人工智能在超声心动图中自动测量左心室应变
本研究纳入200例左心室功能范围广泛的患者,评估基于深度学习和人工智能的全自动整体纵向应变(GLS)测量方法,并与半自动斑点追踪软件EchoPAC v202比较;AI方法在89%患者中正确分类三个标准心尖切面并完成心脏事件时序,全自动GLS为-12.0±4.1%,参考方法为-13.5±5.3%,偏差-1.4±0.3%(95%一致性界限2.3至-5.1),AI方法消除测量变异性且完整分析在15秒内完成。
要点
- AI方法在89%患者中正确识别三个标准心尖切面并完成心脏事件时序。
- AI全自动GLS为-12.0±4.1%,参考方法为-13.5±5.3%,偏差-1.4±0.3%(95%一致性界限2.3至-5.1)。
- AI方法消除测量变异性,完整GLS分析在15秒内完成。
核心结论
- 该新型AI方法在左心室功能范围内无需操作者输入即可自动识别三个标准心尖切面、完成心脏事件时序、追踪心肌、进行运动估计并测量GLS;基于AI的全自动测量可能促进GLS的临床实施。
研究设计与样本
- 研究纳入200例左心室功能范围广泛的患者,分析三个标准心尖 cine-loop,使用基于深度学习和人工智能的运动估计算法全自动测量GLS,并与商用半自动斑点追踪软件EchoPAC v202(GE Healthcare)比较。
诊断标准与关键数值
- AI方法在89%患者中成功正确分类全部三个标准心尖切面并完成心脏事件时序;AI方法GLS为-12.0±4.1%,参考方法GLS为-13.5±5.3%;偏差为-1.4±0.3%(95%一致性界限:2.3至-5.1)。
临床应用与阅片要点
- 作者认为基于AI的全自动测量可能促进GLS的临床实施;AI方法可消除测量变异性,完整GLS分析在15秒内完成。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: This study sought to examine if fully automated measurements of global longitudinal strain (GLS) using a novel motion estimation technology based on deep learning and artificial intelligence (AI) are feasible and comparable with a conventional speckle-tracking application.
BACKGROUND: GLS is an important parameter when evaluating left ventricular function. However, analyses of GLS are time consuming and demand expertise, and thus are underused in clinical practice.
METHODS: In this study, 200 patients with a wide range of left ventricle (LV) function were included. Three standard apical cine-loops were analyzed using the AI pipeline. The AI method measured GLS and was compared with a commercially available semiautomatic speckle-tracking software (EchoPAC v202, GE Healthcare.
RESULTS: The AI method succeeded to both correctly classify all 3 standard apical views and perform timing of cardiac events in 89% of patients. Furthermore, the method successfully performed automatic segmentation, motion estimates, and measurements of GLS in all examinations, across different cardiac pathologies and throughout the spectrum of LV function. GLS was -12.0 ± 4.1% for the AI method and -13.5 ± 5.3% for the reference method. Bias was -1.4 ± 0.3% (95% limits of agreement: 2.3 to -5.1), which is comparable with intervendor studies. The AI method eliminated measurement variability and a complete GLS analysis was processed within 15 s.
CONCLUSIONS: Through the range of LV function this novel AI method succeeds, without any operator input, to automatically identify the 3 standard apical views, perform timing of cardiac events, trace the myocardium, perform motion estimation, and measure GLS. Fully automated measurements based on AI could facilitate the clinical implementation of GLS.
引用
- Salte IM, Østvik A, Smistad E, et al. Artificial Intelligence for Automatic Measurement of Left Ventricular Strain in Echocardiography. JACC Cardiovasc Imaging. 2021. PMID: 34147442. doi:10.1016/j.jcmg.2021.04.018
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。