体积ADC直方图分析在术前评估子宫内膜癌组织学亚型与分级中的价值
本研究基于317例子宫内膜癌患者术前MRI数据,提取体积ADC直方图指标,评估其在鉴别子宫内膜样腺癌与浆液性癌及区分肿瘤分级中的价值。结果显示浆液性癌体积更大且ADC均值及高百分位数更低,G1与G2/G3子宫内膜样腺癌间多个ADC指标差异显著。体积ADC直方图有助于无创术前预测亚型并区分G1与G2/G3。
要点
- 肿瘤体积≥7.752 cm³提示浆液性癌,AUC为0.765。
- meanADC≥0.892×10⁻³ mm²/s可区分G1与G2/G3子宫内膜样腺癌,AUC为0.818。
- 浆液性癌较子宫内膜样腺癌体积更大、meanADC及50th/75th/90th百分位数更低。
核心结论
- 体积ADC直方图分析有助于无创术前预测子宫内膜癌组织学亚型,并区分G1与G2/G3子宫内膜样腺癌。
研究设计与样本
- 回顾性研究,纳入317例子宫内膜癌患者术前MRI数据集,提取体积ADC直方图指标,以病理为参考标准。
关键影像表现/征象
- 浆液性癌较子宫内膜样腺癌肿瘤体积显著更大(P<0.001),meanADC及50th、75th、90th百分位数ADC显著更低(均P<0.05)。
- G1子宫内膜样腺癌的minADC、maxADC、meanADC及10th至90th百分位数ADC均显著高于G2和G3(均P<0.05),而G2与G3间无显著差异(均P>0.05)。
临床应用与阅片要点
- 术前MRI测量肿瘤体积及ADC直方图指标(尤其meanADC和高百分位数)可辅助无创评估亚型与分级。
- 注意G2与G3子宫内膜样腺癌间ADC指标无显著差异,不宜单独用于区分这两级。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To assess the value of volumetric ADC histogram metrics in evaluating the histological subtype and grade of endometrial cancer.
METHOD: Preoperative MRI datasets of 317 patients with endometrial cancer were used to obtain volumetric ADC histogram metrics (tumour volume; minADC, maxADC and meanADC; 10th, 25th, 50th, 75th and 90th percentiles of ADC; skewness; and kurtosis). The Mann-Whitney test or Student's t-test was used to compare the difference in ADC histogram metrics between endometrioid adenocarcinomas (EACs) and serous endometrial cancers (SECs) and between different tumour grades (G1, G2, G3). The area under the curve (AUC) of the receiver operating characteristic (ROC) curve was used to evaluate the performance of ADC histogram metrics or combined models in predicting the tumour subtype and grade.
RESULTS: SECs showed a significantly larger tumour volume (P < 0.001) and lower meanADC, 50th, 75th and 90th percentiles of ADC than EACs (all P < 0.05). MinADC, maxADC, meanADC, 10th, 25th, 50th, 75th, 90th percentiles of ADC were significantly higher in G1 than in G2 and G3 EACs (all P < 0.05), while were not significantly different between G2 and G3 EACs (all P > 0.05). A tumour volume ≥ 7.752 cm3 allowed for the prediction of SECs, with an AUC of 0.765 (0.714-0.810). A meanADC ≥ 0.892 × 10-3 mm2/s enabled to discriminate G1 from G2 and G3 EACs, with an AUC of 0.818 (0.769-0.861).
CONCLUSION: Volumetric ADC histogram analysis is helpful for non-invasive preoperatively predicting the subtype of endometrial cancer and differentiating G1 from G2 and G3 EACs.
引用
- Ma X, Shen M, He Y, et al. The role of volumetric ADC histogram analysis in preoperatively evaluating the tumour subtype and grade of endometrial cancer. Eur J Radiol. 2021. PMID: 33962254. doi:10.1016/j.ejrad.2021.109745
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。