CT引导下磨玻璃结节术前定位:栓塞微弹簧圈与肺结节定位针的应用比较
研究纳入2019年6月至2020年12月429例单发磨玻璃结节(GGN)患者,在电视辅助胸腔镜手术(VATS)前接受CT引导下定位,前221枚用微弹簧圈、后208枚用肺结节定位针。定位针组定位时间更短、成功率更高,两组总并发症及气胸、出血、咯血发生率无显著差异。
要点
- 肺结节定位针组定位成功率98.6%,高于微弹簧圈组的91.4%。
- 定位针组定位时间8.2±2.0 min,短于微弹簧圈组的11.1±3.9 min。
- 两组总并发症、气胸、出血、咯血发生率无显著差异,均为轻微并发症。
核心结论
- 使用栓塞微弹簧圈或肺结节定位针行GGN术前定位均安全有效;定位针在操作时间和成功率方面优于微弹簧圈,两组并发症发生率相似。
研究设计与样本
- 2019年6月至2020年12月纳入429例VATS术前接受CT引导下单发GGN定位的患者,前221枚GGN用微弹簧圈标记(微弹簧圈组),其余208枚用肺结节定位针标记(定位针组)。
关键影像表现/征象
- GGN直径为0.84±0.39 cm,深度为1.66±1.37 cm。
- 微弹簧圈组定位失败包括16例微弹簧圈脱位和3例微弹簧圈位置不理想。
- 定位针组3例定位失败均为锚定位置不理想。
- 除微弹簧圈组1例中转开胸外,其余428枚GGN均经VATS成功切除。
诊断标准与关键数值
- 微弹簧圈组定位成功率91.4%,定位针组98.6%(χ2=11.27,p=0.001)。
- 微弹簧圈组定位时间11.1±3.9 min,定位针组8.2±2.0 min(t=-7.87,p=0.000)。
- 两组总并发症发生率23.1% vs 22.1%,气胸18.1% vs 19.2%,出血9.5% vs 9.1%,咯血1.8% vs 1.4%,均无显著差异。
临床应用与阅片要点
- 定位针结构可有效避免定位后脱位,标记过程简单快捷。
- 与微弹簧圈定位相比,使用定位针标记GGN耗时更少、成功率更高。
- 两种方法并发症发生率相似,均为轻微并发症且无需特殊处理。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To compare the efficacy and safety of pre-operative localization of ground glass nodule (GGN) using embolization microcoils and the locating needles designed for pulmonary nodules.
METHODS: From June 2019 to December 2020, 429 patients who received CT-guided localization of single GGN before video-assisted thoracoscopic surgery (VATS) were enrolled. The diameter and depth of GGNs were 0.84 ± 0.39 cm and 1.66 ± 1.37 cm. Among 429 cases, the first 221 GGNs were marked with microcoils (the microcoil group), and the remaining 208 GGNs were marked with the locating needles designed for pulmonary nodules (the locating needle group). SPSS 17.0 statistical software was used to compare the marking success rate, marking time, marking-related complications between two groups. p values < 0.05 were considered statistically significant.
RESULTS: The marking time in the microcoil group was longer than that in the locating needle group (11.1 ± 3.9 vs 8.2 ± 2.0 min, t = -7.87, p = 0.000). The marking success rate in the microcoil group was lower than that in the locating needle group (91.4% vs 98.6%, χ2 = 11.27, p = 0.001). In the microcoil group, marking failures included 16 cases of microcoil dislocation and 3 cases of unsatisfactory microcoil position, while all 3 cases of marking failure in the locating needle group were due to unsatisfactory anchor position. No significant differences in the incidence of total complications (23.1% vs 22.1%), pneumothorax (18.1% vs 19.2%), hemorrhage (9.5% vs 9.1%), and hemoptysis (1.8% vs 1.4%) were observed between the two groups. All the complications were minor and did not need special treatment. Except for one case in the microcoil group, which was converted to thoracotomy, the remaining 428 GGNs were successfully resected by VATS.
CONCLUSIONS: It is safe and effective to perform pre-operative localization of GGN using either embolization microcoil or the locating needle designed for pulmonary nodules. The locating needle is superior to microcoil for marking GGN in terms of procedure time and the success rate. The complication rate of both methods is similar.
ADVANCES IN KNOWLEDGE: The locating needle designed for pulmonary nodules has recently been used to mark pulmonary nodule. Its structure can effectively avoid dislocation after localization, and the marking process is simple and quick. Compared with localization using microcoil, it takes less time and has higher success rate to mark GGNs using the locating needle. The complication rate of both methods is similar.
引用
- Li CD, Huang ZG, Sun HL, et al. CT-guided preoperative localization of ground glass nodule: comparison between the application of embolization microcoil and the locating needle designed for pulmonary nodules. Br J Radiol. 2021. PMID: 34111980. doi:10.1259/bjr.20210193
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。