文献速递骨肌MR

腰椎MRI中T2加权Dixon脂肪图像能否替代T1加权图像用于伴Modic改变的退行性椎间盘疾病

Can T2-weighted Dixon fat-only images replace T1-weighted images in degenerative disc disease with Modic changes on lumbar spine MRI?
PubMed 文献 · Eur Radiol · 2021-05-15

本研究回顾性纳入114例因下腰痛行腰椎MRI且至少一个椎体水平存在Modic改变的患者,以包含矢状位T1加权序列和T2加权Dixon水图像的标准化方案为参考标准,评估仅含矢状位T2加权Dixon脂肪和水图像的替代方案的诊断效能和观察者间一致性。替代方案检测任何Modic改变的敏感度为100.00%(95%CI 99.03-100.00)、特异度为98.89%(95%CI 98.02-99.44),各Modic亚型和结构变量的诊断效能良好,观察者间一致性为中等至极好(kappa 0.51-0.92)。结论认为联合T2加权Dixon水图像时,T2加权Dixon脂肪图像相比T1加权序列提供良好诊断效能,可缩短方案。

要点

  • 替代方案(仅T2 Dixon脂肪和水图像)检测任何Modic改变的敏感度100.00%、特异度98.89%。
  • 观察者间一致性kappa 0.51-0.92,除小关节病变外各变量一致性为中等至极好。
  • 联合T2 Dixon水图像时,T2 Dixon脂肪图像诊断效能良好,可缩短腰椎MRI方案。

核心结论

  • 联合T2加权Dixon水图像时,T2加权Dixon脂肪图像在伴Modic改变的腰椎退行性椎间盘疾病中相比T1加权序列提供良好诊断效能,因此可能允许缩短方案。

研究设计与样本

  • 回顾性研究,纳入2017年2月至2019年3月因下腰痛行腰椎MRI的114例患者,所有MRI至少一个椎体水平显示Modic改变;以包含矢状位T1加权序列和T2加权Dixon水图像的标准化方案为参考标准,评估仅含矢状位T2加权Dixon脂肪和水图像的替代方案;两名放射科医生先读标准化方案,1个月后读替代方案。

诊断标准与关键数值

  • 替代方案检测任何Modic改变:敏感度100.00%(95%CI 99.03-100.00),特异度98.89%(95%CI 98.02-99.44);检测各Modic亚型:敏感度100%,特异度97.62-100%;检测结构变量:敏感度88.43-99.75%,特异度99.58-99.91%;观察者间一致性kappa 0.51-0.92。

临床应用与阅片要点

  • 作者认为,联合T2加权Dixon水图像时,T2加权Dixon脂肪图像相比T1加权序列提供良好诊断效能,可因此允许缩短方案;要点提出在此临床情况下可提出包含T2加权Dixon序列而不含T1加权序列的缩短MRI方案。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To evaluate the diagnostic performance and interobserver agreement of a magnetic resonance imaging (MRI) protocol that only includes sagittal T2-weighted Dixon fat and water images as an alternative to a standard protocol that includes both sagittal T1-weighted sequence and T2-weighted Dixon water images as reference standard in lumbar degenerative disc disease with Modic changes.

METHODS: From February 2017 to March 2019, 114 patients who underwent lumbar spine MRI for low back pain were included in this retrospective study. All MRI showed Modic changes at least at one vertebral level. Two radiologists read the standard protocol and 1 month later the alternative protocol. All MRI were assessed for Modic changes (types, location, extension) as well as structural changes (endplate defects, facet arthropathy, spinal stenosis, foraminal stenosis, Schmorl nodes, spondylolisthesis, disc bulges, and degeneration). Interobserver agreement was assessed, as well as diagnostic performance using the standard protocol as reference standard.

RESULTS: Interobserver agreement was moderate to excellent (kappa ranging from 0.51 to 0.92). Diagnostic performance of the alternative protocol was good for detection of any Modic change (sensitivity = 100.00% [95% CI, 99.03-100.00]; specificity = 98.89% [95% CI, 98.02-99.44]), as well as for detection of each Modic subtype and structural variables (sensitivity respectively 100% and ranging from 88.43 to 99.75% ; specificity ranging respectively from 97.62 to 100% and 99.58 to 99.91% ).

CONCLUSIONS: Combined with T2-weighted Dixon water images, T2-weighted Dixon fat images provide good diagnostic performance compared to T1-weighted images in lumbar degenerative disc disease with Modic changes, and could therefore allow for a shortened protocol.

KEY POINTS: • Combined with T2-weighted Dixon water images, T2-weighted Dixon fat images (in comparison to T1-weighted sequence) can provide good diagnostic performance in lumbar degenerative disc disease with Modic changes. • Interobserver agreement of the alternative protocol including sagittal T2-weighted Dixon fat and water images was substantial to excellent for every studied variable except for facet arthropathy. • A shortened MRI protocol including T2-weighted Dixon sequence without T1-weighted sequence could be proposed in this clinical setting.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Yang S, Lassalle L, Mekki A, et al. Can T2-weighted Dixon fat-only images replace T1-weighted images in degenerative disc disease with Modic changes on lumbar spine MRI? Eur Radiol. 2021. PMID: 33993328. doi:10.1007/s00330-021-07946-2

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。