高分辨率CT上纯磨玻璃影大于3厘米的肺腺癌的临床病理研究
本研究纳入2007年6月至2015年10月间69例切除的纯磨玻璃影大于3厘米且随访至少5年的病例,分为原位腺癌或微浸润腺癌组(13例)与浸润性腺癌组(56例),发现平均CT衰减值是术前鉴别的唯一显著预测因子,最佳截断值-600 HU,AUC 0.981,敏感度87.5%、特异度100%,所有患者5年无复发生存率和总生存率均为100%。
要点
- 纯磨玻璃影大于3厘米的肺腺癌仍可能为原位腺癌或微浸润腺癌。
- 平均CT衰减值是术前鉴别浸润性腺癌与原位/微浸润腺癌的唯一显著CT参数。
- 所有纯磨玻璃影大于3厘米患者5年无复发生存率和总生存率均为100%。
核心结论
- 纯磨玻璃影大于3厘米的肺腺癌仍可能为原位腺癌或微浸润腺癌,平均CT衰减值可能是术前鉴别的唯一有价值参数,且此类患者预后极佳。
研究设计与样本
- 回顾性纳入2007年6月至2015年10月间69例切除的纯磨玻璃影大于3厘米病例,均有高分辨率CT且随访至少5年,分为原位腺癌或微浸润腺癌组(n=13)与浸润性腺癌组(n=56),采用Firth逻辑回归分析CT特征,以AUC评价预测效能,并评估疾病复发。
诊断标准与关键数值
- 平均CT衰减值鉴别浸润性腺癌与原位/微浸润腺癌的比值比为1.054(p=0.0087),AUC为0.981,最佳截断值为-600 HU,敏感度87.5%、特异度100%。
临床应用与阅片要点
- 原文结论指出,临床实践中遇到纯磨玻璃影大于3厘米时,CT值可能是术前区分浸润性腺癌与原位/微浸润腺癌的唯一有价值参数。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: This study aimed to discuss whether a diameter of 3 cm is a threshold for diagnosing lung adenocarcinomas presenting with radiological pure ground-glass mass (PGGM, pure ground-glass opacity > 3 cm) as adenocarcinomas in situ or minimally invasive adenocarcinomas (AIS-MIAs). Another aim was to identify CT features and patient prognosis that differentiate AIS-MIAs from invasive adenocarcinomas (IACs) in patients with PGGMs.
METHODS: From June 2007 to October 2015, 69 resected PGGMs with HRCT and followed up for ≥ 5 years were included in this study and divided into AIS-MIA (n = 13) and IAC (n = 56) groups. Firth's logistic regression model was performed to determine CT characteristics that helped distinguish IACs from AIS-MIAs. The discriminatory power of the significant predictors was tested with the area under the receiver operating characteristics curve (AUC). Disease recurrence was also evaluated.
RESULTS: Univariable and multivariable analyses identified that the mean CT attenuation (odds ratio: 1.054, p = 0.0087) was the sole significant predictor for preoperatively discriminating IACs from AIS-MIAs in patients with PGGMs. The CT attenuation had an excellent differentiating accuracy (AUC: 0.981), with the optimal cut-off value at -600 HU (sensitivity: 87.5%; specificity: 100%). Additionally, no recurrence was observed in patients manifesting with PGGMs > 3 cm, and the 5-year recurrence-free survival and overall survival rates were both 100%, even in cases of IAC.
CONCLUSIONS: This study demonstrated that PGGMs > 3 cm could still be AIS-MIAs. When PGGMs are encountered in clinical practice, the CT value may be the only valuable parameter to preoperatively distinguish IACs from AIS-MIAs.
KEY POINTS: • Patients with pure ground-glass opacity > 3 cm in diameter are rare but can be diagnosed as adenocarcinomas in situ or minimally invasive adenocarcinomas. • The mean CT attenuation is the sole significant CT parameter that differentiates invasive adenocarcinoma from adenocarcinoma in situ or minimally invasive adenocarcinoma in patients with pure ground-glass opacity > 3 cm. • Lung adenocarcinoma with pure ground-glass opacity > 3 cm has an excellent prognosis, even in cases of invasive adenocarcinoma.
引用
- Sun K, Xie H, Zhao J, et al. A clinicopathological study of lung adenocarcinomas with pure ground-glass opacity > 3 cm on high-resolution computed tomography. Eur Radiol. 2021. PMID: 34132876. doi:10.1007/s00330-021-08115-1
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。