文献速递神经介入DSA

Woven EndoBridge装置治疗破裂颅内动脉瘤的安全性与有效性:系统综述与Meta分析

Safety and Efficacy of the Woven EndoBridge Device for Treatment of Ruptured Intracranial Aneurysms: A Systematic Review and Meta-analysis.
PubMed 文献 · AJNR Am J Neuroradiol · 2021-06-11

该系统综述与Meta分析纳入18项研究共487例患者496个破裂动脉瘤,评估Woven EndoBridge装置的安全性与有效性。结果显示晚期再出血率1.1%,治疗相关围手术期并发症率13.2%,总体临床并发症率3.2%,良好临床结局85%, adequate闭塞率87.3%,再治疗率5.1%。作者认为该装置在破裂动脉瘤管理中安全有效,但需进一步研究。

要点

  • Woven EndoBridge治疗破裂动脉瘤的 adequate 闭塞率为87.3%(95%CI 82.1%-92.4%)。
  • 晚期再出血率1.1%(95%CI 0.1%-2.1%),再治疗率5.1%(95%CI 3%-7.3%)。
  • 治疗相关围手术期并发症率13.2%,总体临床并发症率3.2%。

核心结论

  • 该Meta分析显示Woven EndoBridge装置在破裂动脉瘤管理中安全有效,但需进一步研究。

研究设计与样本

  • 系统综述与Meta分析,检索Ovid Evidence-Based Medicine Reviews、EMBASE、MEDLINE、Scopus和Web of Science Core Collection从建库至2020年的所有研究,纳入18项研究共487例患者496个破裂动脉瘤,采用随机效应模型进行Meta分析。

诊断标准与关键数值

  • 晚期再出血率1.1%(95%CI 0.1%-2.1%);治疗相关围手术期并发症率13.2%(95%CI 9.2%-17.2%);总体临床并发症率3.2%(95%CI 1.6%-4.7%);出血性并发症13例(2%;95%CI 0.8%-3.3%);血栓栓塞性并发症41例(6.8%;95%CI 4.6%-9%);良好临床结局85%;手术相关死亡率2.1%(95%CI 0.8%-3.3%);总体死亡率11.5%(95%CI 7%-16%);末次随访时adequate闭塞率87.3%(95%CI 82.1%-92.4%);再治疗率5.1%(95%CI 3%-7.3%)。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 该Meta分析受选择偏倚和高异质性限制。
  • 结论指出需进一步研究。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: The Woven EndoBridge device has been increasingly used to treat wide-neck aneurysms, particularly ruptured ones.

PURPOSE: Our aim was to investigate the safety and efficacy of the Woven EndoBridge device in the treatment of ruptured intracranial aneurysms.

DATA SOURCES: All studies evaluating the outcomes of Woven EndoBridge device use in the treatment of ruptured intracranial aneurysms from inception through 2020 were searched on Ovid Evidence-Based Medicine Reviews, EMBASE, MEDLINE, Scopus, and the Web of Science Core Collection.

STUDY SELECTION: Eighteen studies encompassing 487 patients with 496 ruptured aneurysms treated with the Woven EndoBridge device were included.

DATA ANALYSIS: We studied rates of rerupture and retreatment, angiographic outcomes at the last follow-up point, complications, and mortality rates. Data were collected on anticoagulation and antiplatelet use. Meta-analysis was performed using the random effects model.

DATA SYNTHESIS: The rate of late rebleeding was 1.1% (95% CI, 0.1%-2.1%). The treatment-related perioperative complication rate and the overall clinical complication rate were 13.2% (95% CI, 9.2%-17.2%) and 3.2% (95% CI, 1.6%-4.7%), respectively. Thirteen hemorrhagic (2%; 95% CI, 0.8%-3.3%) and 41 thromboembolic (6.8%; 95% CI, 4.6%-9%) complications occurred. Favorable clinical outcomes were achieved in 85% of patients. Procedure-related mortality and overall mortality rates were 2.1% (95% CI, 0.8%-3.3%) and 11.5% (95% CI, 7%-16%), respectively. At last follow-up, an adequate occlusion rate was 87.3% (95% CI, 82.1%-92.4%) and the retreatment rate was 5.1% (95% CI, 3%-7.3%).

LIMITATIONS: Our meta-analysis is limited by selection bias and high heterogeneity.

CONCLUSIONS: This meta-analysis demonstrated the safety and efficacy of the Woven EndoBridge device in the management of ruptured aneurysms, but further studies are needed.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。