图像引导经皮空芯针活检对腹膜/大网膜病变诊断率的影响因素分析
回顾性分析单中心2010年4月至2020年3月连续297例患者共311个腹膜/大网膜病变行经皮空芯针活检的资料,技术成功率100%,诊断率93.9%,仅1.6%的操作为轻微并发症。脂肪为主型病变诊断率低于其他病变(82.6% vs 95.8%,p=0.002),诊断成功组病变前后径大于未诊断组(27.3±13.0 vs 20.7±8.4 mm,p=0.037)。
要点
- 腹膜/大网膜病变经皮空芯针活检诊断率达93.9%,技术成功率100%,轻微并发症仅1.6%。
- 脂肪为主型病变诊断率较低(82.6% vs 95.8%,p=0.002),阅片选靶时需注意。
- 前后径较大的病变更易获得诊断标本(27.3±13.0 vs 20.7±8.4 mm,p=0.037)。
核心结论
- 经皮空芯针活检对腹膜/大网膜病变诊断率高且不良事件少;前后径更大、CT密度更高的病变更可能获得有诊断价值的标本。
研究设计与样本
- 单中心回顾性研究,连续纳入297例患者(男67例、女230例;中位年龄64岁,范围15-87岁)共311个腹膜/大网膜病变,2010年4月至2020年3月行经皮空芯针活检;以手术或临床诊断结合随访为参考标准;不良事件按介入放射学会指南评估。
诊断标准与关键数值
- 诊断率93.9%、敏感度93.8%、特异度100%、阳性预测值100%、阴性预测值20.8%;靶病变中位前后径24 mm(范围5-78)、中位CT值46 HU(范围-75至140);穿刺路径上有腹水者106例(34.1%)。
临床应用与阅片要点
- 术前CT评估病变前后径及密度有助于预判取材成功率;脂肪为主型病变诊断率较低(82.6% vs 95.8%,p=0.002),可能需更注意取材;腹水位于穿刺路径上者106例(34.1%)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To evaluate the diagnostic yield, safety, and factors associated with the diagnostic yield of percutaneous core needle biopsy (PNB) for peritoneal/omental lesions.
METHODS: Consecutive 297 patients (67 men, 230 women; median age, 64 years [range 15-87]) who underwent a PNB for 311 peritoneal/omental lesions at a single center from April 2010 to March 2020 were evaluated retrospectively. The preprocedural CT findings, diagnostic yield, sensitivity, specificity, PPV, NPV, technical success rate, and adverse events were analyzed. Surgical or clinical diagnosis with follow-up was the diagnostic reference standard. Adverse events were evaluated using the Society of Interventional Radiology guidelines.
RESULTS: The median anteroposterior (AP) diameter and CT value of the target lesion were 24 mm (range 5-78) and 46 HU (range - 75 to 140), respectively. Ascites was interposed on the puncture route in 106 patients (34.1%). The technical success rate was 100%. The diagnostic yield, sensitivity, specificity, PPV, and NPV were 93.9%, 93.8%, 100%, 100%, and 20.8%, respectively. Minor complications were observed following five procedures (1.6%). The diagnostic yield was lower for fat-dominant lesions than for other lesions (82.6% vs. 95.8%, p = 0.002). The diagnostic PNB group had a greater AP diameter than did the non-diagnostic PNB group (27.3 ± 13.0 vs. 20.7 ± 8.4 mm, p = 0.037).
CONCLUSION: PNB for peritoneal/omental lesions provided a sufficiently high diagnostic yield and minimal adverse events. Lesions with a greater AP diameter and a higher density on CT would provide more diagnostic specimens from this technique.
引用
- Sugawara S, Sone M, Itou C, et al. Analysis of factors affecting the diagnostic yield of image-guided percutaneous core needle biopsy for peritoneal/omental lesions. Abdom Radiol (NY). 2021. PMID: 34047802. doi:10.1007/s00261-021-03088-7
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。