PubMed 文献 · Radiology · 2021-05-04

该回顾性研究基于Córdoba断层合成筛查试验的15987次筛查配对独立阅读的DM和DBT影像,评估AI系统分诊策略与原始单读或双读设置相比的工作负荷、敏感度和召回率。与DBT双读相比,AI策略工作负荷降低72.5%(P<.001)、敏感度非劣(P=.38)、召回率降低16.7%(P<.001);与DM双读相比,AI联合DBT策略工作负荷降低29.7%、敏感度提高25.0%、召回率降低27.1%(均P<.001)。结论认为基于AI的筛查策略可将工作负荷降低最多70%。

要点

  • AI分诊策略在DBT筛查中与双读相比工作负荷降低72.5%,敏感度非劣,召回率降低16.7%。
  • AI联合DBT策略与DM双读相比工作负荷降低29.7%,敏感度提高25.0%,召回率降低27.1%。
  • AI系统对DM和DBT独立计算癌症风险评分,用于分诊最不可疑的检查免于人读。

核心结论

  • 基于人工智能系统的数字乳腺X线摄影和数字乳腺断层合成筛查策略可将工作负荷降低最多70%。

研究设计与样本

  • 回顾性评估,来自Córdoba断层合成筛查试验,连续收集2015年1月至2016年12月筛查配对独立阅读的DM和DBT影像,共15987次检查(15986名女性,平均年龄58岁±6),原始设置为DM或DBT单读或双读,AI系统独立计算癌症风险评分,模拟自主AI分诊策略与原始设置比较工作负荷、敏感度和召回率,采用McNemar检验及Bonferroni校正。

诊断标准与关键数值

  • 与DBT双读相比(需要568小时,检出113例癌症中的92例,15987次检查中706次召回),AI联合DBT策略工作负荷降低72.5%(P<.001,需要156小时),敏感度非劣(检出113例中的95例,P=.38),召回率降低16.7%(P<.001,15987次检查中588次召回)。
  • 与DM双读相比(需要222小时,检出113例中的76例,15987次检查中807次召回),AI联合DBT策略工作负荷降低29.7%(P<.001),敏感度提高25.0%(P<.001),召回率降低27.1%(P<.001)。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Background The workflow of breast cancer screening programs could be improved given the high workload and the high number of false-positive and false-negative assessments. Purpose To evaluate if using an artificial intelligence (AI) system could reduce workload without reducing cancer detection in breast cancer screening with digital mammography (DM) or digital breast tomosynthesis (DBT). Materials and Methods Consecutive screening-paired and independently read DM and DBT images acquired from January 2015 to December 2016 were retrospectively collected from the Córdoba Tomosynthesis Screening Trial. The original reading settings were single or double reading of DM or DBT images. An AI system computed a cancer risk score for DM and DBT examinations independently. Each original setting was compared with a simulated autonomous AI triaging strategy (the least suspicious examinations for AI are not human-read; the rest are read in the same setting as the original, and examinations not recalled by radiologists but graded as very suspicious by AI are recalled) in terms of workload, sensitivity, and recall rate. The McNemar test with Bonferroni correction was used for statistical analysis. Results A total of 15 987 DM and DBT examinations (which included 98 screening-detected and 15 interval cancers) from 15 986 women (mean age ± standard deviation, 58 years ± 6) were evaluated. In comparison with double reading of DBT images (568 hours needed, 92 of 113 cancers detected, 706 recalls in 15 987 examinations), AI with DBT would result in 72.5% less workload (P < .001, 156 hours needed), noninferior sensitivity (95 of 113 cancers detected, P = .38), and 16.7% lower recall rate (P < .001, 588 recalls in 15 987 examinations). Similar results were obtained for AI with DM. In comparison with the original double reading of DM images (222 hours needed, 76 of 113 cancers detected, 807 recalls in 15 987 examinations), AI with DBT would result in 29.7% less workload (P < .001), 25.0% higher sensitivity (P < .001), and 27.1% lower recall rate (P < .001). Conclusion Digital mammography and digital breast tomosynthesis screening strategies based on artificial intelligence systems could reduce workload up to 70%. Published under a CC BY 4.0 license.