文献速递介入外周血管DSA

介入放射学前瞻性不良事件报告系统的评估

Evaluation of a prospective adverse event reporting system in interventional radiology.
PubMed 文献 · Clin Radiol · 2021-05-26

本研究在单中心对471例连续动脉手术评估前瞻性不良事件报告系统(DLAE)的性能,以回顾性病历审查为参考标准。参考标准认定38例(8%)发生不良事件,DLAE仅识别20/38(53%),敏感度52.6%、特异度100%、准确率96%。结论认为无临床整合的前瞻性不良事件报告系统不能检出所有手术并发症,整合临床随访可改善报告性能(p=0.0015)。

要点

  • 参考标准认定8%(38/471)动脉手术发生不良事件,DLAE仅报告其中53%(20/38)。
  • DLAE敏感度52.6%(95%CI 36-69%),特异度100%(95%CI 99-100%),准确率96%(95%CI 94-97%)。
  • 整合临床随访可改善不良事件报告系统性能(p=0.0015),无临床整合的系统不能检出所有并发症。

核心结论

  • 无临床整合的前瞻性不良事件报告系统不能检出所有手术并发症。

研究设计与样本

  • 观察性队列研究,单中心,471例连续动脉手术(465例患者,中位年龄65岁,四分位距54-77,男276例),由4名介入放射科医生在2年内完成,以回顾性病历审查为参考标准。

诊断标准与关键数值

  • DLAE识别20/38(53%)不良事件,K=0.67(95%CI 0.53-0.81,p=0.0001),敏感度52.6%(95%CI 36-69%),特异度100%(95%CI 99-100%),阳性预测值100%,阴性预测值96%(95%CI 94.5-97%),准确率96%(95%CI 94-97%)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To assess the performance of a prospective adverse event (AE) reporting system.

MATERIALS AND METHODS: Four hundred and seventy-one consecutive arterial procedures were performed in 465 patients (median age, 65 years; interquartile range, 54-77; 276 men) over 2 years by four interventional radiologists at a single centre where clinical follow-up was not performed routinely by interventional radiology (IR). AEs were reported prospectively using a radiology information system or in interventional radiologists' electronic records and combined in a departmental listing of adverse events (DLAE). A retrospective medical record review was performed to identify a reference standard list of AEs for this observational cohort study. AEs were graded according to the Society of Interventional Radiology AE classification system. Descriptive statistics were calculated for the performance of the DLAE. A model comparing the rate of reporting of AEs with and without integration of clinical follow-up was tested for significance.

RESULTS: Thirty-eight of the 471 (8%) IR procedures had an AE according to the reference standard. The DLAE identified 20/38 (53%) of AEs (K=0.67 [good agreement], 95% confidence interval [CI] agreement=0.53-0.81; p=0.0001; sensitivity 52.6% [95% CI, 36-69%], specificity 100% [95% CI, 99-100%], positive predictive value [PPV] 100%, negative predictive value [NPV] 96 [95% CI, 94.5-97%], accuracy 96% [95% CI, 94-97%]). The performance of the AE reporting system will improve with integration of clinical follow-up (p=0.0015).

CONCLUSION: A prospective AE reporting system without clinical integration will not detect all procedure complications.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Mulvihill SB, Healy GM, O'Rourke C, et al. Evaluation of a prospective adverse event reporting system in interventional radiology. Clin Radiol. 2021. PMID: 34052009. doi:10.1016/j.crad.2021.04.009

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。