成人胶质瘤的脑血流与肿瘤血流:磁共振成像结果的系统综述
该系统综述纳入2000至2019年间34项使用DSC-MRI、DCE-MRI或ASL测量成人幕上胶质瘤血流的MR研究,共1415例患者、1460次扫描。结果显示随胶质瘤级别升高(II级 vs IV级),肿瘤血流量增加(70.8 vs 145.5 ml/100 g/min,p<0.001),而脑血流量降低(85.3 vs 49.6 ml/100 g/min,p<0.001)。结论认为高级别胶质瘤的占位效应损害周围脑组织血流,且可随手术改善。
要点
- 随胶质瘤级别升高(II级 vs IV级),肿瘤血流量增加(70.8 vs 145.5 ml/100 g/min,p<0.001)而脑血流量降低(85.3 vs 49.6 ml/100 g/min,p<0.001)。
- IV级胶质瘤治疗后,同侧白质脑血流量较治疗前升高(24.9 ± 1.2 vs 26.1 ± 0.0 ml/100 g/min,p<0.001)。
- 高级别胶质瘤的占位效应似乎损害周围脑组织血流,且该损害可随治疗改善。
核心结论
- 高级别胶质瘤的占位效应似乎损害周围脑组织血流,且该损害可随治疗改善。
研究设计与样本
- 系统综述,检索MEDLINE、EMBASE和Cochrane数据库2000年1月1日至2019年12月31日,纳入34项研究、1415例患者、1460次扫描,使用DSC-MRI、DCE-MRI或ASL测量成人幕上胶质瘤血流。
关键影像表现/征象
- 随胶质瘤级别升高(II级 vs IV级),肿瘤血流量增加(70.8 vs 145.5 ml/100 g/min,p<0.001)。
- 随胶质瘤级别升高(II级 vs IV级),脑血流量降低(85.3 vs 49.6 ml/100 g/min,p<0.001)。
- IV级胶质瘤治疗后,同侧白质脑血流量较治疗前升高(24.9 ± 1.2 vs 26.1 ± 0.0 ml/100 g/min,p<0.001),对侧白质脑血流量亦较治疗前升高(25.6 ± 0.2 vs 26.0 ± 0.0 ml/100 g/min,p<0.001)。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Blood flow is the rate of blood movement and relevant to numerous processes, though understudied in gliomas. The aim of this review was to pool blood flow metrics obtained from MRI modalities in adult supratentorial gliomas.
METHODS: MEDLINE, EMBASE and the Cochrane database were queried 01/01/2000-31/12/2019. Studies measuring blood flow in adult Grade II-IV supratentorial gliomas using dynamic susceptibility contrast (DSC) MRI, dynamic contrast enhanced MRI (DCE-MRI) or arterial spin labelling (ASL) were included. Absolute and relative cerebral blood flow (CBF), peritumoral blood flow and tumoral blood flow (TBF) were reported.
RESULTS: 34 studies were included with 1415 patients and 1460 scans. The mean age was 52.4 ± 7.3 years. Most patients had glioblastoma (n = 880, 64.6%). The most common imaging modality was ASL (n = 765, 52.4%) followed by DSC (n = 538, 36.8%). Most studies were performed pre-operatively (n = 1268, 86.8%). With increasing glioma grade (II vs IV), TBF increased (70.8 vs 145.5 ml/100 g/min, p < 0.001) and CBF decreased (85.3 vs 49.6 ml/100 g/min, p < 0.001). In Grade IV gliomas, following treatment, CBF increased in ipsilateral (24.9 ± 1.2 vs 26.1 ± 0.0 ml/100 g/min, p < 0.001) and contralateral white matter (25.6 ± 0.2 vs 26.0± 0.0 ml/100 g/min, p < 0.001).
CONCLUSION: Our findings demonstrate that increased mass effect from high-grade gliomas impairs blood flow within the surrounding brain that can improve with surgery.
ADVANCES IN KNOWLEDGE: This systematic review demonstrates how mass effect from brain tumours impairs blood flow in the surrounding brain parenchyma that can improve with treatment.
引用
- Waqar M, Lewis D, Agushi E, et al. Cerebral and tumoral blood flow in adult gliomas: a systematic review of results from magnetic resonance imaging. Br J Radiol. 2021. PMID: 34106749. doi:10.1259/bjr.20201450
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。