剪切波弹性成像作为辅助工具检测腋窝淋巴结转移的诊断准确性
本研究评估剪切波弹性成像(SWE)在鉴别乳腺癌腋窝淋巴结良恶性中的诊断性能,对107例患者的乳腺病灶和腋窝行B型超声和SWE检查,以组织病理学为金标准。定性SWE的曲线下面积最高(81.3%),优于B型超声皮质增厚>3 mm(70.1%)和定量SWE Emax 15.2 kPa(61.2%)。定性SWE联合B型超声可提高转移性腋窝淋巴结的诊断准确性。
要点
- 定性SWE(彩色模式)诊断转移性腋窝淋巴结的AUC为81.3%,高于B型超声的70.1%和定量SWE的61.2%。
- 定性SWE联合B型超声(皮质厚度>3 mm)的敏感度71.6%、特异度95%、准确率80.4%。
- 定性SWE单独诊断的敏感度96.0%、特异度56.1%。
核心结论
- 定性SWE评估的准确性高于定量SWE,定性SWE作为B型超声的辅助手段可提高乳腺癌转移性腋窝淋巴结的诊断准确性。
研究设计与样本
- 研究纳入107例患者,对乳腺病灶和腋窝行B型超声和剪切波弹性成像(SWE)检查,以组织病理学为诊断金标准。
诊断标准与关键数值
- 转移性腋窝淋巴结中,定性SWE(彩色模式)的AUC为81.3%,B型超声(皮质增厚>3 mm)的AUC为70.1%,定量SWE(Emax 15.2 kPa)的AUC为61.2%。
- 定性SWE诊断转移性腋窝淋巴结的敏感度为96.0%,特异度为56.1%。
- B型超声(皮质厚度>3 mm为截断点)联合定性SWE(彩色模式2至4)诊断转移性腋窝淋巴结的敏感度71.6%、特异度95%、PPV 96%、NPV 66.7%、准确率80.4%。
局限性
- 原文未报告局限性
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: This study evaluates the diagnostic performance of shear wave elastography (SWE) in differentiating between benign and axillary lymph node (ALN) metastasis in breast carcinoma.
MATERIALS AND METHODS: Breast lesions and axillae of 107 patients were assessed using B-mode ultrasound and SWE. Histopathology was the diagnostic gold standard.
RESULTS: In metastatic axillary lymph nodes, qualitative SWE using color patterns had the highest area under curve (AUC) value, followed by B-mode Ultrasound (cortical thickening >3 mm) and quantitative SWE using Emax of 15.2 kPa (AUC of 81.3%, 70.1%, and 61.2%, respectively). Qualitative SWE exhibited better diagnostic performance than the other two parameters, with sensitivity of 96.0% and specificity of 56.1%. Combination of B-mode Ultrasound (using cortical thickness of >3 mm as cut-off point) and qualitative SWE (Color patterns of 2 to 4) showed sensitivity of 71.6%, specificity of 95%, PPV of 96%, NPV of 66.7%, and accuracy of 80.4%.
CONCLUSION: Qualitative SWE assessment exhibited higher accuracy compared to quantitative values. Qualitative SWE as an adjunct to B-mode ultrasound can further improve the diagnostic accuracy of metastatic ALN in breast cancer.
引用
- Ng WL, Omar N, Ab Mumin N, et al. Diagnostic Accuracy of Shear Wave Elastography as an Adjunct Tool in Detecting Axillary Lymph Nodes Metastasis. Acad Radiol. 2021. PMID: 33926793. doi:10.1016/j.acra.2021.03.018
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。