary CT angiography for calcification with a circumferential extent of < 180°.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Xu L, Li F, Wu K, et al. Subtraction improves the accuracy of coronary CT angiography for detecting obstructive disease in severely calcified segments. Eur Radiol. 2021. PMID: 34142220. doi:10.1007/s00330-021-08092-5

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。