文献速递乳腺乳腺X线

有与无乳房植入物女性的乳腺癌筛查:数字乳腺X线摄影与数字乳腺X线摄影联合数字乳腺断层合成摄影比较的回顾性研究

Breast cancer screening in women with and without implants: retrospective study comparing digital mammography to digital mammography combined with digital breast tomosynthesis.
PubMed 文献 · Eur Radiol · 2021-05-20

回顾性比较2011年2月至2017年3月有或无乳房植入物女性接受数字乳腺X线摄影(DM)或DM联合数字乳腺断层合成摄影(DM/DBT)筛查的表现指标。无植入物女性中,DM/DBT较DM显著降低召回率、提高癌症检出率和召回阳性预测值;有植入物女性中DM/DBT各指标呈相似改善趋势但均未达统计学显著。

要点

  • 无植入物女性:DM/DBT较DM显著降低召回率(8.53% vs 6.79%)、提高癌症检出率(3.96/1000 vs 5.12/1000)和召回阳性预测值(4.64% vs 7.54%)。
  • 有植入物女性:DM/DBT较DM召回率(5.81% vs 4.87%)、癌症检出率(2.49/1000 vs 2.92/1000)、召回阳性预测值(4.29% vs 6.0%)呈改善趋势但均未达统计学显著。
  • 有植入物女性DM/DBT各项指标改善趋势未达统计学显著,原文认为可能与样本量有关。

核心结论

  • 无植入物女性中,DM/DBT较单独DM显著改善召回率、癌症检出率和召回阳性预测值;有植入物女性中DM/DBT呈相似改善趋势但各指标均未达统计学显著。

研究设计与样本

  • 回顾性研究,2011年2月至2017年3月乳腺X线摄影,排除单侧植入物或既往乳腺癌13,201例后纳入有植入物女性6,041例和无植入物女性91,550例,患者可自行选择DM或DM/DBT筛查,采用卡方检验比较乳腺X线摄影表现指标。

诊断标准与关键数值

  • 无植入物女性:DM(n=113,973)召回率8.53%(9726/113,973),DM/DBT(n=61,896)召回率6.79%(4204/61,896),p<.001。
  • 无植入物女性:DM每1000次检查癌症检出率3.96(451/113,973),DM/DBT为5.12(317/61,896),p=.003。
  • 无植入物女性:DM召回阳性预测值4.64%(451/9726),DM/DBT为7.54%(317/4204),p<.001。
  • 有植入物女性:DM(n=6815)召回率5.81%(396/6815),DM/DBT(n=5138)召回率4.87%(250/5138),p=.158。
  • 有植入物女性:DM每1000次检查癌症检出率2.49(17/6815),DM/DBT为2.92(15/5138),p>0.999;DM召回阳性预测值4.29%(17/396),DM/DBT为6.0%(15/250),p>0.999。

临床应用与阅片要点

  • 无植入物女性筛查中,DM/DBT较单独DM显著降低召回率、提高癌症检出率和召回阳性预测值。
  • 有植入物女性筛查中,DM/DBT较单独DM的召回率、癌症检出率和召回阳性预测值呈改善趋势但未达统计学显著,原文认为可能与样本量有关。

局限性

  • 有植入物女性中DM/DBT各项指标改善趋势未达统计学显著,原文认为可能与样本量有关。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Compare four groups being screened: women without breast implants undergoing digital mammography (DM), women without breast implants undergoing DM with digital breast tomosynthesis (DM/DBT), women with implants undergoing DM, and women with implants undergoing DM/DBT.

METHODS: Mammograms from February 2011 to March 2017 were retrospectively reviewed after 13,201 were excluded for a unilateral implant or prior breast cancer. Patients had been allowed to choose between DM and DM/DBT screening. Mammography performance metrics were compared using chi-square tests.

RESULTS: Six thousand forty-one women with implants and 91,550 women without implants were included. In mammograms without implants, DM (n = 113,973) and DM/DBT (n = 61,896) yielded recall rates (RRs) of 8.53% and 6.79% (9726/113,973 and 4204/61,896, respectively, p < .001), cancer detection rates per 1000 exams (CDRs) of 3.96 and 5.12 (451/113,973 and 317/61,896, respectively, p = .003), and positive predictive values for recall (PPV1s) of 4.64% and 7.54% (451/9726 and 317/4204, respectively, p < .001), respectively. In mammograms with implants, DM (n = 6815) and DM/DBT (n = 5138) yielded RRs of 5.81% and 4.87% (396/6815 and 250/5138, respectively, p = .158), CDRs of 2.49 and 2.92 (17/6815 and 15/5138, respectively, p > 0.999), and PPV1s of 4.29% and 6.0% (17/396 and 15/250, respectively, p > 0.999), respectively.

CONCLUSIONS: DM/DBT significantly improved recall rates, cancer detection rates, and positive predictive values for recall compared to DM alone in women without implants. DM/DBT performance in women with implants trended towards similar improvements, though no metric was statistically significant.

KEY POINTS: • Digital mammography with tomosynthesis improved recall rates, cancer detection rates, and positive predictive values for recall compared to digital mammography alone for women without implants. • Digital mammography with tomosynthesis trended towards improving recall rates, cancer detection rates, and positive predictive values for recall compared to digital mammography alone for women with implants, but these trends were not statistically significant - likely related to sample size.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Cohen EO, Perry RE, Tso HH, et al. Breast cancer screening in women with and without implants: retrospective study comparing digital mammography to digital mammography combined with digital breast tomosynthesis. Eur Radiol. 2021. PMID: 34014380. doi:10.1007/s00330-021-08040-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。