文献速递心血管CTDSA

校正FFRCT指标对血流动力学显著冠状动脉狭窄的诊断效能

Diagnostic performance of corrected FFRCT metrics to predict hemodynamically significant coronary artery stenosis.
PubMed 文献 · Eur Radiol · 2021-06-02

本研究回顾性纳入73例疑似冠心病患者,在1个月内完成CCTA和侵入性冠状动脉造影,计算跨病变ΔFFRCT、跨血管ΔFFRCT和FFRCT梯度,评估其诊断血流动力学显著狭窄的效能;跨病变ΔFFRCT的敏感度94.4%、特异度88.7%、准确率91.0%,诊断效能最佳,冠状动脉钙化对校正FFRCT指标无影响。

要点

  • 跨病变ΔFFRCT诊断血流动力学显著狭窄的敏感度94.4%、特异度88.7%、准确率91.0%。
  • 跨病变ΔFFRCT的特异度、准确率和AUC均高于CCTA(p < 0.05)。
  • 冠状动脉钙化对校正FFRCT指标无影响,病变长度与跨病变ΔFFRCT相关。

核心结论

  • 跨病变ΔFFRCT与血流动力学显著冠状动脉狭窄显著相关,有潜力直接用于临床实践鉴别缺血性冠状动脉狭窄。

研究设计与样本

  • 回顾性研究,2016年6月至2018年12月纳入73例疑似冠心病患者,均行CCTA并在1个月内行侵入性冠状动脉造影(ICA)。

关键影像表现/征象

  • 跨病变ΔFFRCT诊断血流动力学显著狭窄的敏感度94.4%、特异度88.7%、准确率91.0%。
  • 跨血管ΔFFRCT诊断血流动力学显著狭窄的敏感度57.1%、特异度72.3%、准确率65.2%。
  • FFRCT梯度诊断血流动力学显著狭窄的敏感度50.0%、特异度85.1%、准确率68.5%。

诊断标准与关键数值

  • 跨病变ΔFFRCT诊断血流动力学显著狭窄的敏感度94.4%、特异度88.7%、准确率91.0%。
  • 跨血管ΔFFRCT诊断血流动力学显著狭窄的敏感度57.1%、特异度72.3%、准确率65.2%。
  • FFRCT梯度诊断血流动力学显著狭窄的敏感度50.0%、特异度85.1%、准确率68.5%。
  • 跨病变ΔFFRCT的特异度、准确率和AUC均高于CCTA(p < 0.05)。
  • FFRCT梯度和跨血管ΔFFRCT的特异度和AUC均显著高于CCTA(p < 0.05)。

临床应用与阅片要点

  • 跨病变ΔFFRCT有潜力直接用于临床实践鉴别缺血性冠状动脉狭窄。
  • 冠状动脉钙化对校正FFRCT指标无影响。
  • 病变长度与跨病变ΔFFRCT相关:病变长度比<1/10的ΔFFRCT显著低于病变长度比1/10至3/10和>3/10。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To determine the diagnostic performance of the fractional flow reserve (FFR) derived from coronary computed tomography angiography (CCTA) (FFRCT) difference across the lesion (ΔFFRCT lesion) or the vessel (ΔFFRCT vessel) and the gradient of FFRCT for the identification of hemodynamically significant coronary stenosis.

METHODS: From June 2016 to December 2018, 73 patients suspected of having coronary artery disease who underwent CCTA followed invasive coronary angiography (ICA) within 1 month were retrospectively included. ΔFFRCT lesion, ΔFFRCT vessel, and FFRCT gradient were calculated. Performance characteristics of different corrected FFRCT metrics in detecting ischemic stenosis were analyzed. Impacts of coronary calcification and lesion length on the corrected FFRCT metrics were also analyzed.

RESULTS: The diagnostic sensitivities, specificities, and accuracies of 94.4%, 88.7%, and 91.0% with ΔFFRCT lesion, 57.1%, 72.3%, and 65.2% with ΔFFRCT vessel, and 50.0%, 85.1%, and 68.5% with FFRCT gradient, respectively, were detected. There was higher specificity, accuracy, and area under the curve (AUC) for ΔFFRCT lesion compared with CCTA (p < 0.05 for all). The specificity and AUC of FFRCT gradient and ΔFFRCT vessel were significantly higher than CCTA (p < 0.05 for all). Coronary calcification showed no impact on corrected FFRCT metrics. ΔFFRCT lesion for lesion length ratio (LLR) < 1/10 was significantly lower than that for LLR 1/10 to 3/10 and LLR > 3/10.

CONCLUSIONS: ΔFFRCT lesion was significantly correlated with the hemodynamically significant coronary artery stenosis. ΔFFRCT lesion had the potential to be immediately used in real-world practice to discriminate ischemic coronary artery stenosis.

KEY POINTS: • The difference of FFRCT across the lesion or the vessel and the gradient of FFRCT was related to the hemodynamically significant coronary artery stenosis. • The difference of FFRCT across the lesion showed the best diagnostic performance in detecting the hemodynamically significant coronary artery stenosis. • Coronary calcification showed no impact on corrected FFRCT metrics, while lesion length related to the difference of FFRCT across the lesion.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Wen D, Zhao H, Zhong S, et al. Diagnostic performance of corrected FFRCT metrics to predict hemodynamically significant coronary artery stenosis. Eur Radiol. 2021. PMID: 34080038. doi:10.1007/s00330-021-08064-9

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。