文献速递技术与安全MR

改善金属植入物患者的MR图像质量

Improving MR Image Quality in Patients with Metallic Implants.
PubMed 文献 · Radiographics · 2021-06-18

随着植入装置数量增加,许多患者需行MRI检查,但含顺磁性或铁磁性物质的植入物可产生显著伪影,限制诊断能力。本文综述了从确认植入物安全性、选择MRI系统、患者体位、调整MRI参数及选择减少金属伪影序列等技术,以改善图像质量和诊断信心。

要点

  • 检查前确认植入物存在是确保患者处于强磁场中安全的关键。
  • 选择预期提供最佳图像质量的MRI系统,需考虑场强效应和特定序列的可用性。
  • 合理体位、调整带宽/体素大小/回波等参数及选择金属伪影少的序列可改善图像质量。

核心结论

  • 通过适当规划和理解如何最小化伪影,金属植入物患者可成功接受MRI检查,从而提高图像质量和放射科医生的诊断信心。

研究设计与样本

  • 本文为综述,检索范围与纳入文献原文未报告。

临床应用与阅片要点

  • 患者到达前了解植入物存在对确保安全至关重要。
  • 在确保安全后,应使用预期提供最佳图像质量的MRI系统进行检查。
  • 选择MRI系统需考虑场强效应和可减少金属伪影的特定序列的可用性。
  • 注意患者体位、MRI参数(包括带宽、体素大小和回波)以及选择金属伪影较少的序列和先进金属减少序列。

局限性

  • 原文未报告局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

The number of implanted devices such as orthopedic hardware and cardiac implantable devices continues to increase with an increase in the age of the patient population, as well as an increase in the number of indications for specific devices. Many patients with these devices have or will develop clinical conditions that are best depicted at MRI. However, implanted devices containing paramagnetic or ferromagnetic substances can cause significant artifact, which could limit the diagnostic capability of this modality. Performing imaging with MRI when an implant is present may be challenging, and there are numerous techniques the radiologist and technologist can use to help minimize artifacts related to implants. First, knowledge of the presence of an implant before patient arrival is critical to ensure safety of the patient when the device is subjected to a strong magnetic field. Once safety is ensured, the examination should be performed with the MRI system that is expected to provide the best image quality. The selection of the MRI system includes multiple considerations such as the effects of field strength and availability of specific sequences, which can reduce metal artifact. Appropriate patient positioning, attention to MRI parameters (including bandwidth, voxel size, and echo), and appropriate selection of sequences (those with less metal artifact and advanced metal reduction sequences) are critical to improve image quality. Patients with implants can be successfully imaged with MRI with appropriate planning and understanding of how to minimize artifacts. This improves image quality and the diagnostic confidence of the radiologist. ©RSNA, 2021.

来源:Radiographics,查看原文。版权归原作者所有。

引用

  1. Lee EM, Ibrahim EH, Dudek N, et al. Improving MR Image Quality in Patients with Metallic Implants. Radiographics. 2021. PMID: 34143712. doi:10.1148/rg.2021200092

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。