文献速递胸部技术与安全USCT

超声引导胸腔造口术定位的新方法

Novel Approach to Ultrasound-Guided Thoracostomy.
PubMed 文献 · J Ultrasound Med · 2021-06-04

该随机前瞻性研究将急诊科住院医师随机分配至触诊组或超声组,为血流动力学稳定的创伤患者(均接受扩大创伤重点超声评估和胸部CT)在皮肤上标记胸腔造口安全插入点,并以CT确认标记相对膈肌的位置。超声组膈肌上方正确识别率为97.2%(138/142),触诊组为88.4%(114/129),差异有统计学意义(P=0.0073)。

要点

  • 超声组膈肌上方正确识别率为97.2%(138/142),触诊组为88.4%(114/129),P=0.0073。
  • 研究纳入147例创伤患者,共放置271个造口部位标记,超声组142个,触诊组129个。
  • 急诊科住院医师使用超声较触诊和体表标志更可能识别安全的胸腔造口插入部位。

核心结论

  • 急诊科住院医师使用超声较使用体表标志和触诊更可能在创伤患者中识别安全的胸腔置管造口插入部位。

研究设计与样本

  • 随机前瞻性研究,纳入147例血流动力学稳定的创伤患者(超声组75例,触诊组72例),患者均接受扩大创伤重点超声评估(EFAST)和胸部CT检查;住院医师随机采用触诊或超声在皮肤放置不透射线标记,由临床超声教员审阅CT确认标记相对膈肌的位置。

诊断标准与关键数值

  • 超声组正确识别膈肌上方胸腔造口插入部位的比例为97.2%(138/142),触诊组为88.4%(114/129),P=0.0073。

临床应用与阅片要点

  • 急诊科住院医师可采用超声辅助识别胸腔造口的安全插入部位,较传统体表标志和触诊更可能将标记置于膈肌上方。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Thoracostomy is often a required treatment in patients with thoracic trauma; however, performing a thoracostomy using traditional techniques can have complications. Ultrasound can be a beneficial tool for identifying the correct thoracostomy insertion site. We designed a randomized prospective study to assess if ultrasound guidance can improve thoracostomy site identification over traditional techniques.

METHODS: Emergency medicine residents were randomly assigned to use palpation or ultrasound to identify a safe insertion site for thoracostomy placement. The target population comprised of hemodynamically stable trauma patients who received an extended focused assessment with sonography for trauma (EFAST) and a chest computed tomography (CT) exam. The resident placed a radiopaque marker on the skin of the patient where a safe intercostal space was believed to be located, either by palpation or ultrasound. Clinical ultrasound faculty reviewed the CT to confirm marker placement relative to the diaphragm. A Fischer's exact test was used to analyze the groups.

RESULTS: One hundred and forty-seven patients were enrolled in the study, 75 in the ultrasound group and 72 in the landmark group. This resulted in the placement of 271 total thoracostomy site markers, 142 by ultrasound and 129 by palpation and landmarks. The ultrasound group correctly identified thoracostomy insertion sites above the diaphragm in 97.2% (138/142) of patients, while the palpation group identified a safe insertion site in 88.4% (114/129) of patients (P = .0073).

CONCLUSION: This study found that emergency medicine residents are more likely to identify a safe tube thoracostomy insertion site in trauma patients by using ultrasound, as compared to using landmarks and palpation.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Taylor LA, Stenberg R, Tozer J, et al. Novel Approach to Ultrasound-Guided Thoracostomy. J Ultrasound Med. 2021. PMID: 34086998. doi:10.1002/jum.15759

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。