研究纳入22例患者37耳临床诊断耳海绵化症及22例对照35耳,采用颞骨锥形束CT测量卵圆窗前区、外半规管骨岛及邻近含气腔的像素值,计算相对衰减比。耳海绵化症组相对衰减比显著低于对照组(P < .001),ROC分析最佳截断值0.876,诊断准确率97.2%。结论认为内校准像素值比值可客观辅助诊断活动性/海绵期窗型耳硬化症。

要点

  • 卵圆窗前区相对衰减比在耳海绵化症组显著低于对照组(P < .001)。
  • 最佳截断值0.876,诊断耳海绵化症准确率97.2%。
  • 内校准像素值比值可客观辅助诊断活动性/海绵期窗型耳硬化症。

核心结论

  • 颞骨锥形束CT内校准像素值比值可客观辅助诊断活动性/海绵期窗型耳硬化症。

研究设计与样本

  • 研究纳入22例患者37耳临床诊断耳海绵化症及22例对照患者35耳,行颞骨锥形束CT,于卵圆窗前区、外半规管骨岛及邻近含气腔设置ROI,计算卵圆窗前区归一化至正常耳囊骨和空气的相对衰减比。

关键影像表现/征象

  • 耳海绵化症组卵圆窗前区相对衰减比显著低于对照组(P < .001)。

诊断标准与关键数值

  • ROC分析最佳截断相对衰减比为0.876,诊断耳海绵化症准确率97.2%。

临床应用与阅片要点

  • 作者认为颞骨锥形束CT内校准像素值比值可客观辅助诊断活动性/海绵期窗型耳硬化症。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Quantitative bone densitometry on multidetector CT of the temporal bone is a diagnostic adjunct for otosclerosis in its active (spongiotic) phase, but translating this technique to conebeam CT is limited by the technical variability of conebeam CT pixel values. The purpose of this study was to evaluate the performance of internally calibrated conebeam CT pixel value measurements that can enable the determination of active fenestral otosclerosis (otospongiosis).

MATERIALS AND METHODS: This study included 37 ears in 22 patients with a clinical diagnosis of otospongiosis in those ears and 35 ears in 22 control patients without the diagnosis. Temporal bone conebeam CT was performed. ROIs were set anterior to the oval window, in the lateral semicircular canal bone island, and in a nearby aerated space. Mean conebeam CT pixel values in these regions determined the relative attenuation ratio of the area anterior to the oval window normalized to normal otic capsule bone and air.

RESULTS: The relative attenuation ratio for cases of otospongiosis was significantly lower than that for controls (P < .001). Based on receiver operating characteristic analysis, the optimal cutoff relative attenuation ratio was 0.876, which had an accuracy of 97.2% for the diagnosis of otospongiosis.

CONCLUSIONS: Internally calibrated pixel value ratios in temporal bone conebeam CT can feasibly help diagnose active/spongiotic-phase fenestral otosclerosis in an objective manner.