尸体头标本中镫骨的超高分辨率CT可视化:初步研究
本研究用超高分辨率CT与128层多排CT扫描30具尸体头标本共60耳,按3分Likert量表对镫骨头、前后脚、底板、砧镫关节及锥隆起内镫骨肌评分,并在超高分辨率CT上测量镫骨各径线。结果显示除镫骨头外,超高分辨率CT对各解剖结构的评分均显著高于多排CT(P<0.05),并给出镫骨总高度等线性数据。
要点
- 除镫骨头外,超高分辨率CT对镫骨各结构的显示评分均显著高于128层多排CT(P<0.05)。
- 超高分辨率CT观察者间一致性系数为0.65–0.86,评分一致性良好至优秀。
- 超高分辨率CT测得镫骨总高度3.48±0.33 mm,镫骨底板厚度0.22±0.06 mm。
核心结论
- 超高分辨率CT能勾勒镫骨细微结构并提供镫骨尺寸线性数据,可能有助于检出镫骨疾病并制定个体化手术方案。
研究设计与样本
- 初步研究,采用30具尸体人头的60耳,先后用超高分辨率CT与128层多排CT以临床参数扫描,以3分Likert量表对镫骨各结构评分并在超高分辨率CT上做线性测量。
关键影像表现/征象
- 对镫骨头、前后脚、底板、砧镫关节及锥隆起内镫骨肌按3分Likert量表评分。
- 除镫骨头外,超高分辨率CT对上述各解剖结构的定性评分均显著高于多排CT(P<0.05)。
诊断标准与关键数值
- 超高分辨率CT图像定性评分的观察者间一致性系数为0.65–0.86,属良好至优秀。
- 超高分辨率CT测得镫骨总高度3.48±0.33 mm。
- 闭孔高度1.77±0.28 mm、宽度2.19±0.33 mm。
- 前脚宽度0.20±0.06 mm、后脚宽度0.22±0.06 mm。
- 镫骨底板厚度0.22±0.06 mm,砧镫关节角度95.91±10.69°。
临床应用与阅片要点
- 作者认为超高分辨率CT提供的镫骨尺寸线性数据可能有助于检出镫骨疾病并制定个体化手术方案。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: This study aimed to assess stapes visualization using an ultra-high resolution computed tomography (U-HRCT).
METHOD: Sixty ears from 30 cadaveric human heads were scanned by both U-HRCT and 128-section multislice CT (MSCT) with clinical parameters. Image quality of the stapes head, anterior and posterior crura, footplate, incudostapedial joint and stapedial muscle within the pyramidal eminence was scored using a 3-point Likert scale. Linear measurements of the stapes configuration were performed on U-HRCT.
RESULTS: The interobserver agreement for image qualitative score on U-HRCT was good to excellent (interobserver agreement coefficients 0.65-0.86). With the exception of the stapes head, U-HRCT achieved significantly higher qualitative scores than MSCT across all anatomical structures (Ps < 0.05). The total height of the stapes was measured to be 3.48 ± 0.33 mm. The height and width of the obturator foramen were 1.77 ± 0.28 mm and 2.19 ± 0.33 mm, respectively. The widths of the anterior and posterior crura were 0.20 ± 0.06 mm and 0.22 ± 0.06 mm, respectively. The thickness of the footplate was 0.22 ± 0.06 mm, and the angle of the incudostapedial joint was 95.91 ± 10.69°.
CONCLUSIONS: U-HRCT is capable of delineating fine structures of the stapes and provides linear data on dimensions of the stapes, which could be helpful for detecting stapes disease and making individualized surgical plans in the clinical setting.
引用
- Tang R, Yin H, Wang Z, et al. Stapes visualization by ultra-high resolution CT in cadaveric heads: A preliminary study. Eur J Radiol. 2021. PMID: 34058698. doi:10.1016/j.ejrad.2021.109786
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。