CT引导下氰基丙烯酸酯注射用于同侧多发肺结节定位
回顾性纳入81例169个病灶行CT引导氰基丙烯酸酯定位的同侧多发小肺结节患者(M组),与同期284例单发结节定位患者(S组)行倾向性评分匹配。M组定位操作时间显著更长、气胸发生率更高,但定位与手术成功率、疼痛评分及追加吗啡用量与S组无显著差异;体位改变是气胸的独立危险因素。
要点
- 同侧多发小肺结节CT引导氰基丙烯酸酯定位技术成功率高,定位与手术成功率分别为100%和98.8%。
- 与单发结节定位相比,多发结节定位操作时间更长且气胸发生率更高。
- 体位改变是气胸的独立危险因素,风险约增加七倍(p=0.001)。
核心结论
- CT引导氰基丙烯酸酯注射用于同侧多发小肺结节定位安全可靠,允许灵活安排手术,尽管操作时间较长且气胸发生率增加;避免体位改变可能有助于减少气胸发生。
研究设计与样本
- 回顾性研究,纳入2016年9月至2020年7月行CT引导氰基丙烯酸酯定位的同侧多发小肺结节患者81例(169个病灶,M组),另以同期接受单发结节定位的284例患者为对照组(S组),采用倾向性评分分析减少选择偏倚,并用多因素logistic回归分析气胸的独立预测因素。
诊断标准与关键数值
- M组81例患者均成功完成同侧多发结节定位,定位操作成功率100%,手术成功率98.8%。
- 倾向性匹配后形成81对患者,两组定位与手术成功率、定位相关疼痛评分及追加吗啡用量均无显著差异。
- M组定位操作时间显著长于S组(p<0.001),气胸发生率显著高于S组(p<0.001)。
- 多因素分析显示体位改变与气胸风险增加七倍显著相关(p=0.001)。
临床应用与阅片要点
- M组77例(95.1%)在手术前一天接受定位操作。
- 作者认为避免体位改变可能有助于减少气胸发生。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To retrospectively assess the clinical effectiveness of CT-guided cyanoacrylate localization for multiple ipsilateral small pulmonary nodules (SPNs) and to determine the independent predictors for pneumothorax.
METHODS: In total, 81 patients with 169 lesions undergoing CT-guided cyanoacrylate localization for multiple ipsilateral SPNs between September 2016 and July 2020 were enrolled (group M). Another 284 patients who received single SPN localization during the same period served as the control group (group S). Propensity score analysis was performed to minimize selection bias. Possible independent predictors for pneumothorax were evaluated using multivariate logistic regression analysis.
RESULTS: Multiple ipsilateral SPN localization was successfully performed in all 81 patients. The incidences of successful targeting during localization and surgery were 100% and 98.8%, respectively. Seventy-seven patients (95.1%) underwent the procedure on the day before the surgery. Propensity matching created 81 pairs of patients. There were no significant differences in the incidence of successful targeting during localization and surgery, localization-related pain score, and additional morphine use between the two groups. However, group M was associated with a significant longer localization procedural time (p < 0.001) and a higher incidence of pneumothorax (p < 0.001). In multivariate analysis, position change was significantly associated with a sevenfold increase in the risk for pneumothorax (p = 0.001).
CONCLUSIONS: CT-guided cyanoacrylate injection for multiple ipsilateral SPN localization was safe and reliable, and allowed a flexible surgical schedule, despite a lengthy procedure and an increased incidence of pneumothorax. Avoiding position change may help to reduce the occurrence of pneumothorax.
KEY POINTS: • Compared to single SPN localization, multiple ipsilateral SPN localization using cyanoacrylate injection achieved comparable safety, reliability, and comfort. • CT-guided cyanoacrylate localization for multiple ipsilateral SPNs allowed a flexible surgical schedule. • Position change was the only independent risk factor for pneumothorax during the multiple ipsilateral SPN localization.
引用
- Xu L, Wang J, Liu L, et al. Computed tomography-guided cyanoacrylate injection for localization of multiple ipsilateral lung nodules. Eur Radiol. 2021. PMID: 34170364. doi:10.1007/s00330-021-08101-7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。