文献速递骨肌儿科影像技术与安全US

耻骨软骨与耻骨后脂肪垫测量优化婴儿发育性髋关节发育不良的通用超声筛查:1896 例髋关节数据

Pulvinar and pubic cartilage measurements to refine universal ultrasound screening for developmental dysplasia of the hip: Data from 1896 infant hips.
PubMed 文献 · Eur J Radiol · 2021-04-22

单中心观察性前瞻性研究纳入 948 例婴儿共 1896 例髋关节,在通用超声筛查中测量耻骨股骨距离(PFD)、耻骨软骨厚度及耻骨后脂肪垫厚度,得出耻骨软骨厚度均值 1.25 mm±0.58 mm、上限阈值 2.39 mm,耻骨后脂肪垫厚度均值 2.67 mm±0.78 mm、上限阈值 4.20 mm,耻骨软骨测量观察者间重复性高;作者认为系统测量可识别假阳性,PFD 增宽由耻骨软骨 >2.39 mm 且不伴耻骨后脂肪垫增大(<4.20 mm)所致者可仅随访而不过度治疗。

要点

  • 耻骨软骨厚度均值 1.25 mm±0.58 mm,上限阈值 2.39 mm(+1.96σ)。
  • 耻骨后脂肪垫厚度均值 2.67 mm±0.78 mm,上限阈值 4.20 mm(+1.96σ)。
  • PFD 增宽若源于耻骨软骨 >2.39 mm 且耻骨后脂肪垫 <4.20 mm,可仅随访而不过度治疗。

核心结论

  • 系统测量耻骨软骨与耻骨后脂肪垫可能通过识别假阳性来优化治疗决策。

研究设计与样本

  • 单中心观察性前瞻性研究,2016 年 12 月至 2018 年 1 月,948 例婴儿共 1896 例髋关节,纳入标准为超声检查时矫正年龄 4 至 12 周,采用 Couture 与 Tréguier 方法测量 PFD,并在同一超声切面测量耻骨软骨与耻骨后脂肪垫厚度(mm)。

诊断标准与关键数值

  • PFD > 6 mm 为原文引用的筛查参考值;耻骨软骨厚度均值 1.25 mm±0.58 mm、上限阈值 2.39 mm(+1.96σ);耻骨后脂肪垫厚度均值 2.67 mm±0.78 mm、上限阈值 4.20 mm(+1.96σ)。

临床应用与阅片要点

  • 作者认为,PFD 增宽由耻骨软骨 >2.39 mm 且不伴耻骨后脂肪垫增大(<4.20 mm)所致者,可仅随访而不过度治疗。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Screening modalities for Developmental Dysplasia of the Hip (DDH) and indications for treatment of mild forms remain controversial. Ultrasound (US) measurement of the pubofemoral distance (PFD > 6 mm, composed of the pubic cartilage and the pulvinar) can avoid late diagnoses of DDH. A thick pubic cartilage may nevertheless lead to false positives. The purpose of this study was to establish standard measurements of pubic cartilage and pulvinar, through universal US screening, to lower false positive results and thus any overtreatment.

METHODS: This is a single-center observational prospective study conducted from December 2016 to January 2018, on infants who underwent universal US screening for DDH. The only inclusion criterion was an adjusted age between 4 and 12 weeks when US was realized. PFD measurement was made using the Couture and Tréguier method. In addition, thicknesses of pubic cartilage and pulvinar were measured on the same US section, in millimeters.

RESULTS: Nine hundred and forty-eight patients, representing 1896 hips, were included. The average value of pubic cartilage thickness was 1.25 mm ± 0.58 mm, with an upper threshold of 2.39 mm (+1.96σ). The average value of pulvinar thickness was 2.67 mm ± 0.78 mm, with an upper threshold of 4.20 mm (+1.96σ). We found high inter-observer reproducibility in pubic cartilage measurements.

CONCLUSION: Systematic measurements of pubic cartilage and pulvinar may refine therapeutic decision by identifying false positives. Patients with increased PFD due to a thick pubic cartilage >2,39 mm, without an associated pulvinar enlargement (<4,20 mm), could be therefore only monitored and not overtreated.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Printemps C, Cousin I, Le Lez Soquet S, et al. Pulvinar and pubic cartilage measurements to refine universal ultrasound screening for developmental dysplasia of the hip: Data from 1896 infant hips. Eur J Radiol. 2021. PMID: 33930718. doi:10.1016/j.ejrad.2021.109727

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。