文献速递神经CT

使用单次检测器在平扫CT上自动检测脑转移瘤

Automated detection of brain metastases on non-enhanced CT using single-shot detectors.
PubMed 文献 · Neuroradiology · 2021-06-10

本研究纳入116例患者的116份平扫CT,用89例训练、27例测试单次检测器(SSD)模型,参考增强CT标注。SSD对≥6 mm病灶敏感度35.4%,总体敏感度23.8%、阳性预测值19.1%,每扫描假阳性率15.4;SSD漏检病灶中95%放射科医生亦未检出,SSD检出病灶中24%放射科医生回顾性未识别。

要点

  • SSD对≥6 mm脑转移瘤敏感度35.4%,总体敏感度23.8%,阳性预测值19.1%。
  • SSD每扫描假阳性率约15,阅片时需警惕假阳性。
  • SSD漏检病灶中95%放射科医生亦未检出。

核心结论

  • 所开发的SSD模型可在一定程度上检出大于6 mm的脑转移瘤,其中约四分之一连放射科医生回顾性亦无法识别。

研究设计与样本

  • 研究纳入116例患者的116份平扫CT,以89例训练、27例测试SSD模型,由三名放射科医生在增强CT上以边界框标注,平扫CT配准并重采样至增强CT。

关键影像表现/征象

  • 平扫CT上脑转移瘤的密度、坏死和大小影响放射科医生的可见性。
  • 周围水肿可增强SSD的检测性能。

诊断标准与关键数值

  • 在SSD 50%置信度阈值下评估检测性能。
  • ≥6 mm病灶:敏感度35.4%(95%CI [32.3%, 33.5%];51/144),每扫描假阳性率14.9(95%CI [12.4, 13.9])。
  • 总体:敏感度23.8%(95%CI [21.3%, 22.8%];55/231),阳性预测值19.1%(95%CI [18.5%, 20.4%];98/513),每扫描假阳性率15.4(95%CI [12.9, 14.5])。
  • SSD漏检病灶中95%(168/176)放射科医生亦未检出。
  • SSD检出病灶中24%(13/50)放射科医生回顾性未识别。

临床应用与阅片要点

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To develop and investigate deep learning-based detectors for brain metastases detection on non-enhanced (NE) CT.

METHODS: The study included 116 NECTs from 116 patients (81 men, age 66.5 ± 10.6 years) to train and test single-shot detector (SSD) models using 89 and 27 cases, respectively. The annotation was performed by three radiologists using bounding-boxes defined on contrast-enhanced CT (CECT) images. NECTs were coregistered and resliced to CECTs. The detection performance was evaluated at the SSD's 50% confidence threshold using sensitivity, positive-predictive value (PPV), and the false-positive rate per scan (FPR). For false negatives and true positives, binary logistic regression was used to examine the possible contributing factors.

RESULTS: For lesions 6 mm or larger, the SSD achieved a sensitivity of 35.4% (95% confidence interval (CI): [32.3%, 33.5%]); 51/144) with an FPR of 14.9 (95% CI [12.4, 13.9]). The overall sensitivity was 23.8% (95% CI: [21.3%, 22.8%]; 55/231) and PPV was 19.1% (95% CI: [18.5%, 20.4%]; 98/ of 513), with an FPR of 15.4 (95% CI [12.9, 14.5]). Ninety-five percent of the lesions that SSD failed to detect were also undetectable to radiologists (168/176). Twenty-four percent of the lesions (13/50) detected by the SSD were undetectable to radiologists. Logistic regression analysis indicated that density, necrosis, and size contributed to the lesions' visibility for radiologists, while for the SSD, the surrounding edema also enhanced the detection performance.

CONCLUSION: The SSD model we developed could detect brain metastases larger than 6 mm to some extent, a quarter of which were even retrospectively unrecognizable to radiologists.

来源:Neuroradiology,查看原文。版权归原作者所有。

引用

  1. Kato S, Amemiya S, Takao H, et al. Automated detection of brain metastases on non-enhanced CT using single-shot detectors. Neuroradiology. 2021. PMID: 34114064. doi:10.1007/s00234-021-02743-6

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。