利用肿块特征频率与弹性预测浸润性乳腺癌及其与预后组织学特征和免疫组化生物标志物的相关性
本研究纳入264个活检证实的乳腺恶性肿块,评估剪切波弹性成像参数(包括新提出的肿块特征频率fmass)与预后组织学因素及免疫组化标志物的相关性。Emean、Emax、Emin、Esd与肿瘤大小、腋窝淋巴结状态、组织学亚型和免疫组化亚型显著相关;fmass与钙化、腋窝淋巴结状态、组织学分级、免疫组化标志物表达及亚型显著相关。结论认为不良预后因素与高剪切波弹性值及低fmass值相关,剪切波弹性成像可能有助于预测乳腺癌侵袭性。
要点
- 肿块特征频率fmass定义为感兴趣区内平均最小剪切波速度与肿块最大径的比值。
- Emean联合BI-RADS评分预测腋窝淋巴结状态的AUC为0.73(95%CI:0.67-0.80)。
- Emax联合BI-RADS评分预测腋窝淋巴结状态的AUC为0.75(95%CI:0.69-0.81)。
核心结论
- 不良预后因素与高剪切波弹性值和低肿块特征频率值相关。
- 剪切波弹性成像提供的有价值信息可能有助于预测乳腺癌侵袭性。
研究设计与样本
- 研究纳入264个活检证实的乳腺恶性肿块,评估剪切波弹性成像参数与预后组织学因素及免疫组化标志物的相关性。
关键影像表现/征象
- Emean、Emax、Emin、Esd与肿瘤大小、腋窝淋巴结状态、组织学亚型和免疫组化亚型显著相关。
- fmass与钙化存在、腋窝淋巴结状态、组织学分级、免疫组化标志物表达及免疫组化亚型显著相关。
诊断标准与关键数值
- fmass定义为感兴趣区内空间上平均最小剪切波速度与肿块最大径的比值。
- Emean联合BI-RADS评分预测腋窝淋巴结状态的AUC为0.73(95%CI:0.67-0.80)。
- Emax联合BI-RADS评分预测腋窝淋巴结状态的AUC为0.75(95%CI:0.69-0.81)。
临床应用与阅片要点
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
This purpose of this study is to correlate a new shear-wave elastography (SWE) parameter, mass characteristic frequency (fmass) and other elasticity measure with the prognostic histological factors and immunohistochemical (IHC) biomarkers for the evaluation of heterogeneous breast carcinomas. The new parameter, fmass, first introduced in this paper, is defined as the ratio of the averaged minimum shear wave speed taken spatially within regions of interest to the largest mass dimension. 264 biopsy-proven breast cancerous masses were included in this study. Mean (Emean), maximum (Emax), minimum (Emin) shear wave elasticity and standard deviation (Esd) of shear wave elasticity were found significantly correlated with tumor size, axillary lymph node (ALN) status, histological subtypes and IHC subtypes. The areas under the curve for the ALN prediction are 0.73 (95% confidence interval [CI]: 0.67-0.80) and 0.75 (95% CI: 0.69-0.81) for the combination of Emean with Breast Imaging Reporting and Data System (BI-RADS) score and Emax with BI-RADS score, respectively. fmass was significantly correlated with the presence of calcifications, ALN status, histological grade, the expressions of IHC biomarkers and IHC subtypes. To conclude, poor prognostic factors were associated with high shear wave elasticity values and low mass characteristic frequency value. Therefore, SWE provides valuable information that may help with prediction of breast cancer invasiveness.
引用
- Gu J, Polley EC, Boughey JC, et al. Prediction of Invasive Breast Cancer Using Mass Characteristic Frequency and Elasticity in Correlation with Prognostic Histologic Features and Immunohistochemical Biomarkers. Ultrasound Med Biol. 2021. PMID: 33994231. doi:10.1016/j.ultrasmedbio.2021.03.039
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。