7T BioSpec MRI扫描仪上C6胶质瘤的高分辨率扩散加权成像:肿瘤细胞密度和核质比与表观扩散系数的相关性
研究在7T BioSpec MRI上对11只C6胶质瘤大鼠模型行高分辨率扩散加权成像,分析33个层面的ADC值与GFAP免疫染色所测肿瘤细胞密度及核质比的相关性。结果显示最小ADC与细胞密度和核质比均呈显著负相关,提示其可能作为反映这两种病理特征的生物标志物。
要点
- 最小ADC与肿瘤细胞密度相关系数为-0.712(p<0.001),与核质比相关系数为-0.565(p=0.001)。
- 平均ADC与细胞密度相关系数为-0.631(p<0.001),与核质比相关系数为-0.426(p=0.013)。
- 最大ADC仅与细胞密度相关(r=-0.460,p=0.007),与核质比无显著相关。
核心结论
- C6胶质瘤中最小ADC与细胞密度和核质比均呈良好负相关,可能作为反映这两种病理特征的生物标志物。
研究设计与样本
- 动物实验:11只携带C6胶质瘤的大鼠模型,行T1 RARE、T2 RARE和高分辨率扩散加权成像,共分析33个连续层面,以GFAP免疫染色切片与ADC测量配准计算肿瘤细胞密度和核质比。
关键影像表现/征象
- 最小、平均和最大ADC的中位值分别为0.443×10⁻³、0.744×10⁻³和1.140×10⁻³ mm²/s。
- 肿瘤细胞密度中位值为2151.234/0.025 mm²,核质比中位值为0.857。
- 每个模型取三个连续层面绘制感兴趣区测量ADC,中间层面定位于实性肿瘤面积最大的平面。
诊断标准与关键数值
- 最小ADC与细胞密度呈显著负相关,相关系数-0.712(p<0.001)。
- 平均ADC与细胞密度呈显著负相关,相关系数-0.631(p<0.001)。
- 最大ADC与细胞密度呈显著负相关,相关系数-0.460(p=0.007)。
- 最小ADC与核质比呈显著负相关,相关系数-0.565(p=0.001)。
- 平均ADC与核质比呈显著负相关,相关系数-0.426(p=0.013)。
临床应用与阅片要点
- 作者认为最小ADC可能作为反映C6胶质瘤细胞密度和核质比的生物标志物。
- 原文未据此给出临床阅片或报告的具体推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
RATIONALE AND OBJECTIVES: To determine the association of the apparent diffusion coefficient (ADC) with quantitative cellularity and the nuclear-to-cytoplasmic ratio in C6 glioma.
MATERIALS AND METHODS: Animal models bearing C6 gliomas underwent MR scans with T1 rapid acquisition with relaxation enhancement (RARE), T2 RARE, and high-resolution diffusion-weighted imaging sequences. For each model, three consecutive sections were used to draw regions of interest (ROIs) and measure ADC values; the middle section was localized in the plane with the maximal solid tumor area. The minimal, mean, and maximal ADC values were recorded for each ROI. GFAP-immunostained sections coregistered with ADC measurements were used to calculate tumor cellularity and the nuclear-to-cytoplasmic (N/C) ratio. Spearman's correlation was used to assess the relationship between ADC values and quantitative tumor cellularity as well as N/C ratios with a significance level of p < 0.05.
RESULTS: Thirty-three sections from 11 glioma-bearing rats were analyzed. The median values of the minimal, mean, and maximal ADC were 0.443 × 10-3, 0.744 × 10-3, and 1.140 × 10-3 mm2/s, respectively. The median cellularity and N/C ratio were 2151.234 per 0.025 mm2 and 0.857, respectively. The minimal, mean, and maximal ADCs were all significantly associated with cellularity, with correlation coefficients of -0.712 (p < 0.001), -0.631 (p < 0.001), and -0.460 (p = 0.007), respectively. The minimal and mean ADC had significant negative relationships with the N/C ratio, with correlation coefficients of -0.565 (p = 0.001) and -0.426 (p = 0.013), respectively.
CONCLUSION: The minimal ADC correlated well with cellularity and N/C ratios in C6 glioma and may be used as a biomarker of these two pathological features.
引用
- Haopeng P, Xuefei D, Zengai C, et al. High-Resolution Diffusion-Weighted Imaging of C6 Glioma on a 7T BioSpec MRI Scanner: Correlation of Tumor Cellularity and Nuclear-to-Cytoplasmic Ratio with Apparent Diffusion Coefficient. Acad Radiol. 2021. PMID: 34148856. doi:10.1016/j.acra.2021.02.009
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。