文献速递神经外周血管MRDSA

静音磁共振血管成像在颅内硬脑膜动静脉瘘评估与特征描述中的应用价值

Utility of silent magnetic resonance angiography in the evaluation and characterisation of intracranial dural arteriovenous fistula.
PubMed 文献 · Clin Radiol · 2021-06-16

前瞻性纳入20例硬脑膜动静脉瘘患者,评估静音MRA在诊断、分型及治疗规划中的价值,并与DSA对照。静音MRA对瘘口位置和分型的敏感度及准确率均为100%,对全部供血动脉和引流静脉的敏感度分别为82%和76.5%,治疗决策与DSA完全一致。

要点

  • 静音MRA对硬脑膜动静脉瘘的位置和Borden/Cognard分型诊断敏感度及准确率均为100%。
  • 静音MRA对全部供血动脉和引流静脉的敏感度分别为82%和76.5%,突出供血动脉和即刻引流静脉的敏感度提高至90%和94%。
  • 静音MRA在94%病例中准确识别潜在可及供血动脉,治疗决策与DSA全部一致。

核心结论

  • 静音MRA是一种有前景的MR技术,可提供与DSA相似的诊断和治疗信息。

研究设计与样本

  • 前瞻性纳入20例连续硬脑膜动静脉瘘患者,作为常规检查的一部分行静音MRA和DSA检查,分析瘘口诊断与位置、Borden和Cognard分型、全部供血动脉及静脉引流,并制定治疗策略、预测可及路径和血管,经血管内治疗证实。

关键影像表现/征象

  • 静音MRA对瘘口位置和分型的敏感度及准确率均为100%。
  • 静音MRA对全部供血动脉的敏感度为82%,对全部引流静脉的敏感度为76.5%。
  • 考虑突出供血动脉时,静音MRA对供血动脉的敏感度提高至90%;考虑即刻静脉引流时,对引流静脉的敏感度提高至94%。
  • 漏诊静脉的原因包括血栓性静脉窦、静脉窦血流缓慢、小口径血管和图像质量下降。

诊断标准与关键数值

  • 以DSA为参考标准,静音MRA对瘘口位置和Borden/Cognard分型的敏感度及准确率均为100%。
  • 静音MRA对全部供血动脉的敏感度为82%,对全部引流静脉的敏感度为76.5%。
  • 静音MRA对突出供血动脉的敏感度为90%,对即刻引流静脉的敏感度为94%。
  • 静音MRA在94%病例中准确识别潜在可及供血动脉,治疗决策与DSA全部一致。

临床应用与阅片要点

  • 静音MRA可用于硬脑膜动静脉瘘的诊断、分型和治疗规划,提供与DSA相似的信息。
  • 判读时需注意血栓性静脉窦、静脉窦血流缓慢、小口径血管和图像质量下降可能导致引流静脉漏诊。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To evaluate the utility of silent magnetic resonance angiography (MRA) in the diagnosis, characterisation, and therapeutic planning of intracranial dural arteriovenous fistula (DAVF).

MATERIALS AND METHODS: Twenty consecutive patients with DAVF were enrolled prospectively and were evaluated using silent MRA and digital subtraction angiography (DSA) as a part of routine work-up. The diagnosis and location of fistula, Borden and Cognard classification, entire arterial feeders, and venous drainage were analysed. A therapeutic strategy was formulated, and the accessible route and vessel were predicted, which was confirmed on endovascular treatment.

RESULTS: Silent MRA was 100% sensitive and accurate for location and classification of fistulas. Silent MRA showed a sensitivity of 82% and 76.5% for entire arterial feeders and draining veins, which improved to a sensitivity of 90% and 94% when prominent feeders and immediate venous drainage was considered. Among the missed veins, thrombosed sinus, slow sinus flow, small calibre, reduced image quality were the causes. The therapeutic decision matched with DSA in all cases and silent MRA accurately identified the potential accessible feeder in 94% cases.

CONCLUSION: Silent MRA is a promising MR technique that can provide both diagnostic and therapeutic information similar to that obtained from DSA.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Balasubramanian AP, Kannath SK, Rajan JE, et al. Utility of silent magnetic resonance angiography in the evaluation and characterisation of intracranial dural arteriovenous fistula. Clin Radiol. 2021. PMID: 34144807. doi:10.1016/j.crad.2021.05.008

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。