文献速递骨肌介入DR

透视引导下髋关节穿刺对假体周围关节感染的诊断价值

Diagnostic value of fluoroscopy-guided hip aspiration for periprosthetic joint infection.
PubMed 文献 · Skeletal Radiol · 2021-05-06

回顾性分析202例髋关节置换术后疼痛患者,以2018年MSIS标准为参考,评估透视引导下髋关节穿刺诊断假体周围关节感染(PJI)的价值。穿刺(AUC=0.78)和术中参数(0.80)优于血清学(0.64)和临床参数(0.68);培养敏感度64.0%、准确率78.5%,滑液多形核中性粒细胞百分比(PMN%)敏感度74.2%、准确率82.1%。排除使用抗生素患者后敏感度显著提高,但穿刺阴性不能排除PJI。

要点

  • 穿刺培养诊断PJI的敏感度为64.0%,准确率为78.5%。
  • 滑液PMN%诊断PJI的敏感度为74.2%,准确率为82.1%。
  • 穿刺阴性不能排除PJI,穿刺是治疗规划的重要检查。

核心结论

  • 术前髋关节穿刺在诊断PJI方面表现出良好的诊断性能,但穿刺阴性结果不能排除PJI;作者认为穿刺是髋关节置换术后疼痛患者治疗规划的必要检查。

研究设计与样本

  • 回顾性研究,纳入2014年1月至2018年12月间因髋关节置换术后疼痛行透视引导下髋关节穿刺并后续接受翻修手术的患者202例(其中感染髋91例),以2018年MSIS标准为参考标准。

诊断标准与关键数值

  • 以2018年MSIS标准为参考,穿刺培养诊断PJI的敏感度为64.0%,准确率为78.5%。
  • 以2018年MSIS标准为参考,滑液PMN%诊断PJI的敏感度为74.2%,准确率为82.1%。
  • 穿刺参数诊断PJI的AUC为0.78,术中参数AUC为0.80,血清学参数AUC为0.64,临床参数AUC为0.68。

临床应用与阅片要点

  • 穿刺前至少停用抗生素2周。
  • 穿刺培养和滑液PMN%均可用于评估PJI,但穿刺阴性不能排除PJI。
  • 作者认为,髋关节穿刺是髋关节置换术后疼痛患者治疗规划的必要检查。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To assess the value of preoperative joint aspiration in detecting periprosthetic joint infection (PJI) in patients undergoing revision hip arthroplasty and to compare these with the clinical findings, serum markers, and intraoperative findings.

MATERIALS AND METHODS: Fluoroscopically guided hip aspirations in patients with pain after hip arthroplasty were retrospectively reviewed from January 2014 to December 2018. All hips underwent subsequent revision hip arthroplasty. Antibiotics were discontinued at least 2 weeks before the aspiration. The 2018 Musculoskeletal Infection Society (MSIS) criteria served as a standard of reference for PJI. Clinical, serum, synovial, and intraoperative parameters were recorded in all patients. Correlations between all parameters with PJI diagnosis were analyzed using linear and logistic regression models with ROC analysis.

RESULTS: In 202 hips that included 91 septic hips, hip aspiration (AUC = 0.78) and intraoperative (0.80) parameters performed better than serum-based tests (0.64) and clinical parameters (0.68) in detecting PJI. Using MSIS criteria as a standard of reference, hip aspiration had a sensitivity of 64.0% and an accuracy of 78.5% for cultures and a sensitivity of 74.2% and an accuracy of 82.1% for synovial polymorphonuclear neutrophils% (PMN%). Results substantially improved sensitivity after excluding patients that were treated with antibiotics, particularly culture results.

CONCLUSIONS: Preoperative hip aspiration showed good diagnostic performance in diagnosing PJI compared with MSIS criteria as a standard of reference. But a negative result from aspirate could not rule out PJI. Based on our findings, hip aspiration is an essential test for treatment planning in patients with pain after hip arthroplasty.

来源:Skeletal Radiol,查看原文。版权归原作者所有。

引用

  1. Kanthawang T, Bodden J, Joseph GB, et al. Diagnostic value of fluoroscopy-guided hip aspiration for periprosthetic joint infection. Skeletal Radiol. 2021. PMID: 33956170. doi:10.1007/s00256-021-03795-8

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。