T2*加权MRI可提供可行的胎儿「黑骨」对比,效果优于现有序列

T2*-weighted MRI produces viable fetal "Black-Bone" contrast with significant benefits when compared to current sequences.
PubMed 文献 · Br J Radiol · 2021-05-21

本研究回顾性分析17例胎儿MRI,评估优化T2*加权GRE序列的「黑骨」对比图像质量,由四名盲法观察者用五分法评分。结果显示63%病例图像质量达合格至优秀,且同一患者中评分持续高于其他三种对比序列;图像质量与孕龄相关,26周后几乎全部患者获得良好图像质量。结论认为T2*加权GRE可提供 adequate 胎儿「黑骨」对比,效果不劣于文献其他序列,且运动伪影少、更易推广。

要点

  • T2*加权GRE序列在63%病例中提供合格至优秀的胎儿「黑骨」图像质量。
  • 同一患者内比较,T2*加权GRE评分持续高于其他三种对比序列。
  • 孕26周后几乎全部患者可获得良好图像质量,提示孕龄影响图像质量。

局限性

  • 回顾性研究,样本量仅17例。
  • 图像质量评分依赖四名观察者主观五分法,未报告观察者间一致性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: Fetal "black bone" MRI could be useful in the diagnosis of various skeletal conditions during pregnancy without exposure to ionizing radiation. Previously suggested susceptibility-weighted imaging (SWI) is not available in the suggested form on all scanners leading to long imaging times that are susceptible to motion artefacts. We aimed to assess if an optimized T2*-weighted GRE sequence can provide viable "black bone" contrast and compared it to other sequences in the literature.

METHODS: A retrospective study was conducted on 17 patients who underwent fetal MRI. Patients were imaged with an optimized T2*-weighted GRE sequence, as well as at least one other "black-bone" sequence. Image quality was scored by four blinded observers on a five-point scale.

RESULTS: The T2*-weighted GRE sequence offered adequate to excellent image quality in 63% of cases and scored consistently higher than the three other comparison sequences when comparing images from the same patient. Image quality was found to be dependent on gestational age with good image quality achieved on almost all patients after 26 weeks.

CONCLUSIONS: T2*-weighted GRE imaging can provide adequate fetal "black bone" contrast and performs at least as well as other sequences in the literature due to good bone to soft tissue contrast and minimal motion artefacts.

ADVANCES IN KNOWLEDGE: T2*-weighted fetal "black-bone" imaging can provide excellent bone to soft tissue contrast without using ionizing radiation. It is as good as other "black bone" sequences and may be simpler and more widely implemented, with less motion artefacts.

来源:Br J Radiol,查看原文。版权归原作者所有。

引用

  1. Goodall AF, Barrett A, Whitby E, et al. T2*-weighted MRI produces viable fetal "Black-Bone" contrast with significant benefits when compared to current sequences. Br J Radiol. 2021. PMID: 33989027. doi:10.1259/bjr.20200940